Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Fluxonium qubit readout with the Josephson parametric converter

Michael Hatridge, Baleegh Abdo, Archana Kamal, Nicholas A. Masluk, Flavius Schackert, Michel Devoret

Published Mar 21, 2011• 0 citations
OpenAlex

Related papers

Single-shot readout and state preparation of a fluxonium qubit without the use of a parametric amplifier

Daria Gusenkova, Martin Spiecker, Richard Gebauer +9 more

Bulletin of the American Physical Society•Mar 5, 2020•0 citations

Readout of fluxonium qubits in circuit QED

Konstantin Nesterov, Long B. Nguyen, Aaron Somoroff +7 more

Bulletin of the American Physical Society•Mar 2, 2020•0 citations

Simulation and measurement of a fluxonium qubit inductively coupled to a readout resonator

W. Clarke Smith, Angela Kou, Uri Vool +3 more

Bulletin of the American Physical Society•Mar 6, 2015•0 citations

Observing quantum jumps of a transmon qubit with a Josephson parametric converter

Shyam Shankar, Michael Hatridge, Flavius Schackert +7 more

Bulletin of the American Physical Society•Feb 28, 2012•0 citations

Fluxon readout for superconducting qubits

Kirill G. Fedorov, Anastasia V. Shcherbakova, Alexey Vladimirovich Ustinov

Bulletin of the American Physical Society•Mar 5, 2014•0 citations

High-fidelity QND readout and measurement back-action in a tantalum-based high-coherence fluxonium qubit

Gaurav Bothara, Srijita Das, Kishor V. Salunkhe +4 more

Implementing a precise measurement of the quantum state of a qubit is critical for building a practical quantum processor, as it plays an important role in state initialization and quantum error correction. While the transmon qubit has been the most commonly used design in small- to medium-scale processors, the fluxonium qubit is emerging as a strong alternative with the potential for high-fidelity gate operation as a result of the high anharmonicity and high coherence achievable due to its unique design. Here, we explore the measurement characteristics of a tantalum-based high-coherence fluxonium qubit and demonstrate single-shot measurement fidelity (assignment fidelity) of 96.2% ± 0.5% and 97.8% ± 0.4% without and with the use of a Josephson parametric amplifier, respectively. We study the back-action of the measurement photons on the qubit and measure a QND fidelity of 99.0% ± 0.3%. We find that the measurement fidelity and the QND nature are limited by state-mixing errors, and our results suggest that a careful study of measurement-induced transitions in the fluxonium is needed to further optimize the readout performance.

APL Quantum•Apr 9, 2025•5 citations
Implementing a precise measurement of the quantum state of a qubit is critical for building a practical quantum processor, as it plays an important role in state initialization and quantum error correction. While the transmon qubit has been the most commonly used design in small- to medium-scale processors, the fluxonium qubit is emerging as a strong alternative with the potential for high-fidelity gate operation as a result of the high anharmonicity and high coherence achievable due to its unique design. Here, we explore the measurement characteristics of a tantalum-based high-coherence fluxonium qubit and demonstrate single-shot measurement fidelity (assignment fidelity) of 96.2% ± 0.5% and 97.8% ± 0.4% without and with the use of a Josephson parametric amplifier, respectively. We study the back-action of the measurement photons on the qubit and measure a QND fidelity of 99.0% ± 0.3%. We find that the measurement fidelity and the QND nature are limited by state-mixing errors, and our results suggest that a careful study of measurement-induced transitions in the fluxonium is needed to further optimize the readout performance.