We have investigated the process of quenching of fluorescence from the
3P0 excited state of
Pr3+ in La
F3 due to cross relaxation among the Pr ions. The fluorescence decay of the ensemble of Pr ions after pulsed excitation is measured as a function of temperature for Pr concentration of 20 mol%. About 12% of the ions are in nonquenching sites and contribute an exponential component to the decay. The remainder of the decay originates from the bulk of the ions in quenching sites. Cross relaxation occurs directly in steps after transfer within the inhomogeneous line. Knowledge of the dynamics occurring within the inhomogeneous line derived from fluorescence line-narrowing experiments is used to analyze the cross-relaxation process from a microscopic viewpoint based on a recent model for fluorescence in the presence of traps. At 2 K the decay is consistent with an electric dipole-dipole transfer mechanism with a nearest-neighbor quenching rate of 8.9 \ifmmode\times\else\texttimes\fi{}
104 ${\mathrm{s}}^{\ensuremath{-}1}$ which is independent of temperature for
T<32 K and which successfully predicts the observed decay rate in Pr
F3. The temperature dependence of the decay for $8\ensuremath{\le}T\ensuremath{\le}32$ K is well described by a hopping model for excitation trapping. For
T>35 K an activation process becomes dominant consistent with the onset of cross relaxation involving the
1D2(5) and
3H6(1) states in which a 190-${\mathrm{cm}}^{\ensuremath{-}1}$ phonon is created.
The fluorescence intensities and lifetimes of various no-phonon lines in ruby samples with 2.1 and 0.94%
Cr3+ were studied from 13 to 700\ifmmode^\circ\else\textdegree\fi{}K. The temperature dependences of the intensities of numerous lines were used to determine the energy levels of two pair systems. The relative intensities of the single-ion (
R) lines and the pair (
N) lines are proportional to Boltzmann factors ${e}^{\frac{\ensuremath{-}\ensuremath{\Delta}E}{\mathrm{kT}}}$, where $\ensuremath{\Delta}E$ is the difference in energy of the metastable states, at high temperatures but not at low temperatures. The deviation from this law is greater and occurs at higher temperatures in the less concentrated sample. The fluorescence decays of the
R and
N lines are pure exponentials in the temperature region where the
N lines follow a Boltzmann law; at low temperatures the
N lines have an initial rise in fluorescence and then a decay. These results are interpreted in terms of coupled fluorescence systems consisting of single ions and pairs. A phonon-assisted cross-relaxation coupling process is suggested which allows for thermalization of the systems at high temperatures and direct pumping of the pair systems by the single-ion system at low temperatures. Energy transfer from single-ion to multi-ion systems was also observed.
We have found direct evidence of upward, phonon annihilation, processes in the decay patterns of two metastable states $^{5}D_{0}(14542 {\mathrm{cm}}^{\ensuremath{-}1})$ and $^{5}D_{1}(15878 {\mathrm{cm}}^{\ensuremath{-}1})$ of BaClF:
Sm2+. Under pulse excitation, the decay curve of the
5D1 fluorescence includes a long tail, with a time constant equal to the lifetime of
5D0, which appears at \ensuremath{\sim}280\ifmmode^\circ\else\textdegree\fi{}K and grows in intensity with temperature; finally at \ensuremath{\sim}400\ifmmode^\circ\else\textdegree\fi{}K both states decay with the same time constant. This finding is consistent with the thermal dependence of the ratio of the intensities of the
5D1 to the
5D0 flourescence.