Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Low-noise 1 THz niobium superconducting tunnel junction mixer with a normal metal tuning circuit

M. Bin, Michael C. Gaidis, Jonas Stasys Zmuidzinas, Tom G. Phillips, Henry George LeDuc

Published Mar 18, 1996• 97 citations
Publisher

Abstract

We describe a 1 THz quasioptical SIS mixer which uses a twin-slot antenna, an antireflection-coated silicon hyperhemispherical lens, Nb/Al-oxide/Nb tunnel junctions, and an aluminum normal-metal tuning circuit in a two-junction configuration. Since the mixer operates substantially above the gap frequency of niobium (ν≳2Δ/h∼700 GHz), a normal metal is used in the tuning circuit in place of niobium to reduce the Ohmic loss. The frequency response of the device was measured using a Fourier transform spectrometer and agrees reasonably well with the theoretical prediction. At 1042 GHz, the uncorrected double-sideband receiver noise temperature is 840 K when the physical temperature of the mixer is 2.5 K. This is the first SIS mixer which outperforms GaAs Schottky diode mixers by a large margin at 1 THz.

DOI
10.1063/1.115915

Related papers

Design and Characterization of a Quasi-Optical SIS Receiver for the 1 THz Band

M. Bin, Michael C. Gaidis, Daniel Miller +3 more

91101. Abstract—We report on the design and characterization of broadband quasi-optical SIS receirvers for the 1 THz frequency band. The mixer design utilizes a twin-slot antenna, an antirefiection-coated silicon hyperhemispherical lens, Nb/Al-oxide/Nb tunnel junctions, and an aluminum normal-metal tuning circuit in a two-junction configuration. The fre- quency response of the device was measured using a Fourier transform spectrometer and agrees reasonably well with the theoretical prediction. Heterodyne tests were carried out from 822-1042 GHz and low receiver noise temperatures of about 770 K were obtained after correcting the losses from the LO/signal beamsplitter.

Softwaretechnik-Trends•Mar 1, 1996•3 citations

Quasi-optical SIS mixers with normal metal tuning structures

Mei Bin, Michael C. Gaidis, Jonas Stasys Zmuidzinas +2 more

We recently reported (1996) a quasi-optical SIS mixer which used Nb/Al-oxide/Nb tunnel junctions and a normal-metal (Al) tuning circuit to achieve an uncorrected receiver noise temperature of 840 K (DSB) at 1042 GHz. Here we present results on several different device designs, which together cover the 300-1200 GHz frequency range. The mixers utilize an antireflection-coated silicon hyper-hemispherical lens, a twin-slot antenna, and a two-junction tuning circuit. The broad-band frequency response was measured using Fourier transform spectrometry (FTS), and is in good agreement with model calculations. Heterodyne tests were carried out from 400 GHz up to 1040 GHz, and these measurements agree well with the FTS results and with calculations based on Tucker's theory (1985).

IEEE Transactions on Applied Superconductivity•Jun 1, 1997•24 citations

Low-noise submillimeter-wave NbTiN superconducting tunnel junction mixers

Jonathan H. Kawamura, Jian Chen, David Miller +5 more

We have developed a low-noise 850 GHz superconductor–insulator–superconductor quasiparticle mixer with NbTiN thin-film microstrip tuning circuits and hybrid Nb/AlN/NbTiN tunnel junctions. The mixer uses a quasioptical configuration with a planar twin-slot antenna feeding a two-junction tuning circuit. At 798 GHz, we measured an uncorrected double-sideband receiver noise temperature of TRX=260 K at 4.2 K bath temperature. This mixer outperforms current Nb SIS mixers by a factor of nearly 2 near 800 GHz. The high-gap frequency and low loss at 800 GHz make NbTiN an attractive material with which to fabricate tuning circuits for SIS mixers. NbTiN mixers can potentially operate up to the gap frequency, 2Δ/h∼1.2 THz.

Applied Physics Letters•Dec 20, 1999•81 citations

Low-noise slot antenna SIS mixers

Jonas Stasys Zmuidzinas, N. G. Ugras, D. Miller +3 more

We describe quasi-optical SIS mixers operating in the submillimeter band (500-750 GHz) which have very low noise, around 5 h/spl nu//k/sub B/ for the double-sideband receiver noise temperature. The mixers use a twin-slot antenna, Nb/Al-Oxide/Nb tunnel junctions fabricated with optical lithography, a two-junction tuning circuit, and a silicon hyperhemispherical lens with a novel antireflection coating to optimize the optical efficiency. We have flown a submillimeter receiver using these mixers on the Kuiper Airborne Observatory, and have detected a transition of H/sub 2//sup 18/O at 745 GHz. This directly confirms that SIS junctions are capable of low-noise mixing above the gap frequency.>

