Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Terahertz Science and Technology

Quantum Efficiency of Cold Electron Bolometer Optical Response

Michael A. Tarasov, Valerian S. Edelman, Andrey B. Ermakov, Sumedh Mahashabde, L. S. Kuzmin

Published Jan 1, 2014• 12 citations
Publisher

Abstract

In this paper, we present the measurements of optical response dependence on power load of a Cold Electron Bolometer integrated in a twin slot antenna. These measurements are also compared to the models of the bolometer limit and the photon counter limit. The responsivity of 0.22*109V/W was measured at 0.22 pW radiation power from a black body at 3.5 K. According to our estimations, for optimized device the voltage responsivity at 100 mK electron temperature can approach S v = 1010V/W for power load below 0.1 pW and decreases down to 107V/W at 300 mK for 5 pW signal power in a sample with absorber volume of 5*10-20m3. In the case of low bath temperatures and high applied RF power the changes of tunneling current, dynamic resistance and voltage response are explained by non-thermal energy distribution of excited electrons. Distribution of excited electrons in such system at lower temperatures can be of non-Fermi type, hot electrons with energies of the order of 1 K tunnel from normal metal absorber to superconductor instead of relaxing down to thermal energy kTein absorber before tunneling. This effect can reduce quantum efficiency of the bolometer at 350 GHz from η = hf/kTph> 100 in ideal case down to single electron per absorbed photon ( η = 1) in the high power case. Methods of preserving high quantum efficiency are discussed.

DOI
10.1109/tthz.2014.2379331

Related papers

Power load dependencies of cold electron bolometer optical response at 350 ghz

Michael A. Tarasov, Valeryan S. Edel'man, Andrey B. Ermakov +2 more

Cold electron bolometers integrated with twin-slot antennas have been designed and fabricated. Optical response was measured in 0.06-0.6 K temperature range using black body radiation source at temperature 2-15 K. The responsivity of 0.3109 V/W was measured at 2.7 K radiation temperature. The estimated ultimate dark responsivity at 100 mK can approach Sv=1010 V/W and reduces down to 1.1108 V/W at 300 mK for the sample with absorber volume of 510-20 m3. At high power load levels and low temperatures the changes of tunneling current, dynamic resistance and voltage response have been explained by non-thermal energy distribution of excited electrons. Distribution of excited electrons in such system is of none-Fermi type, electrons with energies of the order of 1 K tunnel from normal metal absorber to superconductor instead of relaxing down to thermal energy kTe. This effect can reduce quantum efficiency of bolometer from hf/kTph in ideal case down to single electron per signal quantum in the high power case.

•Jan 1, 2014•0 citations

Optical Response of a Cold-Electron Bolometer Array Integrated in a 345-GHz Cross-Slot Antenna

Michael A. Tarasov, L. S. Kuzmin, Valerian S. Edelman +2 more

Two series/parallel arrays of ten cold-electron bolometers with superconductor-insulator-normal tunnel junctions were integrated in orthogonal ports of a cross-slot antenna. To increase the dynamic range of the receiver, all single bolometers in an array are connected in parallel for the microwave signal by capacitive coupling. To increase the output response, bolometers are connected in series for dc bias. With the measured voltage-to-temperature response of 8.8 μV/mK, absorber volume of 0.08 μm3, and output noise of about 10 nV/Hz1/2, we estimated the dark electrical noise equivalent power (NEP) as NEP = 6 * 10-18W/Hz1/2. The optical response down to NEP = 2 * 10-17W/Hz1/2was measured using a hot/cold load as a radiation source and a sample temperature down to 100 mK. The fluctuation sensitivity to the radiation source temperature is 1.3 * 10-4K/Hz1/2. A dynamic range over 43 dB was measured using a backward-wave oscillator, a variable polarization grid attenuator, and cold filters/attenuators.

