Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Pump-probe spectroscopy in degenerate two-level atoms with arbitrarily strong fields

T. Zigdon, A. D. Wilson‐Gordon, Chana Goren, M. Rosenbluh, Harry Friedmann

Published Mar 2, 2007• 2 citations
Publisher

Abstract

We review our previous work on pump-probe spectroscopy in realistic degenerate two-level systems and model systems. In particular, we discuss the role of transfer of coherence (TOC) between the ground and excited hyperfine states in producing electromagnetically-induced transparency (EIA) peaks in the probe spectrum, when an Fg goes to Fe = Fg +1 transition in an alkali-metal atom interacts with a strong pump and weak probe that have perpendicular polarizations. When the pump is rho+ polarized and the probe pi polarized, this system can be modelled by an N system. We also discuss the role of transfer of population (TOP) between the Zeeman levels of the ground hyperfine state in producing EIA peaks when the pump and probe have the same polarization. This system can be modelled using a double two-level system. The role of Doppler broadening and phase-changing collisions in modifying the EIA-TOC and EIA-TOP absorption and refraction spectra is also discussed. All these spectra were calculated using MATLAB programs that both construct and solve the relevant Bloch equations. In our recent work, we consider the effect of a strong probe on the pump absorption and refraction spectra when the pump and probe polarizations are linear and perpendicular. It is difficult to solve this problem numerically due to the large number frequencies involved. In order to simplify the problem, we considered two cases: (i) rho+ polarized pump and pi polarized probe, and (ii) rho+ polarized pump and rho- polarized probe, and investigated a series of transitions in both Rb and Cs, using modified versions of the MATLAB programs devised for the weakprobe case. A number of interesting differences from the weak-probe case were found. For example, when the probe is sufficiently strong, we found the pump and probe spectra to show complementary behavior. In addition, as the number of Zeeman levels increase, the EIA peaks become progressively sharper, and are accompanied by steeper dispersion.

DOI
10.1117/12.726791

Related papers

Electromagnetically induced absorption due to transfer of coherence and to transfer of population

Chana Goren, A. D. Wilson‐Gordon, M. Rosenbluh +1 more

The absorption spectrum of a weak probe, interacting with a driven degenerate two-level atomic system, whose ground and excited hyperfine states are ${\mathrm{F}}_{g,e},$ can exhibit narrow peaks at line center. When the pump and probe polarizations are different, ${F}_{e}{=F}_{g}+1$ and ${F}_{g}>0,$ the electromagnetically induced absorption (EIA) peak has been shown to be due to the transfer of coherence (TOC) between the excited and ground states via spontaneous decay. We give a detailed explanation of why the TOC that leads to EIA (EIA-TOC) can only take place when ground-state population trapping does not occur, that is, when ${F}_{e}{=F}_{g}+1.$ We also explain why EIA-TOC is observed in open systems. We show that EIA can also occur when the pump and probe polarizations are identical and ${F}_{e}{=F}_{g}+1.$ This EIA is analogous to an effect that occurs in simple two-level systems when the collisional transfer of population (TOP) from the ground state to a reservoir is greater than that from the excited state. For a degenerate two-level system, the reservoir consists of the Zeeman sublevels of the ground hyperfine state, and of other nearby hyperfine states that do not interact with the pump. We will also discuss the four-wave mixing spectrum under the conditions where EIA-TOC and EIA-TOP occur.

Physical Review A•Mar 21, 2003•155 citations

Pump-probe spectroscopy in degenerate two-level atoms with arbitrarily strong fields

