Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Scientific Reports

Classical Imaging with Undetected Photons

Jeffrey H. Shapiro, Dheera Venkatraman, Franco N. C. Wong

Published May 27, 2015• 43 citations
Publisher

Abstract

Barreto Lemos et al. [Nature 512, 409-412 (2014)] reported an experiment in which a non-degenerate parametric downconverter and a non-degenerate optical parametric amplifier--used as a wavelength-converting phase conjugator--were employed to image object transparencies in a manner akin to ghost imaging. Their experiment, however, relied on single-photon detection, rather than the photon-coincidence measurements employed in ghost imaging with a parametric downconverter source. More importantly, their system formed images despite the photons that passed through the object never being detected. Barreto Lemos et al. interpreted their experiment as a quantum imager, as assuredly it is, owing to its downconverter's emitting entangled signal and idler beams. We show, however, that virtually all the features of their setup can be realized in a quantum-mimetic fashion using classical-state light, specifically a pair of bright pseudothermal beams possessing a phase-sensitive cross correlation. Owing to its much higher signal-to-noise ratio, our bright-source classical imager could greatly reduce image-acquisition time compared to that of Barreto Lemos et al.'s quantum system, while retaining the latter's ability to image with undetected photons.

DOI
10.1038/srep10329

Related papers

Classical Imaging with Undetected Photons

Jeffrey H. Shapiro, Dheera Venkatraman, Franco N. C. Wong

We describe a classical-state system capable of mimicking the essential features of Barreto Lemos et al.'s quantum imaging with undetected photons [Nature, 512, 409-412 (2014)], but with a much higher signal-to-noise ratio.

Conference on Lasers and Electro-Optics•Jan 1, 2015•8 citations

Quantum Ghost Image Identification with Correlated Photon Pairs

Mehul Malik, Heedeuk Shin, Malcolm N. O’Sullivan +2 more

Ghost imaging can be performed using either quantum or classical states of light that possess strong spatial correlations. In both cases, the image is formed by averaging over many optical events. Here we show that it is possible to distinguish an object from a preestablished basis set of objects by using a small number of position-correlated photon pairs produced by spontaneous parametric down-conversion. The signal photon is incident on one member of a set of spatially nonoverlapping objects. The "ghost" image information is impressed upon the spatially separated idler photon and is extracted by means of holographic filtering and coincidence detection. We were able to distinguish among sets of two and four spatially nonoverlapping objects with confidence levels higher than 87% and 81%, respectively. This method of ghost imaging can be performed in situations requiring extremely low light levels.

Physical Review Letters•Apr 23, 2010•50 citations

Quantum differential ghost microscopy

Elena Losero, Ivano Ruo Berchera, Alice Meda +3 more

Quantum correlations become formidable tools for beating classical capacities of measurement. Preserving these advantages in practical systems, where experimental imperfections are unavoidable, is a challenge of the utmost importance. Here we propose and realize a quantum ghost imaging protocol stemming from the differential ghost imaging, a scheme elaborated so far in the limit of bright thermal light, particularly suitable in the relevant case of faint or sparse objects. The extension toward the quantum regime represents an important step as quantum correlations allow low-brightness imaging, desirable for reducing the absorption dose. Furthermore, we optimize the protocol in terms of signal-to-noise ratio, to compensate for the detrimental effects of detection noise and losses. We perform the experiment using spontaneous parametric down conversion light in a microscope configuration. The image is reconstructed exploiting nonclassical intensity correlation in the low photon flux regime, rather than photon pairs detection coincidences. On the one side, we validate the theoretical model and on the other we show the applicability of this technique by imaging biological samples.

