Japanese Journal of Applied Physics

Enhancement of Flux Sensitivity by Parallel Operation of rf SQUID

Hisao Furukawa, K. Shirae, Kozo Kishida

Published Jul 1, 1981• 0 citations
Publisher

Abstract

A new configuration, parallel operation of a number of rf SQUID elements provides enhanced sensitivity. This parallel operated elements has been fabricated by Nb thin film on single substrate, and drived by a single tank circuit. The variations of step pattern, interference pattern and flux sensitivity by increasing the number of elements have been measured. By performing parallel operation of four rf SQUID elements, the amplitude of interference pattern is increased two times as large as for single element case, and this agree well with theoretical analysis. Consequently, flux sensitivity is also enhanced similarly.

DOI
10.1143/jjap.20.l526

Related papers

Low-noise YBa2Cu3O7 rf SQUID magnetometer

Yi Zhang, H.-M. Mück, Klaus Dieter Herrmann +4 more

A superconducting quantum interferometer device (SQUID) electronics with tank frequencies near 150 MHz was constructed to enhance the rf SQUID sensitivity. By these means we characterized our YBa2Cu3O7 thin-film rf SQUIDs with step-edge junctions immersed in liquid N2. We obtained transfer function values of over 40 μV/Φ0, at a 50 Ω input impedance, for both hysteretic and dispersive mode of rf SQUID operation. The rms white and 1/f flux noise levels were significantly lower than at the tank frequency of 20 MHz. The best magnetic field sensitivity at 77 K was 0.9 pT/Hz1/2, and the energy resolution 1.4×10−28 J/Hz, down to 0.3 Hz.

Applied Physics Letters•Feb 3, 1992•83 citations

Operating characteristics of thin-film rf-biased SQUID’s

C. M. Falco, William H. Parker

Operating characteristics of rf-biased thin-film SQUID’s of diameter as large as 1 cm are reported. Observation on these SQUID’s have experimentally verified several of their conventionally assumed properties such as the dependence of the quantum interference signal on critical current of the weak link, total inductance of the SQUID, inductive coupling between drive coil and the SQUID, and random magnetic flux noise. A simple technique of lowering the inductance, and hence increasing the signal, of large-diameter SQUID’s is reported.

Journal of Applied Physics•Aug 1, 1975•22 citations

Substrate step-edge YBa2Cu3O7 rf SQUIDs

K.P. Daly, William D. Dozier, John F. Burch +4 more

We have developed a technique which permits high-yield fabrication of microbridges and low noise YBa2Cu3O7 superconducting quantum interference devices (SQUIDs) in epitaxial thin films. These SQUIDs operate over a wide temperature range extending from 4 K to close to the superconducting transition temperature. Measurements of an rf SQUID operating at 77 K give a peak-to-peak flux sensitivity of 36 μV/Φ0 and a flux noise at 10 Hz of 1.5× 10−4 Φ0/√Hz. Device yields over 80% have been obtained.

Applied Physics Letters•Feb 4, 1991•140 citations

Investigation and reduction of excess low-frequency noise in rf superconducting quantum interference devices

Michael Mück, Christoph Heiden, John Clarke

A detailed study has been made of the low-frequency excess noise of rf superconducting quantum interference devices (SQUIDs), fabricated from thin niobium films and operated at 4.2 K, with rf bias frequencies of 0.15, 1.7, and 3 GHz. When the SQUIDs were operated in an open-loop configuration in the absence of low-frequency flux modulation, the demodulated rf voltage exhibited a substantial level 1/f noise, which was essentially independent of the rf bias frequency. As the rf bias frequency was increased, the crossover frequency at which the 1/f noise power was equal to the white noise power moved to higher frequencies, because of the reduction in white noise. On the other hand, when the SQUID was flux modulated at 50 kHz and operated in a flux locked loop, no 1/f noise was observed at frequencies above 0.5 Hz. A detailed description of how the combination of rf bias and flux modulation removes 1/f noise due to critical current fluctuations is given. Thus, the results demonstrate that the 1/f noise observed in these SQUIDs is generated by critical current fluctuations, rather than by the hopping of flux vortices in the niobium films.

Journal of Applied Physics•May 1, 1994•27 citations

Operation of high-temperature rf SQUID magnetometers using dielectric SrTiO3 resonators

Y. Zhang, M. Gottschlich, Helmut Soltner +4 more

The operation of YBa2Cu3O7 rf superconducting quantum interference devices (SQUIDs) using a dielectric SrTiO3 resonator as tank circuit was tested. At 77 K, we attained for such resonators unloaded quality factors Q0 up to 7000 at resonant frequencies near 1 GHz, when measuring without electromagnetic shielding. For a washer SQUID with an area of 4×4 mm2 and an inductance of ≂100 pH, which was properly coupled to the resonator, we measured an approximately 60 μV peak-to-peak SQUID signal and a white flux noise spectral density of SΦ1/2=1×10−5Φ0/√Hz, corresponding to a field sensitivity of BN=105 fT/√Hz. With an additional single-layer flux transformer with a diameter of the pickup loop of 22 mm in flip-chip arrangement, the field sensitivity was improved to 30 fT/√Hz.