T. Zigdon, A. D. Wilson‐Gordon, Harry Friedmann

We study the pump and probe absorption spectra, as a function of the probe detuning, in a degenerate two-level atomic system, for the case where the probe intensity is high enough to affect the pump absorption. The theory is valid for any ${F}_{g}\ensuremath{\rightarrow}{F}_{e}$ alkali-metal transition interacting with an arbitrarily intense pump and probe (with general Rabi frequencies ${\ensuremath{\Omega}}_{1,2}$) which are perpendicularly polarized with either ${\ensuremath{\sigma}}_{\ifmmode\pm\else\textpm\fi{}}$ or $\ensuremath{\pi}$ polarization. We have constructed a computer program that can calculate the spectra without requiring one to write out the Bloch equations explicitly. We show that, when the pump is ${\ensuremath{\sigma}}_{\ifmmode\pm\else\textpm\fi{}}$ polarized and the probe $\ensuremath{\pi}$ polarized, or vice versa, the pump and probe absorptions depend on the Zeeman coherences between the nearest-neighboring ground or excited Zeeman sublevels, whereas when the pump is ${\ensuremath{\sigma}}_{+}$ polarized and the probe ${\ensuremath{\sigma}}_{\ensuremath{-}}$ polarized, or vice versa, the Zeeman coherences that directly determine the absorption are between next-nearest neighbors. We report calculations of the pump and probe absorption spectra for the cycling ${F}_{g}=2\ensuremath{\rightarrow}{F}_{e}=3$ transition in the ${D}_{2}$ line of $^{87}\text{R}\text{b}$, interacting with a resonant ${\ensuremath{\sigma}}_{+}$-polarized pump and either a $\ensuremath{\pi}$- or a ${\ensuremath{\sigma}}_{\ensuremath{-}}$- polarized probe. The probe and pump absorption spectra are analyzed by considering the contributions that derive from the individual ${m}_{g}\ensuremath{\rightarrow}{m}_{e}$ transitions. We then show how these contributions depend on the ground- and excited-state populations and Zeeman coherences, and investigate the role played by transfer of coherence from the excited to the ground hyperfine state. We show that the pump and probe absorption spectra are mirror images of each other when ${\ensuremath{\Omega}}_{1}\ensuremath{\ge}{\ensuremath{\Omega}}_{2}>\ensuremath{\Gamma}$, and have the same behavior at line center and complementary behavior in the wings, when ${\ensuremath{\Omega}}_{1}\ensuremath{\ge}{\ensuremath{\Omega}}_{2}<\ensuremath{\Gamma}$ ($\ensuremath{\Gamma}$ is the rate of spontaneous decay from ${F}_{e}$ to ${F}_{g}$).

Physical Review A•Mar 19, 2008•18 citations

Electromagnetically induced absorption due to transfer of population in degenerate two-level systems

Chana Goren, A. D. Wilson‐Gordon, M. Rosenbluh +1 more

We predict the occurrence of electromagnetically induced absorption (EIA) in cycling degenerate two-level transitions where ${F}_{e}={F}_{g}+1$ and ${F}_{g}>0$, interacting with pump and probe lasers with the same polarization. The EIA is due to transfer of population (TOP) between the Zeeman levels of the ground hyperfine state, rather than transfer of coherence (TOC) which occurs for perpendicularly polarized lasers. We model EIA-TOP using a double two-level system (TLS) which we compare with the four-level $N$ system, which models EIA-TOC. When the pump intensity is low, both models give an EIA peak at line center. The effect of introducing phase-changing collisions is studied, in the presence and absence of Doppler broadening, for both the double TLS and $N$ systems. In the presence of phase-changing collisions, the central EIA peaks are narrowed in both models and persist to higher pump Rabi frequencies than in the absence of collisions. In the double TLS, in the presence of Doppler broadening, the central EIA-TOP peak becomes narrower and does not develop a dip in its center, in contrast to the $N$ system. The central dip that appears in the Doppler-broadened EIA-TOC spectrum can be wiped out by adding phase-changing collisions. We demonstrate that EIA-TOP can be obtained for realistic atomic transitions interacting with lasers that have the same polarization.

Physical Review A•Oct 21, 2004•34 citations

Atomic four-level N systems

Chana Goren, A. D. Wilson‐Gordon, M. Rosenbluh +1 more

We investigate the atomic four-level $N$ configuration both analytically and numerically, for various pump and probe intensities, with and without transfer of coherence (TOC) and Doppler broadening, and compare the results obtained to those of realistic atomic systems. We find that TOC affects the whole spectrum, in addition to producing an electromagnetically induced absorption (EIA) peak at line center. We show that the EIA peak splits as the pump intensity increases. These results are compared with those of realistic systems. When the pump is ${\ensuremath{\sigma}}^{+}$ polarized and the probe is $\ensuremath{\pi}$ polarized, the results are similar to those of the $N$ configuration. When the pump and probe polarizations are both linear with perpendicular polarizations, various $N$-like subsystems contribute to the spectrum. Consequently, the splitting of the EIA peak only occurs at very high pump intensities. We also discuss the influence of the probe on the pump absorption and refraction and find that both the pump and probe show EIA peaks when the pump intensity is low, and complementary behavior when the pump is intense. At both low and high pump intensity, the pump and probe dispersions are of opposite sign.

