Efficient, low-noise, single-photon frequency conversion

Paulina S. Kuo, Jason S. Pelc, Oliver Slattery, Yong‐Su Kim, M. M. Fejer, Xiao Hong Tang

Published Jan 1, 2013• 1 citation
Publisher

Abstract

We demonstrate simultaneous low-noise and efficient frequency conversion in a periodically poled LiNbO3 waveguide with spectral filtering. We achieve >50% external conversion efficiency and 600 noise counts per second at peak conversion.
DOI
10.1364/cleo_qels.2013.jth2a.86

Related papers

Reducing noise in single-photon-level frequency conversion

Paulina S. Kuo, Jason S. Pelc, Oliver Slattery +3 more

We demonstrate low-noise and efficient frequency conversion by sum-frequency mixing in a periodically poled LiNbO(3) (PPLN) waveguide. Using a 1556 nm pump, 1302 nm photons are efficiently converted to 709 nm photons. We obtain 70% conversion efficiency in the PPLN waveguide and >50% external conversion efficiency with 600 noise counts per second at peak conversion with continuous-wave pumping. We simultaneously achieve low noise and high conversion efficiency by careful spectral filtering. We discuss the impact of low-noise frequency translation on single-photon upconversion detection and quantum information applications.

Optics Letters•Apr 9, 2013•63 citations

Single-photon detector based on frequency up-conversion in MgO-doped periodically-poled LiNbO3 waveguide: Record-low dark counts and detectable photons

Li -, Ding Ding, Зотова +1 more

Conference on Lasers and Electro-Optics•Jan 1, 2012•0 citations

Ultra low dark-count-rate up-conversion single photon detector

Xiao Hong Tang, Lijun Ma, Oliver Slattery

We have demonstrated an ultra low noise up-conversion single photon detector using a periodically poled lithium niobate waveguide. The dark count rate of this detector is lower than 100 counts/second at 10% detection efficiency.

IEEE Photonics Society Annual Meeting•Nov 1, 2010•3 citations

Low noise single photon frequency upconversion using Ti-indiffused periodically-poled lithium niobate waveguides with efficient narrowband filtering

Zhenda Xie, Kai-Hong Luo, Harald Herrmann +2 more

We demonstrate single-photon frequency-upconversion using a titanium-infused periodically-poled lithium niobate waveguide by L-band erbium-doped fiber amplifier pump. Internal efficiencies up to 84.4% and dark-count rate of 44kHz are achieved with narrowband filtering down to 3.5GHz.

•Jan 1, 2015•1 citation

Single-photon detector based on frequency up-conversion in MgO-doped periodically-poled LiNbO3 waveguide: recordlow dark counts and detectable photons

Da Li, Yujie J. Ding, Ioulia B. Zotova +1 more

We have implemented a single-photon detector in the 1500-nm band based on frequency up-conversion in a MgO-doped periodically-poled LiNbO3 waveguide, with a record-low dark count rate and a record-low detectable signal photon rate.

Conference on Lasers and Electro-Optics•Jan 1, 2012•0 citations

Frequency up-conversion at the single-photon level in a periodically-poled lithium-niobate waveguide

Sarah Dugan, X. Li, Paul L. Voss +1 more

Using sum-frequency generation we fully up-convert signal photons at 1550 nm to 775 nm. Due to coupling and filtering losses at the output, overall quantum efficiency is /spl sime/3.4% with dark-count probability of 3%.

Quantum Electronics and Laser Science Conference•Dec 10, 2005•2 citations
We demonstrate low-noise and efficient frequency conversion by sum-frequency mixing in a periodically poled LiNbO(3) (PPLN) waveguide. Using a 1556 nm pump, 1302 nm photons are efficiently converted to 709 nm photons. We obtain 70% conversion efficiency in the PPLN waveguide and >50% external conversion efficiency with 600 noise counts per second at peak conversion with continuous-wave pumping. We simultaneously achieve low noise and high conversion efficiency by careful spectral filtering. We discuss the impact of low-noise frequency translation on single-photon upconversion detection and quantum information applications.