IEEE Transactions on Applied Superconductivity•Jun 1, 1995•56 citations

Low-noise THz Niobium SIS Mixers

Mei Bin

This thesis describes the development of low-noise heterodyne receivers at THz frequencies for submillimeter astronomy using Nb-based superconductor-insulator-superconductor (SIS) tunneling junctions. The mixers utilize a quasi-optical configuration which consists of a planar twin-slot antenna and antisymmetrically-fed two-junctions on an antireflection-coated silicon hyperhemispherical lens. On-chip integrated tuning circuits, in the form of microstrip lines, are used to obtain maximum coupling efficiency in the designed frequency band. To reduce the rf losses in the integrated tuning circuits above the superconducting Nb gap frequency (~ 700 GHz), normal-metal Al is used to replace Nb as the tuning circuits. To account the rf losses in the micros trip lines, we calculated the surface impedance of the AI films using the nonlocal anomalous skin effect for finite thickness films. Nb films were calculated using the Mattis-Bardeen theory in the extreme anomalous limit. Our calculations show that the losses of the Al and Nb microstrip lines are about equal at 830 GHz. For Al-wiring and Nb-wiring mixers both optimized at 1050 GHz, the RF coupling efficiency of Al-wiring mixer is higher than that of Nb-wiring one by almost 50%. We have designed both Nb-wiring and Al-wiring mixers below and above the gap frequency. A Fourier transform spectrometer (FTS) has been constructed especially for the study of the frequency response of SIS receivers. This FTS features large aperture size (10 inch) and high frequency resolution (114 MHz). The FTS spectra, obtained using the SIS receivers as direct detectors on the FTS, agree quite well with our theoretical simulations. We have also, for the first time, measured the FTS heterodyne response of an SIS mixer at sufficiently high resolution to resolve the LO and the sidebands. Heterodyne measurements of our SIS receivers with Nb-wiring or Al-wiring have yielded results which arc among the best reported to date for broadband heterodyne receivers. The Nb-wiring mixers, covering 400 - 850 GHz band with four separate fixed-tuned mixers, have uncorrected DSB receiver noise temperature around 5hv/kb to 700 GHz, and better than 540 K at 808 GHz. An Al-wiring mixer designed for 1050 GHz band has an uncorrected DSB receiver noise temperature 840 K at 1042 GHz and 2.5 K bath temperature. Mixer performance analysis shows that Nb junctions can work well up to twice the gap frequency and the major cause of loss above the gap frequency is the rf losses in the microstrip tuning structures. Further advances in THz SIS mixers may be possible using circuits fabricated with higher-gap superconductors such as NbN. However, this will require high-quality films with low RF surface resistance at THz frequencies.

•Sep 1, 1997•8 citations

THz SIS mixers with normal-metal Al tuning circuits

M. Bin, Michael C. Gaidis, Jonas Stasys Zmuidzinas +2 more

Nb-based superconductor - insulator - superconductor (SIS) mixers with Nb tuning circuits have demonstrated good results up to the Nb gap frequency. Above the gap frequency the performance is expected to degrade quickly because RF loss in Nb becomes significant. In this paper we present the results of an effort to extend Nb-based SIS mixers to THz frequencies by employing lower-loss normal-metal Al wiring and tuning structures. The SIS mixer has two Nb/Al-oxide/Nb junctions connected by an Al microstrip inductor. The direct detection response of the device was measured by a Fourier transform spectrometer. A double-side-band receiver noise temperature of 840 K was obtained at 1042 GHz when the device was operated at 2.5 K.

