Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics B

A quantum sensor for high-performance mass spectrometry

Daniel Rodríguez

Published Nov 26, 2011• 33 citations
Publisher
DOI
10.1007/s00340-011-4824-5

Related papers

Quantum sensors and measurements

Soumyajit Mandal

Elsevier eBooks•Jun 20, 2025•0 citations

Interferometric Mass Spectrometry

Radu Ionicioiu

Accelerator mass spectrometry (AMS) is a widely used technique with multiple applications, including geology, molecular biology, and archeology. In order to achieve a high dynamic range, AMS requires tandem accelerators and large magnets, which thus confines it to big laboratories. Here we propose interferometric mass spectrometry (Interf-MS), a novel method of mass separation which uses quantum interference. Interf-MS employs the wave-like properties of the samples and as such is complementary to AMS, in which samples are particle-like. This complementarity has two significant consequences: (i) in Interf-MS separation is performed according to the absolute mass m, and not to the mass-to-charge ratio m / q, as in AMS; (ii) in Interf-MS the samples are in the low-velocity regime, in contrast to the high-velocity regime used in AMS. Potential applications of Interf-MS are compact devices for mobile applications, sensitive molecules that break at the acceleration stage and neutral samples which are difficult to ionize.

arXiv:2107.04256•Journal of the American Society for Mass Spectrometry•May 20, 2023•3 citations

New Fields Opened Up by Superconducting Detector Technology

Nobuyuki Yoshikawa

Recent developments and their applications of superconducting detectors that directly detect the incidence of photons and particles will be reviewed. Transition-edge sensors, superconducting single-photon detectors and superconducting stripline sensors are included in this category. Their recent progresses in new application fields, such as quantum information communication and time-of-flight mass spectrometry, will be shown.

IEEJ Transactions on Fundamentals and Materials•Jan 1, 2011•0 citations

Quantum sensors: principles and ground applications

Franck Pereira dos Santos

•Mar 12, 2024•0 citations

Quantum Sensors

Science•Feb 8, 1974•0 citations

Dynamics of an unbalanced two-ion crystal in a Penning trap for application in optical mass spectrometry

M. J. Gutiérrez, J. Berrocal, Francisco Domínguez +4 more

In this paper, the dynamics of an unbalanced two-ion crystal comprising the ``target'' and the ``sensor'' ions confined in a Penning trap along the magnetic-field axis has been studied. First, the low amplitude regime is addressed. In this regime, the overall potential including the Coulomb repulsion between the ions can be considered harmonic and the axial, magnetron, and reduced-cyclotron modes split up into the so-called stretch and common modes, that are generalizations of the well-known ``breathing'' and ``center-of-mass'' motions of a balanced crystal made of two ions. By using optical detection to measure the frequencies of the modes of the crystal, and of the sensor ion on its own, in the quantum regime of motion, it will be possible to determine the target ion's free-cyclotron frequency. The nonharmonicity of the Coulomb interaction is also discussed since this causes large systematic effects, which are minimized due to the high sensitivity of the optical detection method when the crystal is cooled to the ground state of motion in the Penning trap.

arXiv:1907.08045•Physical Review A•Dec 10, 2019•18 citations
Accelerator mass spectrometry (AMS) is a widely used technique with multiple applications, including geology, molecular biology, and archeology. In order to achieve a high dynamic range, AMS requires tandem accelerators and large magnets, which thus confines it to big laboratories. Here we propose interferometric mass spectrometry (Interf-MS), a novel method of mass separation which uses quantum interference. Interf-MS employs the wave-like properties of the samples and as such is complementary to AMS, in which samples are particle-like. This complementarity has two significant consequences: (i) in Interf-MS separation is performed according to the absolute mass m, and not to the mass-to-charge ratio m / q, as in AMS; (ii) in Interf-MS the samples are in the low-velocity regime, in contrast to the high-velocity regime used in AMS. Potential applications of Interf-MS are compact devices for mobile applications, sensitive molecules that break at the acceleration stage and neutral samples which are difficult to ionize.
In this paper, the dynamics of an unbalanced two-ion crystal comprising the ``target'' and the ``sensor'' ions confined in a Penning trap along the magnetic-field axis has been studied. First, the low amplitude regime is addressed. In this regime, the overall potential including the Coulomb repulsion between the ions can be considered harmonic and the axial, magnetron, and reduced-cyclotron modes split up into the so-called stretch and common modes, that are generalizations of the well-known ``breathing'' and ``center-of-mass'' motions of a balanced crystal made of two ions. By using optical detection to measure the frequencies of the modes of the crystal, and of the sensor ion on its own, in the quantum regime of motion, it will be possible to determine the target ion's free-cyclotron frequency. The nonharmonicity of the Coulomb interaction is also discussed since this causes large systematic effects, which are minimized due to the high sensitivity of the optical detection method when the crystal is cooled to the ground state of motion in the Penning trap.