Physical Review A•May 26, 2004•102 citations

Simulation of double electromagnetically induced transparency in a four-level V-type system: A comparative study of probe and pump transmissions

Rohit Hazra, Md. Mabud Hossain

In this paper, we present the theoretical study of double electromagnetically induced transparency (EIT) in a four-level V-type system which is formed by two co-propagating laser fields and the Zeeman sublevels of hyperfine transitions of 87Rb D2 line. The density matrix equations for the four-level V-type system are derived from the Liouville’s equation of motion and numerically solved under steady state condition to get the EIT signals. We consider both the probe and pump transmission spectra for the observation of double EIT signals under both Doppler free and Doppler broadened conditions. In case of Doppler free medium, two EIT peaks are formed in the two Lorentzian shape dips present in the both Doppler free probe and pump transmission spectra. When the medium becomes Doppler broadened, the two EIT peaks are formed in the probe transmission spectrum having Doppler broadened background, but the pump transmission spectrum gives two EIT peaks in the Doppler free background. The effect of probe intensity variation on the two EIT peaks is studied in case of Doppler broadened probe transmission spectrum. It is found that the heights of the EIT peaks decrease as the probe intensity increases, and interestingly one EIT peak converts into EIA (electromagnetically induced absorption) dip at some strong probe intensity value. The depth of the EIA dip is significantly increased as the intensity of the probe field increases. We also present the effect of probe intensity variation on the EIT peaks in the pump transmission spectrum and found that the EIT peak heights are increased as the probe intensity increases.

AIP conference proceedings•Jan 1, 2019•3 citations

Unravelling the Mechanisms of Electromagnetically Induced Absorption and Transparency in Open Degenerate Multilevel System: Effects of Neighboring Transitions

Zeeshan Ali Safdar Jadoon, Heung‐Ryoul Noh, Jin‐Tae Kim

Abstract Optical Bloch equations with and without neighboring hyperfine states near the degenerate two-level system (DTLS) in the challenging case of 85Rb D2 transition that involves the Doppler broadening effect are solved herein. The calculated spectra agree well with the experimental results obtained using the coupling-probe scheme with orthogonal linear polarizations of the coupling and probe fields. The mechanisms of electromagnetically induced absorption (electromagnetically induced transparency) for the open Fg = 3 → Fe = 2 and 3 transitions (open Fg = 2 → Fe = 2 and 3 transitions) are clearly determined to be the effect of the strong closed Fg = 3 → Fe = 4 transition line (strong closed Fg = 2 → Fe = 1 transition line) based on the comparisons of the calculated absorption profiles of a DTLS without neighboring states and those of all levels with neighboring states depending on the coupling and probe power ratios. The crucial factors established based on comparisons of the calculated absorption profiles of DTLS with and without neighboring states, which enhance or reduce coherence effects and result in transformation between electromagnetically induced absorption and electromagnetically induced transparency, are the power ratios between coupling and probe beams, openness of the excited state, and effects of the neighboring states due to the Doppler broadening in a real atomic system.