arXiv:1903.12630•Physical Review A•Dec 10, 2019•24 citations

Ghost imaging with zero photons

Meixue Chen, Yiqi Song, Yu Gu +8 more

Ghost imaging was first demonstrated with entangled photon pairs and well-known for its peculiar properties. The signal beam that illuminates the object possesses no spatial resolution, whereas the reference beam, which never interacts with the object, is spatially resolved. Either beam alone cannot retrieve the image, which can only be obtained when the signal and reference beams are correlated. Here we will report a ghost imaging experiment with even more peculiar properties, in which the image can be reconstructed when no photon interacts with the object or even no photon in neither signal nor reference beam. All the photons interacted with the object are discarded. Only the time bins with zero photon are employed to retrieve the image, a process referred to as "ghost imaging with zero photons" hereafter. The reason why ghost image can be retrieved with zero photons is jointly determined by photon-number projection measurement and photon statistics of thermal light. The results are helpful to resolve the debate on the physics of ghost imaging and understand the relation between quantum and classical correlations.

quant-pharXiv:2604.07782•Physical Review A•Apr 10, 2026•2 citations

Classical imaging with undetected light

Arthur C. Cardoso, L. P. Berruezo, Denise F. Ávila +5 more

We obtained the phase and intensity images of an object by detecting classical light which never interacted with it. With a double passage of a pump and a signal laser beams through a nonlinear crystal, we observe interference between the two idler beams produced by stimulated parametric down conversion. The object is placed in the amplified signal beam after its first passage through the crystal and the image is observed in the interference of the generated idler beams. High contrast images can be obtained even for objects with small transmittance coefficient due to the geometry of the interferometer and to the stimulated parametric emission. Like its quantum counterpart, this three-color imaging concept can be useful when the object must be probed with light at a wavelength for which detectors are not available.

arXiv:1801.09101•Physical Review A•Mar 16, 2018•47 citations

Quantum-enhanced imaging and metrology with undetected photons via squeezed-light homodyne detection

S. Samimi, Zahra Ghasemi, Hamidreza Mohammadi

In this work a quantum imaging setup based on undetected squeezed photons is employed for metrological applications such as sensitive phase measurement and quantum imaging. Unlike traditional quantum imaging with undetected photons, as introduced by A. Zeilinger et al., the proposed setup incorporates a homodyne detection system and enhances the brightness of the quantum light using optical parametric oscillators (OPOs). The inclusion of OPOs may challenge the validity of the low-gain approximation, necessitating the development of a new theoretical framework that extends beyond this approximation. The results demonstrate a higher signal-to-noise ratio, which serves as a key metric for both image quality and phase-measurement accuracy. Furthermore, an imaging protocol is introduced to effectively suppress background noise. Notably, this protocol enables the extraction of image information encoded in quantum fluctuations (noise), paving the way for non-disruptive imaging. This is particularly significant in the field of bio-imaging, since the object (a sensitive living cell) is interrogated by longer-wavelength idler light while detection is applied at optical frequency in which the sensors are less noisy and has more quantum efficiency.

