Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics B

An all-optical, high-sensitivity magnetic gradiometer

C. Affolderbach, Markus Stähler, Svenja A. Knappe, R. Wynands

Published Nov 1, 2002• 72 citations
Publisher
DOI
10.1007/s00340-002-0959-8

Related papers

Ultra high sensitivity quantum gravi-gradiometer

Joel Gomes Baptista, Valentin Cambier, Leonid A. Sidorenkov +2 more

•Jun 12, 2023•0 citations

Highly sensitive cold-atom gravity gradiometer

Xiangmin Wu, Tianteng Ma, Mingqi Huang +7 more

Physical Review Applied•Apr 16, 2026•1 citation

A new miniaturized atomic~magnetic~gradiometer

Dong Sheng, Abigail R. Perry, Sean Krzyzewski +3 more

Bulletin of the American Physical Society•May 27, 2016•0 citations

Quantum enhanced ultra high sensitivity gravi-gradiometer

Valentin Cambier, Joel Gomes Baptista, Leonid A. Sidorenkov +2 more

•Jun 18, 2023•0 citations

A femtotesla quantum-noise-limited pulsed gradiometer at Earth's magnetic fields

Vito Giovanni Lucivero, Won‐Jae Lee, Michael V. Romalis +3 more

Bulletin of the American Physical Society•May 28, 2019•0 citations

Single-beam highly sensitive magnetic field gradiometer based on the atomic spin-exchange relaxation-free effect

Yang Li, Yuxuan Ren, Huihui Zhai +3 more

This paper presents a single-beam atomic magnetic field measurement gradiometer, which is a highly sensitive magnetic field gradient measuring instrument based on the atom spin-exchange relaxation-free (SERF) effect. The reflective detection optical path structure is adopted. The spin precession signals of an atom under incident and reflected light are different. There is also a difference in the corresponding magnetic field distribution. The final measurement of magnetic field gradients is conducted based on the different magnetic field distributions. The single-beam high-sensitive magnetic field gradiometers based on the atomic SERF effect are more sensitive than conventional two-probe magnetic field gradiometers or two-beam magnetic field gradiometers. The gradiometers are not affected by a difference in the detected optical power in the single-beam detection light measurements. The reflector uses an angular cone prism for two-dimensional magnetic field gradient measurements and is simple to construct. The single-beam highly sensitive magnetic field gradient measurement instrument based on the atomic SERF effect has a reflective detection optical path structure. It uses a quarter-wave plate to achieve the initial signal phase elimination of both incident and reflected signal and an angular cone prism as a reflector to achieve two-dimensional measurement.

Applied Optics•Dec 6, 2021•4 citations
This paper presents a single-beam atomic magnetic field measurement gradiometer, which is a highly sensitive magnetic field gradient measuring instrument based on the atom spin-exchange relaxation-free (SERF) effect. The reflective detection optical path structure is adopted. The spin precession signals of an atom under incident and reflected light are different. There is also a difference in the corresponding magnetic field distribution. The final measurement of magnetic field gradients is conducted based on the different magnetic field distributions. The single-beam high-sensitive magnetic field gradiometers based on the atomic SERF effect are more sensitive than conventional two-probe magnetic field gradiometers or two-beam magnetic field gradiometers. The gradiometers are not affected by a difference in the detected optical power in the single-beam detection light measurements. The reflector uses an angular cone prism for two-dimensional magnetic field gradient measurements and is simple to construct. The single-beam highly sensitive magnetic field gradient measurement instrument based on the atomic SERF effect has a reflective detection optical path structure. It uses a quarter-wave plate to achieve the initial signal phase elimination of both incident and reflected signal and an angular cone prism as a reflector to achieve two-dimensional measurement.