•Jul 15, 2021•0 citations
We review our previous work on pump-probe spectroscopy in realistic degenerate two-level systems and model systems. In particular, we discuss the role of transfer of coherence (TOC) between the ground and excited hyperfine states in producing electromagnetically-induced transparency (EIA) peaks in the probe spectrum, when an Fg goes to Fe = Fg +1 transition in an alkali-metal atom interacts with a strong pump and weak probe that have perpendicular polarizations. When the pump is rho+ polarized and the probe pi polarized, this system can be modelled by an N system. We also discuss the role of transfer of population (TOP) between the Zeeman levels of the ground hyperfine state in producing EIA peaks when the pump and probe have the same polarization. This system can be modelled using a double two-level system. The role of Doppler broadening and phase-changing collisions in modifying the EIA-TOC and EIA-TOP absorption and refraction spectra is also discussed. All these spectra were calculated using MATLAB programs that both construct and solve the relevant Bloch equations. In our recent work, we consider the effect of a strong probe on the pump absorption and refraction spectra when the pump and probe polarizations are linear and perpendicular. It is difficult to solve this problem numerically due to the large number frequencies involved. In order to simplify the problem, we considered two cases: (i) rho+ polarized pump and pi polarized probe, and (ii) rho+ polarized pump and rho- polarized probe, and investigated a series of transitions in both Rb and Cs, using modified versions of the MATLAB programs devised for the weakprobe case. A number of interesting differences from the weak-probe case were found. For example, when the probe is sufficiently strong, we found the pump and probe spectra to show complementary behavior. In addition, as the number of Zeeman levels increase, the EIA peaks become progressively sharper, and are accompanied by steeper dispersion.
The absorption spectrum of a weak probe, interacting with a driven degenerate two-level atomic system, whose ground and excited hyperfine states are Fg,e,{\mathrm{F}}_{g,e},Fg,e​, can exhibit narrow peaks at line center. When the pump and probe polarizations are different, Fe=Fg+1{F}_{e}{=F}_{g}+1Fe​=Fg​+1 and Fg>0,{F}_{g}>0,Fg​>0, the electromagnetically induced absorption (EIA) peak has been shown to be due to the transfer of coherence (TOC) between the excited and ground states via spontaneous decay. We give a detailed explanation of why the TOC that leads to EIA (EIA-TOC) can only take place when ground-state population trapping does not occur, that is, when Fe=Fg+1.{F}_{e}{=F}_{g}+1.Fe​=Fg​+1. We also explain why EIA-TOC is observed in open systems. We show that EIA can also occur when the pump and probe polarizations are identical and Fe=Fg+1.{F}_{e}{=F}_{g}+1.Fe​=Fg​+1. This EIA is analogous to an effect that occurs in simple two-level systems when the collisional transfer of population (TOP) from the ground state to a reservoir is greater than that from the excited state. For a degenerate two-level system, the reservoir consists of the Zeeman sublevels of the ground hyperfine state, and of other nearby hyperfine states that do not interact with the pump. We will also discuss the four-wave mixing spectrum under the conditions where EIA-TOC and EIA-TOP occur.
We study the pump and probe absorption spectra, as a function of the probe detuning, in a degenerate two-level atomic system, for the case where the probe intensity is high enough to affect the pump absorption. The theory is valid for any ${F}_{g}\ensuremath{\rightarrow}{F}_{e}$ alkali-metal transition interacting with an arbitrarily intense pump and probe (with general Rabi frequencies ${\ensuremath{\Omega}}_{1,2}$) which are perpendicularly polarized with either ${\ensuremath{\sigma}}_{\ifmmode\pm\else\textpm\fi{}}$ or $\ensuremath{\pi}$ polarization. We have constructed a computer program that can calculate the spectra without requiring one to write out the Bloch equations explicitly. We show that, when the pump is ${\ensuremath{\sigma}}_{\ifmmode\pm\else\textpm\fi{}}$ polarized and the probe $\ensuremath{\pi}$ polarized, or vice versa, the pump and probe absorptions depend on the Zeeman coherences between the nearest-neighboring ground or excited Zeeman sublevels, whereas when the pump is ${\ensuremath{\sigma}}_{+}$ polarized and the probe ${\ensuremath{\sigma}}_{\ensuremath{-}}$ polarized, or vice versa, the Zeeman coherences that directly determine the absorption are between next-nearest neighbors. We report calculations of the pump and probe absorption spectra for the cycling ${F}_{g}=2\ensuremath{\rightarrow}{F}_{e}=3$ transition in the D2{D}_{2}D2​ line of 87Rb^{87}\text{R}\text{b}87Rb, interacting with a resonant ${\ensuremath{\sigma}}_{+}$-polarized pump and either a $\ensuremath{\pi}$- or a ${\ensuremath{\sigma}}_{\ensuremath{-}}$- polarized probe. The probe and pump absorption spectra are analyzed by considering the contributions that derive from the individual ${m}_{g}\ensuremath{\rightarrow}{m}_{e}$ transitions. We then show how these contributions depend on the ground- and excited-state populations and Zeeman coherences, and investigate the role played by transfer of coherence from the excited to the ground hyperfine state. We show that the pump and probe absorption spectra are mirror images of each other when ${\ensuremath{\Omega}}_{1}\ensuremath{\ge}{\ensuremath{\Omega}}_{2}>\ensuremath{\Gamma}$, and have the same behavior at line center and complementary behavior in the wings, when ${\ensuremath{\Omega}}_{1}\ensuremath{\ge}{\ensuremath{\Omega}}_{2}<\ensuremath{\Gamma}$ ($\ensuremath{\Gamma}$ is the rate of spontaneous decay from Fe{F}_{e}Fe​ to Fg{F}_{g}Fg​).
