Physics Letters

Frequency shifts of optical double resonance signals by multiple coherent scattering

Ernst Wilhelm Otten, Albrecht Winnacker

Published Nov 1, 1966• 1 citation
Publisher
DOI
10.1016/0031-9163(66)91096-1

Related papers

Optical double resonance experiments

Alan Corney

Oxford University Press eBooks•Oct 5, 2006•0 citations

Intensity nonlinearity of the error-signal frequency shift in the modulation spectroscopy of dark resonances and approaches to its reduction

Eugene A. Tsygankov, Sergey Petropavlovsky, Maria I. Vaskovskaya +5 more

We have found that the error-signal frequency corresponding to the coherent population trapping resonance can be displaced from that of "$0-0$" transition unperturbed by the optical field, although the frequency is not sensitive to changes in its intensity. We consider the double $Λ$-system of levels interacting with the asymmetric polychromatic optical field to demonstrate that this effect arises due to intensity nonlinearity of the error-signal frequency shift. The experiment with $^{87}$Rb atoms in Ar-N$_2$ buffer gas atomic cell shows how the displacement value depends on different parameters. The possible influence of the effect on the clocks' frequency stability and reproducibility are discussed.

arXiv:2012.13731•Dec 26, 2020•1 citation

Frequency non-mutuality of collision-induced four-wave mixing signal

S. Ya. Kilin, A F Fedorov

It is shown that the collision-induced four-wave mixing signal in two-photon quasi-resonant excitation has the property of frequency non-mutuality, i.e. when the probe field frequency omega s is replaced by the signal frequency omega out the four-wave mixing coherent signal does not arise. The reason for such frequency non-mutuality lies in the nature of the collision-induced coherent scattering. It is shown that this scattering occurs because of double non-adiabatic transitions (as affected by collisions) between the states of a dressed atom without changing the environment (buffer) state during the four-photon-scattering elementary process; this scattering will be referred to as coherent collisionally double induced scattering (CCDIS).

Journal of Physics B Atomic and Molecular Physics•Sep 14, 1986•2 citations

Cooperative effects in optical double resonance

G. S. Agarwal, P. Anantha Lakshmi

Optics Communications•Dec 1, 1980•5 citations

Optical double resonance spectra under finite bandwidth excitations

Richard D’Souza, Q. V. Lawande, S. V. Lawande

Optics Communications•Jul 1, 1984•10 citations

Laser pumped 4He magnetometer with light shift suppression

Zaisheng Lin, He Wang, Xiang Peng +2 more

We report a laser-pumped 4He atomic magnetometer with light shift suppression through the atomic sensor itself. A linearly polarized light is used to optically align the 4He metastable atoms and we monitor the magneto-optical double resonance (MODR) signals produced by the left- and right-circularly orthogonal components. It is shown that light shift leads to the atomic alignment to orientation conversion effect, and thus, the difference between the two MODR signals. One of these two MODR signals is locked at the Larmor frequency and is used to measure the ambient magnetic field, while the differential signal is, simultaneously, fed back to suppress the light shift. The scheme could be of the advantage to the design of compact magnetometers by reducing the systematic errors due to light shift.

Review of Scientific Instruments•Nov 1, 2016•6 citations
We have found that the error-signal frequency corresponding to the coherent population trapping resonance can be displaced from that of "0−00-00−0" transition unperturbed by the optical field, although the frequency is not sensitive to changes in its intensity. We consider the double ΛΛΛ-system of levels interacting with the asymmetric polychromatic optical field to demonstrate that this effect arises due to intensity nonlinearity of the error-signal frequency shift. The experiment with 87^{87}87Rb atoms in Ar-N2_22​ buffer gas atomic cell shows how the displacement value depends on different parameters. The possible influence of the effect on the clocks' frequency stability and reproducibility are discussed.
It is shown that the collision-induced four-wave mixing signal in two-photon quasi-resonant excitation has the property of frequency non-mutuality, i.e. when the probe field frequency omega s is replaced by the signal frequency omega out the four-wave mixing coherent signal does not arise. The reason for such frequency non-mutuality lies in the nature of the collision-induced coherent scattering. It is shown that this scattering occurs because of double non-adiabatic transitions (as affected by collisions) between the states of a dressed atom without changing the environment (buffer) state during the four-photon-scattering elementary process; this scattering will be referred to as coherent collisionally double induced scattering (CCDIS).
We report a laser-pumped 4He atomic magnetometer with light shift suppression through the atomic sensor itself. A linearly polarized light is used to optically align the 4He metastable atoms and we monitor the magneto-optical double resonance (MODR) signals produced by the left- and right-circularly orthogonal components. It is shown that light shift leads to the atomic alignment to orientation conversion effect, and thus, the difference between the two MODR signals. One of these two MODR signals is locked at the Larmor frequency and is used to measure the ambient magnetic field, while the differential signal is, simultaneously, fed back to suppress the light shift. The scheme could be of the advantage to the design of compact magnetometers by reducing the systematic errors due to light shift.