Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physica Scripta

Is the key of the ghost imaging mystery given by the electromagnetic crossing symmetric photon reactions?

L. Rusu, Al. Rusu

Published Mar 1, 2013• 0 citations
Publisher

Abstract

In the ghost imaging system, the object and image are separately illuminated by a pair of correlated beams and the image is obtained through coincidence detection of the two beams. When the correlated beams are obtained by a spontaneous parametric down-conversion phenomenon, the image formation is attributed to either quantum entanglement or wave vector correlation. The physicist D B Ion has published a different point of view: the ghost imaging can be explained by electromagnetic crossing symmetric photon reactions. We report on an experimental setup to verify that a change of the object reflection coefficient modifies the idler single count rate. The obtained results are a confirmation proof and suggest the existence of a stimulated spontaneous parametric down-conversion effect. A possible application is mentioned.

DOI
10.1088/0031-8949/2013/t153/014054

Related papers

A stimulated spontaneous down conversion effect

Al. Rusu, L. Rusu

A ghost imaging setup having a spontaneous down conversion (SPDC) entangled photon source is considered. The experimental results prove that a change of the object reflection coefficient modifies the idler single count rate. An infrared laser acting as “signal reflected photons” source intensifies the idler single count rate. A crude explanation of this effect could be the stimulated SPDC photon pair generation. Fascinating applications arise: stimulated high intensity SPDC entangled photon sources.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jun 10, 2013•0 citations

Two-Photon Ghost Image and Interference-Diffraction

Yanhua H. Shih, Alexander V. Sergienko, T. B. Pittman +2 more

One of the most surprising consequences of quantum mechanics is entanglement of two or more distance particles. The two-particle entangled state was mathematically formulated by Schrodinger. Based on this unusual quantum behavior, EPR defined their 'physical reality' and then asked the question: 'Can Quantum-Mechanical Description of Physical Reality Be Considered Complete?' One may not appreciate EPR's criterion of physical reality and insist that 'no elementary quantum phenomenon is a phenomenon until it is a recorded phenomenon'. Optical spontaneous parametric down conversion (SPDC) is the most effective mechanism to generate an EPR type entangled two-photon state. In SPDC, an optical beam, called the pump, is incident on a birefringent crystal. The pump is intense enough so that nonlinear effects lead to the conversion of pump photons into pairs of photons, historically called signal and idler. Technically, the SPDC is said to be type-1 or type-2, depending on whether the signal and idler beams have parallel or orthogonal polarization. The SPDC conversion efficiency is typically on the order of 10(exp -9) to 10(exp -11), depending on the SPDC nonlinear material. The signal and idler intensities are extremely low, only single photon detection devices can register them. The quantum entanglement nature of SPDC has been demonstrated in EPR-Bohm experiments and Bell's inequality measurements. The following two experiments were recently performed in our laboratory, which are more closely related to the original 1935 EPR gedankenezperiment. The first experiment is a two-photon optical imaging type experiment, which has been named 'ghost image' by the physics community. The signal and idler beams of SPDC are sent in different directions, so that the detection of the signal and idler photons can be performed by two distant photon counting detectors. An aperture object (mask) is placed in front of the signal photon detector and illuminated by the signal beam through a convex lens. Surprisingly, an image of this aperture is observed in the idler beam, by scanning the idler photon detector in the transverse plane of the idler beam, if we are sure that the idler photon detector 'catches' the 'twin brother' of the signal, which can be easily performed by a coincidence measurement. This effect is even more striking when we found that the object-lens-image relationship satisfies the Gaussian thin lens equation. The second experiment demonstrates two-photon 'ghost' interference-diffraction. The experimental set up is similar to the image experiment, except that rather than a lens and an aperture it is a Young's double-slit (or a single-slit) inserted into the path of the signal beam. We could not find any interference (or diffraction) pattern behind the slit. Surprisingly, an interference (or diffraction) pattern is observed when scanning the detector in the idler beam, if we are sure that the idler photon detector 'catches' the 'twin brother' of the signal.

•Jan 1, 1996•0 citations

Accessible “Spooky Action at a Distance”

Tate Thomas, Dulcinea Cabreda

“Ghost” imaging is a process utilizing entangled photon pairs, by which an image is produced indirectly, using photons that have never interacted with the object being imaged. We can do this by taking advantage of correlations inherent in Spontaneous Parametric Down Conversion (SPDC), which is used to produce these entangled photon pairs. SPDC is a classically forbidden process in which a photon of a high frequency is converted into a pair of photons. The change in frequency makes this a nonlinear process. Processes like absorption, reflection, refraction, and polarization are linear processes. These can affect the properties of a light field but cannot change the frequency. SPDC allows us to produce a pair of correlated photons. By utilizing a coincidence-counter, we will be able to measure photon pairs from the source beam arriving within a narrow time interval. With this restriction, we can limit our attention to these correlated photons. One of these photons, which does interact with the object to be imaged, is used to turn on a “camera” detecting the other photon. It is the correlations between these photons that allow for ghost imaging, the reconstruction of the image of an object, even though the object never interacts directly with those single photons that are going to our camera.

