Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Optical pumping-assisted electromagnetically induced transparency (7 pages)

Wei Zhong Jiang, Q.-f. Chen, Y.-s. Zhang

Published Jan 1, 2006• 0 citations
OpenAlex

Related papers

The Defect on Electromagnetically Induced Transparency by Optical Pumping

Chin‐Chun Tsai, Yung-Yung Chang, Zong-Syun He +3 more

Bulletin of the American Physical Society•May 27, 2010•0 citations

Ladder-type Electromagnetically Induced Transparency with Optical Pumping Effect

Zong-Syun He, Chin‐Chun Tsai, Jyh-Hung Tsai +2 more

Bulletin of the American Physical Society•Jun 4, 2013•0 citations

Electromagnetically Induced Transparency and optical pumping processes formed in Cs sub-micron thin cell

Armen D. Sargsyan, Claude Leroy, Y. Pashayan-Leroy +3 more

Optics Communications•Jan 11, 2012•15 citations

Influence on the Optical Pumping Effect to the Susceptibility of the Electromagnetically Induced Transparency Medium

左鹏程 ZUO Peng-cheng, 车少娜 CHE Shao-na, 武晋则 WU Jin-ze +2 more

Acta Sinica Quantum Optica•Jan 1, 2016•0 citations

Tunable frequency reference by optical pumping-assisted intracavity V-type electromagnetically induced transparency

Ying Bo Kang, Yueping Niu, Dijun Chen +3 more

A tunable high resolution frequency reference is constructed using the narrowed cavity-linewidth by the optical pumping-assisted V-type electromagnetically induced transparency (EIT). At room temperature, the optical pumping effect will increase the transparency for the V-type EIT and therefore the cavity-linewidth can be narrowed apparently. For the seven EITs observed in our previous study, cavity-linewidth narrowing is observed in all of them. More importantly, we find that the cavity-linewidth can keep at 1.2MHz in a wide frequency range of 100MHz by utilizing the central EIT. This property provides a novel way for constructing high resolution tunable frequency reference via the intracavity EIT.

arXiv:1309.3336•Sep 12, 2013•3 citations

Experiments in Electromagnetically Induced Transparency

A. Kasapi, G. Y. Yin, Manoj Kumar Jain +2 more

•May 8, 1994•0 citations
A tunable high resolution frequency reference is constructed using the narrowed cavity-linewidth by the optical pumping-assisted V-type electromagnetically induced transparency (EIT). At room temperature, the optical pumping effect will increase the transparency for the V-type EIT and therefore the cavity-linewidth can be narrowed apparently. For the seven EITs observed in our previous study, cavity-linewidth narrowing is observed in all of them. More importantly, we find that the cavity-linewidth can keep at 1.2MHz in a wide frequency range of 100MHz by utilizing the central EIT. This property provides a novel way for constructing high resolution tunable frequency reference via the intracavity EIT.