Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physics Letters A

The gravitational phase-shift of a neutron wave-packet

Yoshinaga Takahashi

Published May 1, 1987• 2 citations
Publisher
DOI
10.1016/0375-9601(87)90481-6

Related papers

On the feasibility of a neutron Hanbury Brown—Twiss experiment with gravitationally-induced phase shift

Mark P. Silverman

Physics Letters A•Oct 1, 1988•5 citations

Observation of the phase shift of the neutron wave function under total reflection

N.K. Pleshanov

Physica B Condensed Matter•Apr 1, 1994•9 citations

Observation of the phase shift of the wave function of the neutron under total reflection

N.K. Pleshanov

•May 1, 1991•0 citations

Phase shifts and wave-packet displacements in neutron interferometry and a nondispersive, nondefocusing phase shifter

Hartmut Lemmel, Apoorva G. Wagh

A phase shifter in neutron interferometry creates not only a phase shift but also a spatial displacement of the neutron wave packet, leading to a reduced interference contrast. This wave-packet displacement constitutes a major hindrance in measuring large phase shifts. Here we present a nondispersive configuration with two identical phase shifters placed on one path in successive gaps of a symmetric triple Laue (LLL) interferometer. As compared to a single phase shifter, the dual phase shifter generates double the phase shift, yet a net null displacement of the wave packet. The interferometer thus remains fully focused however large the phase shift or the incident wavelength spread, permitting a white incident neutron beam as in the case of a purely topological phase measurement. Misalignment angles of a monolithic nondispersive dual phase shifter are equal and opposite in the two gaps. Its phase therefore remains nondispersive over a much wider angular range and attains a minimum magnitude at the correct orientation, obviating the need to alternate the phase shifter between the two interferometer paths during its alignment. The setup is hence ideally suited for measuring neutron coherent scattering lengths to ultrahigh precision.

Physical Review A•Sep 30, 2010•11 citations

Observation of Gravitational Bound Quantum States of the Neutron

S. Baeßler

APS•May 1, 2004•0 citations

Quantum States of Neutrons in the Gravitational Field

Claude Krantz

•Jan 1, 2006•5 citations
A phase shifter in neutron interferometry creates not only a phase shift but also a spatial displacement of the neutron wave packet, leading to a reduced interference contrast. This wave-packet displacement constitutes a major hindrance in measuring large phase shifts. Here we present a nondispersive configuration with two identical phase shifters placed on one path in successive gaps of a symmetric triple Laue (LLL) interferometer. As compared to a single phase shifter, the dual phase shifter generates double the phase shift, yet a net null displacement of the wave packet. The interferometer thus remains fully focused however large the phase shift or the incident wavelength spread, permitting a white incident neutron beam as in the case of a purely topological phase measurement. Misalignment angles of a monolithic nondispersive dual phase shifter are equal and opposite in the two gaps. Its phase therefore remains nondispersive over a much wider angular range and attains a minimum magnitude at the correct orientation, obviating the need to alternate the phase shifter between the two interferometer paths during its alignment. The setup is hence ideally suited for measuring neutron coherent scattering lengths to ultrahigh precision.