•Apr 11, 2026•0 citations

Quantum Ghost Image Identification with Correlated Photon Pairs

Mehul Malik, Heedeuk Shin, Malcolm N. O’Sullivan +2 more

Ghost imaging can be performed using either quantum or classical states of light that possess strong spatial correlations. In both cases, the image is formed by averaging over many optical events. Here we show that it is possible to distinguish an object from a preestablished basis set of objects by using a small number of position-correlated photon pairs produced by spontaneous parametric down-conversion. The signal photon is incident on one member of a set of spatially nonoverlapping objects. The "ghost" image information is impressed upon the spatially separated idler photon and is extracted by means of holographic filtering and coincidence detection. We were able to distinguish among sets of two and four spatially nonoverlapping objects with confidence levels higher than 87% and 81%, respectively. This method of ghost imaging can be performed in situations requiring extremely low light levels.

Physical Review Letters•Apr 23, 2010•47 citations

Robust Ghost Imaging Based on Degenerate Spontaneous Parametric Down-Conversion

Ling‐Jun Kong, Yu Si, Rui Liu +5 more

In traditional ghost imaging, the entangled photon pairs produced from the spontaneous parametric down conversion (SPDC) process are used. There is an intrinsic disadvantage that the utilization efficiency of the photon pairs is very low. Inasmuch as all the correlated photon pairs produced by the degenerate SPDC process can be used to record the image of an object, the ghost imaging scheme we present here has a higher utilization efficiency of the photon pairs. We also investigate the robustness of our experimental scheme. The experimental results show that, no matter whether the photon-pair source is two light cones or two beam-like spots, the clear image of the object can be obtained. The slight rotation of the nonlinear crystal has no influence on the imaging quality. Our experimental results also demonstrate that when the part of the photon-pair source in the signal path or the idler path is blocked by unwanted things, the clear ghost image of the object can still be recorded.

Chinese Physics Letters•May 1, 2017•0 citations

Applications of Quantum Entanglement Towards “Ghost” Imaging

Weronika Pach

In this work, pairs of entangled photons are aimed at two spatially separated detectors: the path to one detector contains a physical object, while the path to the second detector does not. Yet, the second detector can be used to create an image of the object, even though none of the photons arriving at that detector have ever interacted with the object! This “ghost” imaging takes advantage of information that is shared between entangled photon pairs. This work aims to explore the underlying principles in a ghost imaging system that utilizes spontaneous parametric down-conversion (SPDC) as the source of entangled photons, with the larger goal of understanding the principles and operation of key parts of the system.

