Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physica

Some characteristics of a maser at 1420 MHz

Bouwe Bolger, B.J. Robinson, J. Ubbink

Published Jan 1, 1960• 37 citations
Publisher
DOI
10.1016/0031-8914(60)90109-9

Related papers

Characteristics of stationary maser generation in the case of a polarizing pump

O. A. Kocherovskaia, V. B. Tsaregradskii

Radiophysics and Quantum Electronics•Jan 1, 1984•0 citations

Hg/sup +/ trapped ion standard with the superconducting cavity maser oscillator

John D. Prestage, Robert L. Tjoelker, R.T. Wang +2 more

The frequency stability of an atomic standard based on /sup 199/Hg/sup +/ ions confined in a hybrid RF/DC linear trap is described. The 40.5-GHz clock transition has been measured to be 17 mHz wide, representing a quality factor greater than 2*10/sup 12/. A 160-mHz line is used to steer the output of a 5-MHz crystal oscillator to obtain a stability of 2*10/sup -15/ for 24000-s averaging times. In a separate measurement, a 37-mHz line is used to steer the output of the superconducting cavity maser oscillator to reach 1*10/sup -15/ stability at 10000 s.>

IEEE Transactions on Instrumentation and Measurement•Apr 1, 1993•13 citations

Experimental demonstration of the anti-maser

Anthony Mazzocco, Michael Avilés, Jim Andrews +2 more

Bulletin of the American Physical Society•Oct 6, 2012•0 citations

Trivalent-iron-doped andalusite as crystal for microwave waves

I. I. Eru, S. A. Peskovatskiǐ, A. Chernets

Paramagnetic ions Fe3+, substituted as an impurity in andalusite (Al2SiO5) host crystals, have been experimentally investigated. The spin-lattice relaxation and cross-relaxation times and inversion ratio in this spin system were observed. Dielectric properties of the host crystals were determined. General maser properties of trivalent-iron-doped andalusite crystal are discussed. Two types of the andalusite cavity masers are described. TheX-band three-level maser operates at a temperature of 2.1°K and a magnetic field of 1400 gauss. Electronic gains of 25 dB and instantaneous bandwidth of 3.5 \pm 0.5 MHz, at the frequency of 9.45 GHz, were obtained. TheF-band push-pull maser operates at a temperature of 2.1°K and a magnetic field of 2800 gauss. Electronic gains of 30 dB and instantaneous bandwidth of 5.5 ± 0.5 MHZ, at the frequency of 100.4 GHz, were obtained.

IEEE Journal of Quantum Electronics•Nov 1, 1968•13 citations

Proposal for a New Type Solid State Maser

N. BLOEMBERGEN

Elsevier eBooks•Jan 1, 1970•2 citations

Hg/sup +/ trapped ion standard performance with the superconducting cavity maser oscillator as LO

John D. Prestage, Robert L. Tjoelker, R.T. Wang +2 more

The frequency stability obtained with an ion-trap-based frequency standard where /sup 199/Hg/sup +/ ions are confined in a hybrid RF/DC linear trap is described. The 40.5-GHz clock transition is measured to be as narrow as 17 mHz representing a quality factor of 2.4*10/sup 12/. A hydrogen maser interrogation of a 37-mHz Hg/sup +/ resonance is used to measure 1*10/sup -15/ stability of the ion resonance at 10000-s averaging time. In another measurement the frequency of the superconducting cavity maser oscillator is steered to follow the Hg/sup +/ clock transition, again providing frequency stability of 1*10/sup -15/ at 10000-s.>

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 2, 2003•11 citations
The frequency stability of an atomic standard based on /sup 199/Hg/sup +/ ions confined in a hybrid RF/DC linear trap is described. The 40.5-GHz clock transition has been measured to be 17 mHz wide, representing a quality factor greater than 2*10/sup 12/. A 160-mHz line is used to steer the output of a 5-MHz crystal oscillator to obtain a stability of 2*10/sup -15/ for 24000-s averaging times. In a separate measurement, a 37-mHz line is used to steer the output of the superconducting cavity maser oscillator to reach 1*10/sup -15/ stability at 10000 s.>
Paramagnetic ions Fe3+, substituted as an impurity in andalusite (Al2SiO5) host crystals, have been experimentally investigated. The spin-lattice relaxation and cross-relaxation times and inversion ratio in this spin system were observed. Dielectric properties of the host crystals were determined. General maser properties of trivalent-iron-doped andalusite crystal are discussed. Two types of the andalusite cavity masers are described. TheX-band three-level maser operates at a temperature of 2.1°K and a magnetic field of 1400 gauss. Electronic gains of 25 dB and instantaneous bandwidth of 3.5 \pm 0.5 MHz, at the frequency of 9.45 GHz, were obtained. TheF-band push-pull maser operates at a temperature of 2.1°K and a magnetic field of 2800 gauss. Electronic gains of 30 dB and instantaneous bandwidth of 5.5 ± 0.5 MHZ, at the frequency of 100.4 GHz, were obtained.
The frequency stability obtained with an ion-trap-based frequency standard where /sup 199/Hg/sup +/ ions are confined in a hybrid RF/DC linear trap is described. The 40.5-GHz clock transition is measured to be as narrow as 17 mHz representing a quality factor of 2.4*10/sup 12/. A hydrogen maser interrogation of a 37-mHz Hg/sup +/ resonance is used to measure 1*10/sup -15/ stability of the ion resonance at 10000-s averaging time. In another measurement the frequency of the superconducting cavity maser oscillator is steered to follow the Hg/sup +/ clock transition, again providing frequency stability of 1*10/sup -15/ at 10000-s.>