IEEE Transactions on Applied Superconductivity•Oct 28, 2011•37 citations

Electrical and optical properties of a bolometer with a suspended absorber and tunneling-current thermometers

Michael A. Tarasov, Valeryan S. Edel'man, Sumedh Mahashabde +6 more

We have developed a bolometer with a suspended normal-metal absorber connected to superconducting leads via tunneling barriers. Such an absorber has reduced heat losses to the substrate, which greatly increases the responsivity of the bolometer to over 109 V/W at 75 mK when measured by dc Joule heating of the absorber. For high-frequency experiments, the bolometers have been integrated in planar twin-slot and log-periodic antennas. At 300 GHz and 100 mK, the bolometer demonstrates the voltage and current response of 3 × 108 V/W and 1.1 × 104 A/W, respectively, corresponding to the quantum efficiency of ∼15 electrons per photon. An effective thermalization of electrons in the absorber favors the high quantum efficiency. We also report on how the in-plane- and transverse magnetic fields influence the device characteristics.

Applied Physics Letters•Jun 12, 2017•8 citations

SINIS bolometer with a suspended absorber

Michael A. Tarasov, Valeryan S. Edel'man, Sumedh Mahashabde +6 more

We have developed a Superconductor-Insulator-Normal Metal-Insulator-Superconductor (SINIS) bolometer with a suspended normal metal bridge. The suspended bridge acts as a bolometric absorber with reduced heat losses to the substrate. Such bolometers were characterized at 100-350 mK bath temperatures and electrical responsivity of over 10 9 V/W was measured by dc heating the absorber through additional contacts. Suspended bolometers were also integrated in planar twin-slot and log-periodic antennas for operation in the submillimetre-band of radiation. The measured voltage response to radiation at 300 GHz and at 100 mK bath temperature is 3*10 8 V/W and a current response is 1.1*10 4 A/W which corresponds to a quantum efficiency of ~15 electrons per photon. An important feature of such suspended bolometers is the thermalization of electrons in the absorber heated by optical radiation, which in turn provides better quantum efficiency. This has been confirmed by comparison of bolometric response to dc and rf heating. We investigate the performance of direct SN traps and NIS traps with a tunnel barrier between the superconductor and normal metal trap. Increasing the volume of superconducting electrode helps to reduce overheating of superconductor. Influence of Andreev reflection and Kapitza resistance, as well as electron-phonon heat conductivity and thermal conductivity of N-wiring are estimated for such SINIS devices.

Journal of Physics Conference Series•Mar 1, 2018•2 citations

Non-Thermal Absorption and Quantum Efficiency of SINIS Bolometer

Michael A. Tarasov, Aleksandra A. Gunbina, Renat A. Yusupov +7 more

We study mechanisms of absorption in two essentially different types of superconductor-insulator-normal metal-insulator-superconductor (SINIS) bolometers with absorber directly placed on Si wafer and with absorber suspended above the substrate. The figure of merit for quantum photon absorption is quantum efficiency equal to the number of detected electrons for one photon. The efficiency of absorption is dramatically dependent on phonon losses to substrate and electrodes, and electron energy losses to electrodes through tunnel junctions. The maximum quantum efficiency can approachn=hf/kT= 160 at f = 350 GHz T = 0.1 K, and current responsivity dI/dP=e/kTin quantum gain bolometer case, contrary to photon counter mode with quantum efficiency of n = 1 and responsivity dI/dP=e/hf. In experiments, we approach intrinsic quantum efficiency up to n = 80 electrons per photon in bolometer with suspended absorber, contrary to quantum efficiency of about one for absorber on the substrate. In the case of suspended Cu and Pd absorber, Kapitsa resistance protect from power leak to Al electrodes.