•Jan 1, 2018•0 citations
In the ghost imaging system, the object and image are separately illuminated by a pair of correlated beams and the image is obtained through coincidence detection of the two beams. When the correlated beams are obtained by a spontaneous parametric down-conversion phenomenon, the image formation is attributed to either quantum entanglement or wave vector correlation. The physicist D B Ion has published a different point of view: the ghost imaging can be explained by electromagnetic crossing symmetric photon reactions. We report on an experimental setup to verify that a change of the object reflection coefficient modifies the idler single count rate. The obtained results are a confirmation proof and suggest the existence of a stimulated spontaneous parametric down-conversion effect. A possible application is mentioned.
A ghost imaging setup having a spontaneous down conversion (SPDC) entangled photon source is considered. The experimental results prove that a change of the object reflection coefficient modifies the idler single count rate. An infrared laser acting as “signal reflected photons” source intensifies the idler single count rate. A crude explanation of this effect could be the stimulated SPDC photon pair generation. Fascinating applications arise: stimulated high intensity SPDC entangled photon sources.
One of the most surprising consequences of quantum mechanics is entanglement of two or more distance particles. The two-particle entangled state was mathematically formulated by Schrodinger. Based on this unusual quantum behavior, EPR defined their 'physical reality' and then asked the question: 'Can Quantum-Mechanical Description of Physical Reality Be Considered Complete?' One may not appreciate EPR's criterion of physical reality and insist that 'no elementary quantum phenomenon is a phenomenon until it is a recorded phenomenon'. Optical spontaneous parametric down conversion (SPDC) is the most effective mechanism to generate an EPR type entangled two-photon state. In SPDC, an optical beam, called the pump, is incident on a birefringent crystal. The pump is intense enough so that nonlinear effects lead to the conversion of pump photons into pairs of photons, historically called signal and idler. Technically, the SPDC is said to be type-1 or type-2, depending on whether the signal and idler beams have parallel or orthogonal polarization. The SPDC conversion efficiency is typically on the order of 10(exp -9) to 10(exp -11), depending on the SPDC nonlinear material. The signal and idler intensities are extremely low, only single photon detection devices can register them. The quantum entanglement nature of SPDC has been demonstrated in EPR-Bohm experiments and Bell's inequality measurements. The following two experiments were recently performed in our laboratory, which are more closely related to the original 1935 EPR gedankenezperiment. The first experiment is a two-photon optical imaging type experiment, which has been named 'ghost image' by the physics community. The signal and idler beams of SPDC are sent in different directions, so that the detection of the signal and idler photons can be performed by two distant photon counting detectors. An aperture object (mask) is placed in front of the signal photon detector and illuminated by the signal beam through a convex lens. Surprisingly, an image of this aperture is observed in the idler beam, by scanning the idler photon detector in the transverse plane of the idler beam, if we are sure that the idler photon detector 'catches' the 'twin brother' of the signal, which can be easily performed by a coincidence measurement. This effect is even more striking when we found that the object-lens-image relationship satisfies the Gaussian thin lens equation. The second experiment demonstrates two-photon 'ghost' interference-diffraction. The experimental set up is similar to the image experiment, except that rather than a lens and an aperture it is a Young's double-slit (or a single-slit) inserted into the path of the signal beam. We could not find any interference (or diffraction) pattern behind the slit. Surprisingly, an interference (or diffraction) pattern is observed when scanning the detector in the idler beam, if we are sure that the idler photon detector 'catches' the 'twin brother' of the signal.
“Ghost” imaging is a process utilizing entangled photon pairs, by which an image is produced indirectly, using photons that have never interacted with the object being imaged. We can do this by taking advantage of correlations inherent in Spontaneous Parametric Down Conversion (SPDC), which is used to produce these entangled photon pairs. SPDC is a classically forbidden process in which a photon of a high frequency is converted into a pair of photons. The change in frequency makes this a nonlinear process. Processes like absorption, reflection, refraction, and polarization are linear processes. These can affect the properties of a light field but cannot change the frequency. SPDC allows us to produce a pair of correlated photons. By utilizing a coincidence-counter, we will be able to measure photon pairs from the source beam arriving within a narrow time interval. With this restriction, we can limit our attention to these correlated photons. One of these photons, which does interact with the object to be imaged, is used to turn on a “camera” detecting the other photon. It is the correlations between these photons that allow for ghost imaging, the reconstruction of the image of an object, even though the object never interacts directly with those single photons that are going to our camera.
Ghost imaging can be performed using either quantum or classical states of light that possess strong spatial correlations. In both cases, the image is formed by averaging over many optical events. Here we show that it is possible to distinguish an object from a preestablished basis set of objects by using a small number of position-correlated photon pairs produced by spontaneous parametric down-conversion. The signal photon is incident on one member of a set of spatially nonoverlapping objects. The "ghost" image information is impressed upon the spatially separated idler photon and is extracted by means of holographic filtering and coincidence detection. We were able to distinguish among sets of two and four spatially nonoverlapping objects with confidence levels higher than 87% and 81%, respectively. This method of ghost imaging can be performed in situations requiring extremely low light levels.
In traditional ghost imaging, the entangled photon pairs produced from the spontaneous parametric down conversion (SPDC) process are used. There is an intrinsic disadvantage that the utilization efficiency of the photon pairs is very low. Inasmuch as all the correlated photon pairs produced by the degenerate SPDC process can be used to record the image of an object, the ghost imaging scheme we present here has a higher utilization efficiency of the photon pairs. We also investigate the robustness of our experimental scheme. The experimental results show that, no matter whether the photon-pair source is two light cones or two beam-like spots, the clear image of the object can be obtained. The slight rotation of the nonlinear crystal has no influence on the imaging quality. Our experimental results also demonstrate that when the part of the photon-pair source in the signal path or the idler path is blocked by unwanted things, the clear ghost image of the object can still be recorded.
In this work, pairs of entangled photons are aimed at two spatially separated detectors: the path to one detector contains a physical object, while the path to the second detector does not. Yet, the second detector can be used to create an image of the object, even though none of the photons arriving at that detector have ever interacted with the object! This “ghost” imaging takes advantage of information that is shared between entangled photon pairs. This work aims to explore the underlying principles in a ghost imaging system that utilizes spontaneous parametric down-conversion (SPDC) as the source of entangled photons, with the larger goal of understanding the principles and operation of key parts of the system.