Applied Physics Letters•Nov 20, 1995•17 citations

1/f noise in radio frequency SQUIDs made of niobium thin films

Michael Mueck, John Clarke, Christoph Heiden

Applications of Superconducting Quantum Interference Devices (SQUIDs) usually require high sensitivity at relatively low frequencies, often down to 1 Hz or lower. Excess noise, typically with a spectral density scaling inversely as the frequency, can substantially reduce the sensitivity of SQUIDs at low frequencies. We have studied 1/f noise in niobium rf-SQUIDs in some detail. To reduce any noise contribution of the readout electronics, a cryogenic preamplifier was used. When one measures the signal voltage of the SQUID directly, a pronounced 1/f noise was observed in all samples, and was nearly independent of the bias frequency used. The crossover between 1/f and white noise moved towards higher frequencies as the bias frequency was increased, because of a lower white noise contribution. The 1/f noise scaled approximately as the inductance of the SQUID. When operated in a flux locked loop, however, no 1/f noise could be observed above 0.5 Hz. Operating a rf SQUID in a flux locked loop can thus substantially reduce 1/f noise in rf SQUIDs.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 2, 1994•0 citations
A new configuration, parallel operation of a number of rf SQUID elements provides enhanced sensitivity. This parallel operated elements has been fabricated by Nb thin film on single substrate, and drived by a single tank circuit. The variations of step pattern, interference pattern and flux sensitivity by increasing the number of elements have been measured. By performing parallel operation of four rf SQUID elements, the amplitude of interference pattern is increased two times as large as for single element case, and this agree well with theoretical analysis. Consequently, flux sensitivity is also enhanced similarly.
A superconducting quantum interferometer device (SQUID) electronics with tank frequencies near 150 MHz was constructed to enhance the rf SQUID sensitivity. By these means we characterized our YBa2Cu3O7 thin-film rf SQUIDs with step-edge junctions immersed in liquid N2. We obtained transfer function values of over 40 μV/Φ0, at a 50 Ω input impedance, for both hysteretic and dispersive mode of rf SQUID operation. The rms white and 1/f flux noise levels were significantly lower than at the tank frequency of 20 MHz. The best magnetic field sensitivity at 77 K was 0.9 pT/Hz1/2, and the energy resolution 1.4×10−28 J/Hz, down to 0.3 Hz.
Operating characteristics of rf-biased thin-film SQUID’s of diameter as large as 1 cm are reported. Observation on these SQUID’s have experimentally verified several of their conventionally assumed properties such as the dependence of the quantum interference signal on critical current of the weak link, total inductance of the SQUID, inductive coupling between drive coil and the SQUID, and random magnetic flux noise. A simple technique of lowering the inductance, and hence increasing the signal, of large-diameter SQUID’s is reported.
We have developed a technique which permits high-yield fabrication of microbridges and low noise YBa2Cu3O7 superconducting quantum interference devices (SQUIDs) in epitaxial thin films. These SQUIDs operate over a wide temperature range extending from 4 K to close to the superconducting transition temperature. Measurements of an rf SQUID operating at 77 K give a peak-to-peak flux sensitivity of 36 μV/Φ0 and a flux noise at 10 Hz of 1.5× 10−4 Φ0/√Hz. Device yields over 80% have been obtained.
A detailed study has been made of the low-frequency excess noise of rf superconducting quantum interference devices (SQUIDs), fabricated from thin niobium films and operated at 4.2 K, with rf bias frequencies of 0.15, 1.7, and 3 GHz. When the SQUIDs were operated in an open-loop configuration in the absence of low-frequency flux modulation, the demodulated rf voltage exhibited a substantial level 1/f noise, which was essentially independent of the rf bias frequency. As the rf bias frequency was increased, the crossover frequency at which the 1/f noise power was equal to the white noise power moved to higher frequencies, because of the reduction in white noise. On the other hand, when the SQUID was flux modulated at 50 kHz and operated in a flux locked loop, no 1/f noise was observed at frequencies above 0.5 Hz. A detailed description of how the combination of rf bias and flux modulation removes 1/f noise due to critical current fluctuations is given. Thus, the results demonstrate that the 1/f noise observed in these SQUIDs is generated by critical current fluctuations, rather than by the hopping of flux vortices in the niobium films.
The operation of YBa2Cu3O7 rf superconducting quantum interference devices (SQUIDs) using a dielectric SrTiO3 resonator as tank circuit was tested. At 77 K, we attained for such resonators unloaded quality factors Q0 up to 7000 at resonant frequencies near 1 GHz, when measuring without electromagnetic shielding. For a washer SQUID with an area of 4×4 mm2 and an inductance of ≂100 pH, which was properly coupled to the resonator, we measured an approximately 60 μV peak-to-peak SQUID signal and a white flux noise spectral density of SΦ1/2=1×10−5Φ0/√Hz, corresponding to a field sensitivity of BN=105 fT/√Hz. With an additional single-layer flux transformer with a diameter of the pickup loop of 22 mm in flip-chip arrangement, the field sensitivity was improved to 30 fT/√Hz.
Applications of Superconducting Quantum Interference Devices (SQUIDs) usually require high sensitivity at relatively low frequencies, often down to 1 Hz or lower. Excess noise, typically with a spectral density scaling inversely as the frequency, can substantially reduce the sensitivity of SQUIDs at low frequencies. We have studied 1/f noise in niobium rf-SQUIDs in some detail. To reduce any noise contribution of the readout electronics, a cryogenic preamplifier was used. When one measures the signal voltage of the SQUID directly, a pronounced 1/f noise was observed in all samples, and was nearly independent of the bias frequency used. The crossover between 1/f and white noise moved towards higher frequencies as the bias frequency was increased, because of a lower white noise contribution. The 1/f noise scaled approximately as the inductance of the SQUID. When operated in a flux locked loop, however, no 1/f noise could be observed above 0.5 Hz. Operating a rf SQUID in a flux locked loop can thus substantially reduce 1/f noise in rf SQUIDs.