IEEE Transactions on Applied Superconductivity•Feb 5, 2021•5 citations

Optical response of a titanium-based cold-electron bolometer

Ernst Otto, Michael A. Tarasov, Paul Grimes +3 more

We present experimental results on the testing of cold-electron bolometer (CEB) detectors comprised of a thin Ti film absorber and two SIN junctions integrated with a planar antenna. The CEB performance was tested in a He-3 sorption cryostat HELIOX-AC-V at bath temperatures of 280-305 mK. The optical response was measured using the hot/cold load method by flipping a Cu reflector opposite a blackbody surface inside a 3 K shield and using a thermal source with variable temperature. In the first experiment, the detector chip was mounted in an optical sample-holder whose aperture was switched towards or away from a blackbody source changing the incident radiation temperature from 3 K to 270 mK. As a result, we measured the optical response to a 3 K/270 mK radiation temperature change. The measured voltage response value for the detector integrated in a double-dipole antenna was Delta V-out = 120 mu V. This corresponds to a noise equivalent power of NEP = V-n/(dV/dP) = 3.5 x 10(-17) W Hz(-1/2), where dV/dP is the voltage to power response obtained from the incoming power estimation based on the Planck formula.

Superconductor Science and Technology•Jul 4, 2013•4 citations
In this paper, we present the measurements of optical response dependence on power load of a Cold Electron Bolometer integrated in a twin slot antenna. These measurements are also compared to the models of the bolometer limit and the photon counter limit. The responsivity of 0.22109V/W was measured at 0.22 pW radiation power from a black body at 3.5 K. According to our estimations, for optimized device the voltage responsivity at 100 mK electron temperature can approach S v = 1010V/W for power load below 0.1 pW and decreases down to 107V/W at 300 mK for 5 pW signal power in a sample with absorber volume of 510-20m3. In the case of low bath temperatures and high applied RF power the changes of tunneling current, dynamic resistance and voltage response are explained by non-thermal energy distribution of excited electrons. Distribution of excited electrons in such system at lower temperatures can be of non-Fermi type, hot electrons with energies of the order of 1 K tunnel from normal metal absorber to superconductor instead of relaxing down to thermal energy kTein absorber before tunneling. This effect can reduce quantum efficiency of the bolometer at 350 GHz from η = hf/kTph> 100 in ideal case down to single electron per absorbed photon ( η = 1) in the high power case. Methods of preserving high quantum efficiency are discussed.
Cold electron bolometers integrated with twin-slot antennas have been designed and fabricated. Optical response was measured in 0.06-0.6 K temperature range using black body radiation source at temperature 2-15 K. The responsivity of 0.3109 V/W was measured at 2.7 K radiation temperature. The estimated ultimate dark responsivity at 100 mK can approach Sv=1010 V/W and reduces down to 1.1108 V/W at 300 mK for the sample with absorber volume of 510-20 m3. At high power load levels and low temperatures the changes of tunneling current, dynamic resistance and voltage response have been explained by non-thermal energy distribution of excited electrons. Distribution of excited electrons in such system is of none-Fermi type, electrons with energies of the order of 1 K tunnel from normal metal absorber to superconductor instead of relaxing down to thermal energy kTe. This effect can reduce quantum efficiency of bolometer from hf/kTph in ideal case down to single electron per signal quantum in the high power case.
Two series/parallel arrays of ten cold-electron bolometers with superconductor-insulator-normal tunnel junctions were integrated in orthogonal ports of a cross-slot antenna. To increase the dynamic range of the receiver, all single bolometers in an array are connected in parallel for the microwave signal by capacitive coupling. To increase the output response, bolometers are connected in series for dc bias. With the measured voltage-to-temperature response of 8.8 μV/mK, absorber volume of 0.08 μm3, and output noise of about 10 nV/Hz1/2, we estimated the dark electrical noise equivalent power (NEP) as NEP = 6 * 10-18W/Hz1/2. The optical response down to NEP = 2 * 10-17W/Hz1/2was measured using a hot/cold load as a radiation source and a sample temperature down to 100 mK. The fluctuation sensitivity to the radiation source temperature is 1.3 * 10-4K/Hz1/2. A dynamic range over 43 dB was measured using a backward-wave oscillator, a variable polarization grid attenuator, and cold filters/attenuators.
