Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Nature Photonics

Optical lattice clocks and quantum metrology

Hidetoshi Katori

Published Mar 31, 2011• 282 citations
Publisher
DOI
10.1038/nphoton.2011.45

Related papers

Optical lattice clocks : Metrology and quantum technologies

Jérôme Lodewyck

•Nov 1, 2019•0 citations

Optical Lattice Clocks for Precision Time and Frequency Metrology

Masao Takamoto, Hidetoshi Katori

Lecture notes in physics•Dec 29, 2015•3 citations

Sr optical lattice clocks at LNE SYRTE: metrology, quantum technologies, and fundamental physics

Grégoire Vallet, B. X. R. Alves, Yannick Foucault +2 more

•Jan 1, 2018•0 citations

Quantum enhanced metrology in the optical lattice clock

Chi Shu

High-bandwidth, high-stability clocks offer unique chances to study fundamental physics beyond simple metrology. Today, the most stable clocks are optical lattice clocks and they can reach a fractional stability of 3.1 × 10^−18 at 1 s averaging time. Their applications are ranging from the redefinition of the SI time unit, the Second, to the possible detection of gravitational waves in space. The stability of optical lattice clocks is primarily limited by quantum projection noise and Dick noise. In this thesis, I present our effort in creating a platform for studying quantum enhanced metrology and its application towards optical lattice clocks. We demonstrated the laser cooling in an optical cavity with Raman-sideband cooling and achieved average vibration number of n = 0.2. We utilized cavity feedback squeezing to demonstrate unitary spin squeezing on magnetic sub-levels of 171Yb, achieving 6.5 dB quantum projection noise reduction over the standard quantum limit (SQL). With coherent optical state transfer by ultra stable laser pulses, we successfully transferred the spin squeezed state from magnetic sub-levels to the optical transition, and demonstrated quantum enhanced metrology in the optical lattice clock for the first time. We achieved 4.4 dB of metrological gain over the SQL, which corresponds to a reduction of the averaging time by a factor of 2.8 in clock operation. Furthermore, we studied quantum enhanced metrology with time-reversal-based protocols. We performed a signal amplification through time-reversed interaction protocol between the ground state magnetic sublevels of 171Yb, achieving the largest sensitivity improvement beyond SQL in any interferometers to date at 11.8dB. Besides that, we experimentally studied the connection between quantum information scrambling, by measuring out-of-time-order correlators (OTOCs), and quantum metrology, by measuring metrological gain. We found these values to agree with each other, and concluded that the time-reversal quantum metrology can saturate the attainable gain from the quantum information scrambling.

•Jan 1, 2023•0 citations

Floquet Engineering Hz-Level Rabi Spectra in Shallow Optical Lattice Clock

Mo-Juan Yin, Xiaotong Lu, Ting Li +4 more

Quantum metrology with ultrahigh precision usually requires atoms prepared in an ultrastable environment with well-defined quantum states. Thus, in optical lattice clock systems deep lattice potentials are used to trap ultracold atoms. However, decoherence, induced by Raman scattering and higher order light shifts, can significantly be reduced if atomic clocks are realized in shallow optical lattices. On the other hand, in such lattices, tunneling among different sites can cause additional dephasing and strongly broadening of the Rabi spectrum. Here, in our experiment, we periodically drive a shallow ^{87}Sr optical lattice clock. Counterintuitively, shaking the system can deform the wide broad spectral line into a sharp peak with 5.4 Hz linewidth. With careful comparison between the theory and experiment, we demonstrate that the Rabi frequency and the Bloch bands can be tuned, simultaneously and independently. Our work not only provides a different idea for quantum metrology, such as building shallow optical lattice clock in outer space, but also paves the way for quantum simulation of new phases of matter by engineering exotic spin orbit couplings.

arXiv:2110.07169•Physical Review Letters•Feb 17, 2022•35 citations

Optical lattice clocks

P. Lemonde

The European Physical Journal Special Topics•Jun 1, 2009•34 citations
High-bandwidth, high-stability clocks offer unique chances to study fundamental physics beyond simple metrology. Today, the most stable clocks are optical lattice clocks and they can reach a fractional stability of 3.1 × 10^−18 at 1 s averaging time. Their applications are ranging from the redefinition of the SI time unit, the Second, to the possible detection of gravitational waves in space. The stability of optical lattice clocks is primarily limited by quantum projection noise and Dick noise. In this thesis, I present our effort in creating a platform for studying quantum enhanced metrology and its application towards optical lattice clocks. We demonstrated the laser cooling in an optical cavity with Raman-sideband cooling and achieved average vibration number of n = 0.2. We utilized cavity feedback squeezing to demonstrate unitary spin squeezing on magnetic sub-levels of 171Yb, achieving 6.5 dB quantum projection noise reduction over the standard quantum limit (SQL). With coherent optical state transfer by ultra stable laser pulses, we successfully transferred the spin squeezed state from magnetic sub-levels to the optical transition, and demonstrated quantum enhanced metrology in the optical lattice clock for the first time. We achieved 4.4 dB of metrological gain over the SQL, which corresponds to a reduction of the averaging time by a factor of 2.8 in clock operation. Furthermore, we studied quantum enhanced metrology with time-reversal-based protocols. We performed a signal amplification through time-reversed interaction protocol between the ground state magnetic sublevels of 171Yb, achieving the largest sensitivity improvement beyond SQL in any interferometers to date at 11.8dB. Besides that, we experimentally studied the connection between quantum information scrambling, by measuring out-of-time-order correlators (OTOCs), and quantum metrology, by measuring metrological gain. We found these values to agree with each other, and concluded that the time-reversal quantum metrology can saturate the attainable gain from the quantum information scrambling.
Quantum metrology with ultrahigh precision usually requires atoms prepared in an ultrastable environment with well-defined quantum states. Thus, in optical lattice clock systems deep lattice potentials are used to trap ultracold atoms. However, decoherence, induced by Raman scattering and higher order light shifts, can significantly be reduced if atomic clocks are realized in shallow optical lattices. On the other hand, in such lattices, tunneling among different sites can cause additional dephasing and strongly broadening of the Rabi spectrum. Here, in our experiment, we periodically drive a shallow ^{87}Sr optical lattice clock. Counterintuitively, shaking the system can deform the wide broad spectral line into a sharp peak with 5.4 Hz linewidth. With careful comparison between the theory and experiment, we demonstrate that the Rabi frequency and the Bloch bands can be tuned, simultaneously and independently. Our work not only provides a different idea for quantum metrology, such as building shallow optical lattice clock in outer space, but also paves the way for quantum simulation of new phases of matter by engineering exotic spin orbit couplings.