Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

AIP conference proceedings

Coherent Population Trapping for Continuous and Alternating Magnetic Fields Measurements

Dimitar G. Slavov, G. Bevilacqua, V. Biancalana, S. Cartaleva, Yordanka V. Dancheva, Todor S. Karaulanov, L. Moi, Nikolay Petrov, Andrey Yanev

Published Jan 1, 2007• 1 citation
Publisher

Abstract

Coherent Population Trapping resonances on the D2 line of Cs are examined under the influence of continuous and alternating magnetic fields. It is shown that alternating fields as low as a fraction of μT modifies significantly the shape of the resonances, which can be used for oscillating magnetic field measurement.
DOI
10.1063/1.2733093

Related papers

Coherent Population Trapping for Electromagnetic Field Measurement

C. Andreeva, G. Bevilacqua, V. Biancalana +7 more

Coherent population trapping resonances at the D2line of Cs are examined under the influence of constant and alternating magnetic fields. It is shown that electromagnetic fields as low as a few mG modify significantly the shape of the resonances, which can be used for electromagnetic field measurement

Conference on Precision Electromagnetic Measurements•Jun 1, 2004•0 citations

Single frequency coherent-population-trapping resonances for magnetic field measurement

S. Gateva, Emilia A. Alipieva, L. Petrov +2 more

Experimental investigation of the width, amplitude and shape of the Coherent Population Trapping (CPT) resonances for magnetic field measurements by means of a Hanle effect configuration (the single frequency CPT resonances) is presented. Different resonance width narrowing effects for increasing the sensitivity of the magnetometers are discussed. Numerical simulations based on density matrix formalism, which take into account the influence of the high rank polarization moments and the velocity distribution of the atoms have been performed for analysis of the shapes of the resonances.

Journal of Optoelectronics and Advanced Materials•Jan 1, 2008•5 citations

Coherent Population Trapping Spectra in Presence of ac Magnetic Fields

G. Bevilacqua, V. Biancalana, Evelina Breschi +5 more

Experimental and theoretical investigations are reported on the effects induced by an alternating magnetic field on coherent population trapping resonances. We show that the ac magnetic field produces sidebands of these resonances in such a way that the spectrum observed is similar to those observed via the FM spectroscopic technique. Because of the very narrow linewidth of the resonances, sidebands are resolved even for ac field frequencies as low as a fraction of a kHz. The theoretical model developed, which takes into account a very simple atomic structure, fits the experimental data quite well.

Physical Review Letters•Sep 14, 2005•10 citations

Magnetic field influence on coherent resonance in a degenerate two-level system

Emilia A. Alipieva, S. Gateva, Elena T. Taskova +2 more

Coherent population trapping (CPT) resonances in the degenerate two-level system of the Fg = 2 → Fe = 1) transition of the 87Rb D1 line were investigated in an uncoated vacuum cell by means of Hanle effect configuration. CPT signals with complex shape (narrow resonance approximately 2 mG superimposed on the wide one approximately 150 mG) were observed. The influence of weak transverse magnetic fields (0-1.2 G) on the amplitude and width of the two components was measured. The observed narrow resonances are interesting for application in high resolution spectroscopy and magnetometry.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 6, 2003•5 citations

Potential of the Single-Frequency CPT Resonances for Magnetic Field Measurement

Emilia A. Alipieva, S. Gateva, Elena T. Taskova

Coherent population trapping (CPT) resonances on degenerate two-level system of D/sub 1/ line of /sup 87/Rb were investigated with single-frequency laser excitation in Hanle configuration. Their sensitivity to stray magnetic fields was examined for linear, elliptical, and circular laser polarization. A methodology for magnetic field (MF) measurement using the CPT resonance is proposed. The sensitivity of the system to weak magnetic fields was evaluated and a magnetic field of 3 nT was unambiguously detected.

IEEE Transactions on Instrumentation and Measurement•Mar 21, 2005•16 citations

Coherent population trapping resonance on degenerate two-level system for magnetic field measurement

Emilia A. Alipieva, S. Gateva, Elena T. Taskova

Coherent population trapping (CPT) resonances on the degenerate two-level system of the (Fg=2→Fe=1) transition of the 87Rb D1 line were investigated in an uncoated vacuum cell by means of level-crossing type experiments-sweeping a magnetic field around zero value and using a single laser beam. The two-photon resonance manifests itself as fluorescence canceling when the system of levels is degenerate (at zero point of magnetic field). The influence of weak transverse magnetic fields on the amplitude and width of the resonance was investigated. The CPT resonances were observed with linear, circular and elliptical polarized laser light. Transverse magnetic field widens the resonances obtained by linear and circular polarization but splits the resonance created by slightly elliptically polarized laser light. The dependence of this splitting on the elliptical ratio and experimental geometry were investigated. Due to its narrow width and sensitivity to low magnetic fields (< 1 G) this resonance is very promising for small magnetic field measurement.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jun 21, 2004•6 citations
Experimental investigation of the width, amplitude and shape of the Coherent Population Trapping (CPT) resonances for magnetic field measurements by means of a Hanle effect configuration (the single frequency CPT resonances) is presented. Different resonance width narrowing effects for increasing the sensitivity of the magnetometers are discussed. Numerical simulations based on density matrix formalism, which take into account the influence of the high rank polarization moments and the velocity distribution of the atoms have been performed for analysis of the shapes of the resonances.
Experimental and theoretical investigations are reported on the effects induced by an alternating magnetic field on coherent population trapping resonances. We show that the ac magnetic field produces sidebands of these resonances in such a way that the spectrum observed is similar to those observed via the FM spectroscopic technique. Because of the very narrow linewidth of the resonances, sidebands are resolved even for ac field frequencies as low as a fraction of a kHz. The theoretical model developed, which takes into account a very simple atomic structure, fits the experimental data quite well.
Coherent population trapping (CPT) resonances in the degenerate two-level system of the Fg = 2 → Fe = 1) transition of the 87Rb D1 line were investigated in an uncoated vacuum cell by means of Hanle effect configuration. CPT signals with complex shape (narrow resonance approximately 2 mG superimposed on the wide one approximately 150 mG) were observed. The influence of weak transverse magnetic fields (0-1.2 G) on the amplitude and width of the two components was measured. The observed narrow resonances are interesting for application in high resolution spectroscopy and magnetometry.
Coherent population trapping (CPT) resonances on degenerate two-level system of D/sub 1/ line of /sup 87/Rb were investigated with single-frequency laser excitation in Hanle configuration. Their sensitivity to stray magnetic fields was examined for linear, elliptical, and circular laser polarization. A methodology for magnetic field (MF) measurement using the CPT resonance is proposed. The sensitivity of the system to weak magnetic fields was evaluated and a magnetic field of 3 nT was unambiguously detected.
Coherent population trapping (CPT) resonances on the degenerate two-level system of the (Fg=2→Fe=1) transition of the 87Rb D1 line were investigated in an uncoated vacuum cell by means of level-crossing type experiments-sweeping a magnetic field around zero value and using a single laser beam. The two-photon resonance manifests itself as fluorescence canceling when the system of levels is degenerate (at zero point of magnetic field). The influence of weak transverse magnetic fields on the amplitude and width of the resonance was investigated. The CPT resonances were observed with linear, circular and elliptical polarized laser light. Transverse magnetic field widens the resonances obtained by linear and circular polarization but splits the resonance created by slightly elliptically polarized laser light. The dependence of this splitting on the elliptical ratio and experimental geometry were investigated. Due to its narrow width and sensitivity to low magnetic fields (< 1 G) this resonance is very promising for small magnetic field measurement.