Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physica Scripta

Trapped Ion Optical Frequency Standards

Patrick Robert Gill, G. P. Barwood, Guozheng Huang, Hugh A. Klein, Peter Blythe, Kazumoto Hosaka, Richard Claude Thompson, Stephen A. Webster, S.N. Lea, Helen S. Margolis

Published Jan 1, 2004• 14 citations
Publisher

Abstract

Weak transitions in single cold trapped ions are highly reproducible as optical frequency standards on account of the high quality factors and stabilities achievable. In recent years, there has been a quickening pace in the development of these optical frequency standards, particularly due to the emergence of femtosecond laser combs for relating the optical frequency directly to the Cs standard. This paper reports progress on optical frequency standards based on the quadrupole transition in a single cold ion of 88 Sr + and the octupole transition in a single cold ion of 171 Yb + .

DOI
10.1238/physica.topical.112a00063

Related papers

Trapped ion optical frequency standards

Patrick Robert Gill, G. P. Barwood, Hugh A. Klein +6 more

Optical frequency standards based on narrow absorptions in laser-cooled single trapped ions have recently begun to demonstrate stabilities that are competitive with cold atom fountain microwave standards. This paper presents a short review of the wider state-of-the-art development of these single cold trapped ion frequency standards, coupled with a more detailed account of recent results achieved at National Physical Laboratory in respect of single ion systems based on 88Sr+, 87Sr+ and 171Yb+. Narrow linewidth data for the optical clock quadrupole and octupole transitions respectively at 674 nm in 88Sr+ and 467 nm in 171Yb+, are presented, together with a discussion of current systematics and future projections. The potential for optical clock operation is outlined.

Measurement Science and Technology•Jul 16, 2003•44 citations

Optical frequency standard based on a trapped171Yb+ion

Chr. Tamm, T. Schneider, E. Peik

We describe experimental investigations on an optical frequency standard based on a single laser cooled 171Yb+ ion confined in a radiofrequency Paul trap. The 435.5 nm electric-quadrupole transition from the 2S1/2(F=0) groudn state to the 2D3/2(F=2) state is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Foruier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency is determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 321 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1×10-14.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 8, 2003•0 citations

Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion

Helen S. Margolis, G. P. Barwood, Guozheng Huang +4 more

The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.

Science•Nov 18, 2004•302 citations

Optical frequency standards and clocks based on single trapped ions

Helen S. Margolis, G. P. Barwood, Kazumoto Hosaka +6 more

Forbidden transitions in single laser-cooled trapped ions provide highly stable and accurate references for optical frequency standards. This paper describes recent progress on strontium and ytterbium ion optical frequency standards under development at NPL.

Conference on Lasers and Electro-Optics•Jan 1, 2006•0 citations

Progress toward a single ytterbium ion optical clock

Paul Taylor, Stephen A. Webster, Matthew Roberts +3 more

Forbidden transitions in single trapped ion systems are being considered as references for future optical frequency standards. These standards are expected to have application as highly stable and reproducible optical clocks, realizations of the metre and as optical frequency standards in their own right. This paper prescribes the work carried out at the National Physical Laboratory over recent years to use a highly forbidden 2S1/2 - 2F7/2 467 nm electric octupole transition in a single ion of 171Yb+ as a frequency reference. A review of the previous measurements needed to the locate octupole transition in this 171-isotope is given and a more detailed discussion of recent work is presented. This includes spectroscopy of the octupole transition with kilohertz resolution and a direct measurement of its optical frequency. Measurements of the dynamic Stark and the quadratic Zeeman shifts on the octupole frequency are also discussed.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 3, 2001•0 citations

High-resolution spectroscopy of the88Sr+single ion optical frequency standard

P. Dubé, Alan A. Madej, J. E. Bernard +1 more

The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 29, 2007•8 citations
Weak transitions in single cold trapped ions are highly reproducible as optical frequency standards on account of the high quality factors and stabilities achievable. In recent years, there has been a quickening pace in the development of these optical frequency standards, particularly due to the emergence of femtosecond laser combs for relating the optical frequency directly to the Cs standard. This paper reports progress on optical frequency standards based on the quadrupole transition in a single cold ion of 88 Sr + and the octupole transition in a single cold ion of 171 Yb + .
Optical frequency standards based on narrow absorptions in laser-cooled single trapped ions have recently begun to demonstrate stabilities that are competitive with cold atom fountain microwave standards. This paper presents a short review of the wider state-of-the-art development of these single cold trapped ion frequency standards, coupled with a more detailed account of recent results achieved at National Physical Laboratory in respect of single ion systems based on 88Sr+, 87Sr+ and 171Yb+. Narrow linewidth data for the optical clock quadrupole and octupole transitions respectively at 674 nm in 88Sr+ and 467 nm in 171Yb+, are presented, together with a discussion of current systematics and future projections. The potential for optical clock operation is outlined.
We describe experimental investigations on an optical frequency standard based on a single laser cooled 171Yb+ ion confined in a radiofrequency Paul trap. The 435.5 nm electric-quadrupole transition from the 2S1/2(F=0) groudn state to the 2D3/2(F=2) state is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Foruier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency is determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 321 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1×10-14.
The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.
Forbidden transitions in single trapped ion systems are being considered as references for future optical frequency standards. These standards are expected to have application as highly stable and reproducible optical clocks, realizations of the metre and as optical frequency standards in their own right. This paper prescribes the work carried out at the National Physical Laboratory over recent years to use a highly forbidden 2S1/2 - 2F7/2 467 nm electric octupole transition in a single ion of 171Yb+ as a frequency reference. A review of the previous measurements needed to the locate octupole transition in this 171-isotope is given and a more detailed discussion of recent work is presented. This includes spectroscopy of the octupole transition with kilohertz resolution and a direct measurement of its optical frequency. Measurements of the dynamic Stark and the quadratic Zeeman shifts on the octupole frequency are also discussed.
The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.