Superconductor Science and Technology•Apr 1, 1996•5 citations
We describe a 1 THz quasioptical SIS mixer which uses a twin-slot antenna, an antireflection-coated silicon hyperhemispherical lens, Nb/Al-oxide/Nb tunnel junctions, and an aluminum normal-metal tuning circuit in a two-junction configuration. Since the mixer operates substantially above the gap frequency of niobium (ν≳2Δ/h∼700 GHz), a normal metal is used in the tuning circuit in place of niobium to reduce the Ohmic loss. The frequency response of the device was measured using a Fourier transform spectrometer and agrees reasonably well with the theoretical prediction. At 1042 GHz, the uncorrected double-sideband receiver noise temperature is 840 K when the physical temperature of the mixer is 2.5 K. This is the first SIS mixer which outperforms GaAs Schottky diode mixers by a large margin at 1 THz.
91101. Abstract—We report on the design and characterization of broadband quasi-optical SIS receirvers for the 1 THz frequency band. The mixer design utilizes a twin-slot antenna, an antirefiection-coated silicon hyperhemispherical lens, Nb/Al-oxide/Nb tunnel junctions, and an aluminum normal-metal tuning circuit in a two-junction configuration. The fre- quency response of the device was measured using a Fourier transform spectrometer and agrees reasonably well with the theoretical prediction. Heterodyne tests were carried out from 822-1042 GHz and low receiver noise temperatures of about 770 K were obtained after correcting the losses from the LO/signal beamsplitter.
We recently reported (1996) a quasi-optical SIS mixer which used Nb/Al-oxide/Nb tunnel junctions and a normal-metal (Al) tuning circuit to achieve an uncorrected receiver noise temperature of 840 K (DSB) at 1042 GHz. Here we present results on several different device designs, which together cover the 300-1200 GHz frequency range. The mixers utilize an antireflection-coated silicon hyper-hemispherical lens, a twin-slot antenna, and a two-junction tuning circuit. The broad-band frequency response was measured using Fourier transform spectrometry (FTS), and is in good agreement with model calculations. Heterodyne tests were carried out from 400 GHz up to 1040 GHz, and these measurements agree well with the FTS results and with calculations based on Tucker's theory (1985).
We have developed a low-noise 850 GHz superconductor–insulator–superconductor quasiparticle mixer with NbTiN thin-film microstrip tuning circuits and hybrid Nb/AlN/NbTiN tunnel junctions. The mixer uses a quasioptical configuration with a planar twin-slot antenna feeding a two-junction tuning circuit. At 798 GHz, we measured an uncorrected double-sideband receiver noise temperature of TRX=260 K at 4.2 K bath temperature. This mixer outperforms current Nb SIS mixers by a factor of nearly 2 near 800 GHz. The high-gap frequency and low loss at 800 GHz make NbTiN an attractive material with which to fabricate tuning circuits for SIS mixers. NbTiN mixers can potentially operate up to the gap frequency, 2Δ/h∼1.2 THz.
We describe quasi-optical SIS mixers operating in the submillimeter band (500-750 GHz) which have very low noise, around 5 h/spl nu//k/sub B/ for the double-sideband receiver noise temperature. The mixers use a twin-slot antenna, Nb/Al-Oxide/Nb tunnel junctions fabricated with optical lithography, a two-junction tuning circuit, and a silicon hyperhemispherical lens with a novel antireflection coating to optimize the optical efficiency. We have flown a submillimeter receiver using these mixers on the Kuiper Airborne Observatory, and have detected a transition of H/sub 2//sup 18/O at 745 GHz. This directly confirms that SIS junctions are capable of low-noise mixing above the gap frequency.>
This thesis describes the development of low-noise heterodyne receivers at THz frequencies for submillimeter astronomy using Nb-based superconductor-insulator-superconductor (SIS) tunneling junctions. The mixers utilize a quasi-optical configuration which consists of a planar twin-slot antenna and antisymmetrically-fed two-junctions on an antireflection-coated silicon hyperhemispherical lens. On-chip integrated tuning circuits, in the form of microstrip lines, are used to obtain maximum coupling efficiency in the designed frequency band. To reduce the rf losses in the integrated tuning circuits above the superconducting Nb gap frequency (~ 700 GHz), normal-metal Al is used to replace Nb as the tuning circuits. To account the rf losses in the micros trip lines, we calculated the surface impedance of the AI films using the nonlocal anomalous skin effect for finite thickness films. Nb films were calculated using the Mattis-Bardeen theory in the extreme anomalous limit. Our calculations show that the losses of the Al and Nb microstrip lines are about equal at 830 GHz. For Al-wiring and Nb-wiring mixers both optimized at 1050 GHz, the RF coupling efficiency of Al-wiring mixer is higher than that of Nb-wiring one by almost 50%. We have designed both Nb-wiring and Al-wiring mixers below and above the gap frequency. A Fourier transform spectrometer (FTS) has been constructed especially for the study of the frequency response of SIS receivers. This FTS features large aperture size (10 inch) and high frequency resolution (114 MHz). The FTS spectra, obtained using the SIS receivers as direct detectors on the FTS, agree quite well with our theoretical simulations. We have also, for the first time, measured the FTS heterodyne response of an SIS mixer at sufficiently high resolution to resolve the LO and the sidebands. Heterodyne measurements of our SIS receivers with Nb-wiring or Al-wiring have yielded results which arc among the best reported to date for broadband heterodyne receivers. The Nb-wiring mixers, covering 400 - 850 GHz band with four separate fixed-tuned mixers, have uncorrected DSB receiver noise temperature around 5hv/kb to 700 GHz, and better than 540 K at 808 GHz. An Al-wiring mixer designed for 1050 GHz band has an uncorrected DSB receiver noise temperature 840 K at 1042 GHz and 2.5 K bath temperature. Mixer performance analysis shows that Nb junctions can work well up to twice the gap frequency and the major cause of loss above the gap frequency is the rf losses in the microstrip tuning structures. Further advances in THz SIS mixers may be possible using circuits fabricated with higher-gap superconductors such as NbN. However, this will require high-quality films with low RF surface resistance at THz frequencies.
Nb-based superconductor - insulator - superconductor (SIS) mixers with Nb tuning circuits have demonstrated good results up to the Nb gap frequency. Above the gap frequency the performance is expected to degrade quickly because RF loss in Nb becomes significant. In this paper we present the results of an effort to extend Nb-based SIS mixers to THz frequencies by employing lower-loss normal-metal Al wiring and tuning structures. The SIS mixer has two Nb/Al-oxide/Nb junctions connected by an Al microstrip inductor. The direct detection response of the device was measured by a Fourier transform spectrometer. A double-side-band receiver noise temperature of 840 K was obtained at 1042 GHz when the device was operated at 2.5 K.