We predict the occurrence of electromagnetically induced absorption (EIA) in cycling degenerate two-level transitions where Fe=Fg+1{F}_{e}={F}_{g}+1Fe​=Fg​+1 and Fg>0{F}_{g}>0Fg​>0, interacting with pump and probe lasers with the same polarization. The EIA is due to transfer of population (TOP) between the Zeeman levels of the ground hyperfine state, rather than transfer of coherence (TOC) which occurs for perpendicularly polarized lasers. We model EIA-TOP using a double two-level system (TLS) which we compare with the four-level NNN system, which models EIA-TOC. When the pump intensity is low, both models give an EIA peak at line center. The effect of introducing phase-changing collisions is studied, in the presence and absence of Doppler broadening, for both the double TLS and NNN systems. In the presence of phase-changing collisions, the central EIA peaks are narrowed in both models and persist to higher pump Rabi frequencies than in the absence of collisions. In the double TLS, in the presence of Doppler broadening, the central EIA-TOP peak becomes narrower and does not develop a dip in its center, in contrast to the NNN system. The central dip that appears in the Doppler-broadened EIA-TOC spectrum can be wiped out by adding phase-changing collisions. We demonstrate that EIA-TOP can be obtained for realistic atomic transitions interacting with lasers that have the same polarization.
We investigate the atomic four-level NNN configuration both analytically and numerically, for various pump and probe intensities, with and without transfer of coherence (TOC) and Doppler broadening, and compare the results obtained to those of realistic atomic systems. We find that TOC affects the whole spectrum, in addition to producing an electromagnetically induced absorption (EIA) peak at line center. We show that the EIA peak splits as the pump intensity increases. These results are compared with those of realistic systems. When the pump is ${\ensuremath{\sigma}}^{+}$ polarized and the probe is $\ensuremath{\pi}$ polarized, the results are similar to those of the NNN configuration. When the pump and probe polarizations are both linear with perpendicular polarizations, various NNN-like subsystems contribute to the spectrum. Consequently, the splitting of the EIA peak only occurs at very high pump intensities. We also discuss the influence of the probe on the pump absorption and refraction and find that both the pump and probe show EIA peaks when the pump intensity is low, and complementary behavior when the pump is intense. At both low and high pump intensity, the pump and probe dispersions are of opposite sign.
In this paper, we present the theoretical study of double electromagnetically induced transparency (EIT) in a four-level V-type system which is formed by two co-propagating laser fields and the Zeeman sublevels of hyperfine transitions of 87Rb D2 line. The density matrix equations for the four-level V-type system are derived from the Liouville’s equation of motion and numerically solved under steady state condition to get the EIT signals. We consider both the probe and pump transmission spectra for the observation of double EIT signals under both Doppler free and Doppler broadened conditions. In case of Doppler free medium, two EIT peaks are formed in the two Lorentzian shape dips present in the both Doppler free probe and pump transmission spectra. When the medium becomes Doppler broadened, the two EIT peaks are formed in the probe transmission spectrum having Doppler broadened background, but the pump transmission spectrum gives two EIT peaks in the Doppler free background. The effect of probe intensity variation on the two EIT peaks is studied in case of Doppler broadened probe transmission spectrum. It is found that the heights of the EIT peaks decrease as the probe intensity increases, and interestingly one EIT peak converts into EIA (electromagnetically induced absorption) dip at some strong probe intensity value. The depth of the EIA dip is significantly increased as the intensity of the probe field increases. We also present the effect of probe intensity variation on the EIT peaks in the pump transmission spectrum and found that the EIT peak heights are increased as the probe intensity increases.
Abstract Optical Bloch equations with and without neighboring hyperfine states near the degenerate two-level system (DTLS) in the challenging case of 85Rb D2 transition that involves the Doppler broadening effect are solved herein. The calculated spectra agree well with the experimental results obtained using the coupling-probe scheme with orthogonal linear polarizations of the coupling and probe fields. The mechanisms of electromagnetically induced absorption (electromagnetically induced transparency) for the open Fg = 3 → Fe = 2 and 3 transitions (open Fg = 2 → Fe = 2 and 3 transitions) are clearly determined to be the effect of the strong closed Fg = 3 → Fe = 4 transition line (strong closed Fg = 2 → Fe = 1 transition line) based on the comparisons of the calculated absorption profiles of a DTLS without neighboring states and those of all levels with neighboring states depending on the coupling and probe power ratios. The crucial factors established based on comparisons of the calculated absorption profiles of DTLS with and without neighboring states, which enhance or reduce coherence effects and result in transformation between electromagnetically induced absorption and electromagnetically induced transparency, are the power ratios between coupling and probe beams, openness of the excited state, and effects of the neighboring states due to the Doppler broadening in a real atomic system.