Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics and Spectroscopy

Effect of a magnetic field on two-photon absorption spectra recorded by intracavity spectroscopy

А. П. Войтович, А. Ч. Измайлов, О. Е. Костик, В. В. Машко

Published Mar 1, 1989• 0 citations
OpenAlex

Related papers

Influence of coherence effects on absorption measurements by the intracavity-spectroscopy method

V. S. Egorov, Чехонин Игорь Анатольевич

Optics and Spectroscopy•Apr 1, 1982•2 citations

High-resolution spectroscopy of weakly absorbing objects based on a competing beam method

Sergei A. Batishche, Vasili A. Mostovnikov, Anatolii N Rubinov

A new competing beam method is proposed for intracavity measurement of weak absorption. In this method two independent lasers with the same active medium are employed. An investigated sample is placed inside the resonator of one of the lasers with a narrow tunable emission line. In contrast to the selective intracavity absorption method, photoelectric recording of the spectra can be used in the proposed method and this can be done for narrow lines as well as for wide absorption bands. Moreover, the new method can be used to determine the two-photon absorption spectra.

Soviet Journal of Quantum Electronics•Nov 30, 1976•3 citations

Magnetic field effect on the spectral components of the hyperfine structure of two-photon transitions

А. Ч. Измайлов

OptSp•Mar 1, 1988•0 citations

Loss of spectral memory in the relaxation oscillations of a multimode solid-state laser

D. Romanini, Alexander A. Kachanov, Éric Lacot +1 more

To test the application of solid-state lasers to intracavity laser absorption spectroscopy (ICLAS), we studied a neodymium-doped glass laser, in the presence of extreme relaxation oscillations (up to ${10}^{8}$ intensity contrast). The contrast of these oscillations could be varied by changing the Q-switch transition time. The recorded absorption spectra accurately follow the regular ICLAS behavior except when the intensity in the first relaxation oscillation minimum becomes too low. In such a case, we find that the ICLAS absorption spectrum accumulated during the first spike is ``forgotten'' by the system. Numerical simulations were done which accurately describe the observed transition to a regime of memory loss, when the number of photons circulating in each mode drops close to 1. These simulations show that the mechanism of memory loss is the prevailing of spontaneous over stimulated emission. This effect sets the fundamental limit of the sensitivity of an ICLAS spectrometer where the nonlinear mode interactions are negligible. This effect was observed before only in a diode laser system with high internal losses. In this paper we report an observation of ICLAS sensitivity saturation by spontaneous emission during relaxation oscillations in a laser with low cavity losses. \textcopyright{} 1996 The American Physical Society.

Physical Review A•Jul 1, 1996•8 citations

Optical spectra of an intracavity two-photon medium with sequeezed inputs

Zhi‐Cheng Wang, Gong Yu, Songyi Zheng +1 more

The European Physical Journal B•Mar 1, 1994•0 citations

Theory of intracavity absorption spectroscopy

W. Brunner, Henryk Paul

Optical and Quantum Electronics•Mar 1, 1978•28 citations
A new competing beam method is proposed for intracavity measurement of weak absorption. In this method two independent lasers with the same active medium are employed. An investigated sample is placed inside the resonator of one of the lasers with a narrow tunable emission line. In contrast to the selective intracavity absorption method, photoelectric recording of the spectra can be used in the proposed method and this can be done for narrow lines as well as for wide absorption bands. Moreover, the new method can be used to determine the two-photon absorption spectra.
To test the application of solid-state lasers to intracavity laser absorption spectroscopy (ICLAS), we studied a neodymium-doped glass laser, in the presence of extreme relaxation oscillations (up to 108{10}^{8}108 intensity contrast). The contrast of these oscillations could be varied by changing the Q-switch transition time. The recorded absorption spectra accurately follow the regular ICLAS behavior except when the intensity in the first relaxation oscillation minimum becomes too low. In such a case, we find that the ICLAS absorption spectrum accumulated during the first spike is ``forgotten'' by the system. Numerical simulations were done which accurately describe the observed transition to a regime of memory loss, when the number of photons circulating in each mode drops close to 1. These simulations show that the mechanism of memory loss is the prevailing of spontaneous over stimulated emission. This effect sets the fundamental limit of the sensitivity of an ICLAS spectrometer where the nonlinear mode interactions are negligible. This effect was observed before only in a diode laser system with high internal losses. In this paper we report an observation of ICLAS sensitivity saturation by spontaneous emission during relaxation oscillations in a laser with low cavity losses. \textcopyright{} 1996 The American Physical Society.