Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optik

M-type atomic basic cell as a low intensity long wavelength infrared photodetector

M. Zyaei, Ali Rostami, H. Rasooli Saghai

Published Jul 14, 2011• 1 citation
Publisher
DOI
10.1016/j.ijleo.2011.04.012

Related papers

Long wavelength infrared photodetector design based on electromagnetically induced transparency

M. Zyaei, H. Rasooli Saghai, Karim Abbasian +1 more

Optics Communications•Apr 12, 2008•17 citations

Infrared imaging camera based on a Rydberg atom photodetector

Marcel Drabbels, Lambertus D. Noordam

A type of infrared imaging camera is demonstrated that uses gas-phase Rydberg atoms as photocathodes. The camera operates throughout the infrared part of the electromagnetic spectrum: λ=1–100 μm. The first results are presented and the potential of the camera as an ultrafast detector and a wavelength selective detector is discussed.

Applied Physics Letters•Mar 29, 1999•18 citations

Photodetection of non-classical light

B. Hüttner, Y. Ben-Aryeh

Optics Communications•Dec 1, 1988•6 citations

Near-single-photon atto-watt detection at mid-infrared wavelengths by a room-temperature balanced heterodyne set-up

Danièle Palaferri, Lorenzo Mancini, Chiara Vecchi +8 more

Abstract Single photon detection is the underpinning technology for quantum communication and quantum sensing applications. At visible and near-infrared wavelengths, single-photon-detectors (SPDs) underwent a significant development in the past two decades, with the commercialization of SPADs and superconducting detectors. At longer wavelengths, in the mid-infrared range (4-11µm), given the reduced scattering and favourable transparent atmospheric windows, there is an interest in developing quantum earth-satellites-links and quantum imaging for noisy environments or large-distance telescopes. Still, SPD-level mid-infrared devices have been rarely reported in the state-of-the-art (superconductors, single-electron-transistors or avalanche-photodiodes) and, crucially, all operating at cryogenic temperatures. Here, we demonstrate a room-temperature detection system operating at 4.6µm-wavelength with a sensitivity-level of atto-watt optical power, corresponding to few tens of mid-infrared photons. This result was obtained by exploiting a pair of commercially available photodetectors within two balanced-heterodyne-detection setups: one involving a quantum-cascade-laser (QCL) and an acousto-optic-modulator (AOM) and the other one including two QCLs with mutual coherence ensured by a phase-lock-loop (PLL). Our work not only validates a viable method to detect ultra-low-intensity signals, but is also potentially scalable to the entire wavelength range already accessible by mature QCL technology, unfolding - for the first time - quantum applications at mid- and long-wave-infrared-radiation.

arXiv:2412.09462•Feb 5, 2025•1 citation

Electromagnetically induced transparency based quantum well infrared photodetectors

Rohit Mukherjee, Swapan Konar

Journal of Luminescence•Aug 10, 2022•5 citations

Collapse and revival of a Dicke-type coherent narrowing in potassium vapor confined in a nanometric thin cell

Armen D. Sargsyan, Y. Pashayan-Leroy, Claude Leroy +1 more

Abstract A nanometer-thin cell (in the direction of laser beam propagation) has been elaborated with the thickness of the atomic vapor column varying smoothly in the range of . The cell allows one to study the behavior of the resonance absorption over the D 1 line of potassium atoms by varying the laser intensity and the cell thickness (from to with the step where is the resonant wavelength of the laser). It is shown that despite the huge Doppler broadening ( at the cell temperature ), at low laser intensities a narrowing of the resonance absorption spectrum is observed for ( at FWHM) and , whereas for and the spectrum broadens. At moderate laser intensities narrowband velocity selective optical pumping (VSOP) resonances appear at and with the linewidth close to the natural one. A comparison with saturated absorption spectra obtained in a 1.4 cm-sized K cell is presented. The developed theoretical model well describes the experiment.

arXiv:1511.03836•Journal of Physics B Atomic Molecular and Optical Physics•Mar 17, 2016•22 citations
Abstract Single photon detection is the underpinning technology for quantum communication and quantum sensing applications. At visible and near-infrared wavelengths, single-photon-detectors (SPDs) underwent a significant development in the past two decades, with the commercialization of SPADs and superconducting detectors. At longer wavelengths, in the mid-infrared range (4-11µm), given the reduced scattering and favourable transparent atmospheric windows, there is an interest in developing quantum earth-satellites-links and quantum imaging for noisy environments or large-distance telescopes. Still, SPD-level mid-infrared devices have been rarely reported in the state-of-the-art (superconductors, single-electron-transistors or avalanche-photodiodes) and, crucially, all operating at cryogenic temperatures. Here, we demonstrate a room-temperature detection system operating at 4.6µm-wavelength with a sensitivity-level of atto-watt optical power, corresponding to few tens of mid-infrared photons. This result was obtained by exploiting a pair of commercially available photodetectors within two balanced-heterodyne-detection setups: one involving a quantum-cascade-laser (QCL) and an acousto-optic-modulator (AOM) and the other one including two QCLs with mutual coherence ensured by a phase-lock-loop (PLL). Our work not only validates a viable method to detect ultra-low-intensity signals, but is also potentially scalable to the entire wavelength range already accessible by mature QCL technology, unfolding - for the first time - quantum applications at mid- and long-wave-infrared-radiation.
Abstract A nanometer-thin cell (in the direction of laser beam propagation) has been elaborated with the thickness of the atomic vapor column varying smoothly in the range of . The cell allows one to study the behavior of the resonance absorption over the D 1 line of potassium atoms by varying the laser intensity and the cell thickness (from to with the step where is the resonant wavelength of the laser). It is shown that despite the huge Doppler broadening ( at the cell temperature ), at low laser intensities a narrowing of the resonance absorption spectrum is observed for ( at FWHM) and , whereas for and the spectrum broadens. At moderate laser intensities narrowband velocity selective optical pumping (VSOP) resonances appear at and with the linewidth close to the natural one. A comparison with saturated absorption spectra obtained in a 1.4 cm-sized K cell is presented. The developed theoretical model well describes the experiment.