We have developed a bolometer with a suspended normal-metal absorber connected to superconducting leads via tunneling barriers. Such an absorber has reduced heat losses to the substrate, which greatly increases the responsivity of the bolometer to over 109 V/W at 75 mK when measured by dc Joule heating of the absorber. For high-frequency experiments, the bolometers have been integrated in planar twin-slot and log-periodic antennas. At 300 GHz and 100 mK, the bolometer demonstrates the voltage and current response of 3 × 108 V/W and 1.1 × 104 A/W, respectively, corresponding to the quantum efficiency of ∼15 electrons per photon. An effective thermalization of electrons in the absorber favors the high quantum efficiency. We also report on how the in-plane- and transverse magnetic fields influence the device characteristics.
We have developed a Superconductor-Insulator-Normal Metal-Insulator-Superconductor (SINIS) bolometer with a suspended normal metal bridge. The suspended bridge acts as a bolometric absorber with reduced heat losses to the substrate. Such bolometers were characterized at 100-350 mK bath temperatures and electrical responsivity of over 10 9 V/W was measured by dc heating the absorber through additional contacts. Suspended bolometers were also integrated in planar twin-slot and log-periodic antennas for operation in the submillimetre-band of radiation. The measured voltage response to radiation at 300 GHz and at 100 mK bath temperature is 3*10 8 V/W and a current response is 1.1*10 4 A/W which corresponds to a quantum efficiency of ~15 electrons per photon. An important feature of such suspended bolometers is the thermalization of electrons in the absorber heated by optical radiation, which in turn provides better quantum efficiency. This has been confirmed by comparison of bolometric response to dc and rf heating. We investigate the performance of direct SN traps and NIS traps with a tunnel barrier between the superconductor and normal metal trap. Increasing the volume of superconducting electrode helps to reduce overheating of superconductor. Influence of Andreev reflection and Kapitza resistance, as well as electron-phonon heat conductivity and thermal conductivity of N-wiring are estimated for such SINIS devices.
We study mechanisms of absorption in two essentially different types of superconductor-insulator-normal metal-insulator-superconductor (SINIS) bolometers with absorber directly placed on Si wafer and with absorber suspended above the substrate. The figure of merit for quantum photon absorption is quantum efficiency equal to the number of detected electrons for one photon. The efficiency of absorption is dramatically dependent on phonon losses to substrate and electrodes, and electron energy losses to electrodes through tunnel junctions. The maximum quantum efficiency can approachn=hf/kT= 160 at f = 350 GHz T = 0.1 K, and current responsivity dI/dP=e/kTin quantum gain bolometer case, contrary to photon counter mode with quantum efficiency of n = 1 and responsivity dI/dP=e/hf. In experiments, we approach intrinsic quantum efficiency up to n = 80 electrons per photon in bolometer with suspended absorber, contrary to quantum efficiency of about one for absorber on the substrate. In the case of suspended Cu and Pd absorber, Kapitsa resistance protect from power leak to Al electrodes.
We present experimental results on the testing of cold-electron bolometer (CEB) detectors comprised of a thin Ti film absorber and two SIN junctions integrated with a planar antenna. The CEB performance was tested in a He-3 sorption cryostat HELIOX-AC-V at bath temperatures of 280-305 mK. The optical response was measured using the hot/cold load method by flipping a Cu reflector opposite a blackbody surface inside a 3 K shield and using a thermal source with variable temperature. In the first experiment, the detector chip was mounted in an optical sample-holder whose aperture was switched towards or away from a blackbody source changing the incident radiation temperature from 3 K to 270 mK. As a result, we measured the optical response to a 3 K/270 mK radiation temperature change. The measured voltage response value for the detector integrated in a double-dipole antenna was Delta V-out = 120 mu V. This corresponds to a noise equivalent power of NEP = V-n/(dV/dP) = 3.5 x 10(-17) W Hz(-1/2), where dV/dP is the voltage to power response obtained from the incoming power estimation based on the Planck formula.