arXiv:2411.05175•Scientific Reports•Dec 2, 2025•5 citations
Barreto Lemos et al. [Nature 512, 409-412 (2014)] reported an experiment in which a non-degenerate parametric downconverter and a non-degenerate optical parametric amplifier--used as a wavelength-converting phase conjugator--were employed to image object transparencies in a manner akin to ghost imaging. Their experiment, however, relied on single-photon detection, rather than the photon-coincidence measurements employed in ghost imaging with a parametric downconverter source. More importantly, their system formed images despite the photons that passed through the object never being detected. Barreto Lemos et al. interpreted their experiment as a quantum imager, as assuredly it is, owing to its downconverter's emitting entangled signal and idler beams. We show, however, that virtually all the features of their setup can be realized in a quantum-mimetic fashion using classical-state light, specifically a pair of bright pseudothermal beams possessing a phase-sensitive cross correlation. Owing to its much higher signal-to-noise ratio, our bright-source classical imager could greatly reduce image-acquisition time compared to that of Barreto Lemos et al.'s quantum system, while retaining the latter's ability to image with undetected photons.
Ghost imaging can be performed using either quantum or classical states of light that possess strong spatial correlations. In both cases, the image is formed by averaging over many optical events. Here we show that it is possible to distinguish an object from a preestablished basis set of objects by using a small number of position-correlated photon pairs produced by spontaneous parametric down-conversion. The signal photon is incident on one member of a set of spatially nonoverlapping objects. The "ghost" image information is impressed upon the spatially separated idler photon and is extracted by means of holographic filtering and coincidence detection. We were able to distinguish among sets of two and four spatially nonoverlapping objects with confidence levels higher than 87% and 81%, respectively. This method of ghost imaging can be performed in situations requiring extremely low light levels.
Quantum correlations become formidable tools for beating classical capacities of measurement. Preserving these advantages in practical systems, where experimental imperfections are unavoidable, is a challenge of the utmost importance. Here we propose and realize a quantum ghost imaging protocol stemming from the differential ghost imaging, a scheme elaborated so far in the limit of bright thermal light, particularly suitable in the relevant case of faint or sparse objects. The extension toward the quantum regime represents an important step as quantum correlations allow low-brightness imaging, desirable for reducing the absorption dose. Furthermore, we optimize the protocol in terms of signal-to-noise ratio, to compensate for the detrimental effects of detection noise and losses. We perform the experiment using spontaneous parametric down conversion light in a microscope configuration. The image is reconstructed exploiting nonclassical intensity correlation in the low photon flux regime, rather than photon pairs detection coincidences. On the one side, we validate the theoretical model and on the other we show the applicability of this technique by imaging biological samples.
Ghost imaging was first demonstrated with entangled photon pairs and well-known for its peculiar properties. The signal beam that illuminates the object possesses no spatial resolution, whereas the reference beam, which never interacts with the object, is spatially resolved. Either beam alone cannot retrieve the image, which can only be obtained when the signal and reference beams are correlated. Here we will report a ghost imaging experiment with even more peculiar properties, in which the image can be reconstructed when no photon interacts with the object or even no photon in neither signal nor reference beam. All the photons interacted with the object are discarded. Only the time bins with zero photon are employed to retrieve the image, a process referred to as "ghost imaging with zero photons" hereafter. The reason why ghost image can be retrieved with zero photons is jointly determined by photon-number projection measurement and photon statistics of thermal light. The results are helpful to resolve the debate on the physics of ghost imaging and understand the relation between quantum and classical correlations.
We obtained the phase and intensity images of an object by detecting classical light which never interacted with it. With a double passage of a pump and a signal laser beams through a nonlinear crystal, we observe interference between the two idler beams produced by stimulated parametric down conversion. The object is placed in the amplified signal beam after its first passage through the crystal and the image is observed in the interference of the generated idler beams. High contrast images can be obtained even for objects with small transmittance coefficient due to the geometry of the interferometer and to the stimulated parametric emission. Like its quantum counterpart, this three-color imaging concept can be useful when the object must be probed with light at a wavelength for which detectors are not available.
In this work a quantum imaging setup based on undetected squeezed photons is employed for metrological applications such as sensitive phase measurement and quantum imaging. Unlike traditional quantum imaging with undetected photons, as introduced by A. Zeilinger et al., the proposed setup incorporates a homodyne detection system and enhances the brightness of the quantum light using optical parametric oscillators (OPOs). The inclusion of OPOs may challenge the validity of the low-gain approximation, necessitating the development of a new theoretical framework that extends beyond this approximation. The results demonstrate a higher signal-to-noise ratio, which serves as a key metric for both image quality and phase-measurement accuracy. Furthermore, an imaging protocol is introduced to effectively suppress background noise. Notably, this protocol enables the extraction of image information encoded in quantum fluctuations (noise), paving the way for non-disruptive imaging. This is particularly significant in the field of bio-imaging, since the object (a sensitive living cell) is interrogated by longer-wavelength idler light while detection is applied at optical frequency in which the sensors are less noisy and has more quantum efficiency.