Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Using a High-Q Josephson Resonator as a Non-Dissipative RF-SQUID

Joshua Strong, Kevin D. Osborn, Adam J. Sirois, Raymond W. Simmonds

Published Mar 9, 2007• 0 citations
OpenAlex

Related papers

Intrinsic flux noise of high-Tc RF-SQUID in the dissipative mode

Xiaohui Wang, Jin Xin, Xixian Yao

Physica C Superconductivity•Oct 1, 1992•1 citation

Macroscopic quantum tunneling and dissipation in Josephson junctions and SQUIDs

K. K. Likharev

Physica B+C•Aug 1, 1981•14 citations

Low-Back-Action RF SQUID Readout for a Josephson Flux Qubit Measurement

V. I. Shnyrkov, Andrii P. Shapovalov, A.A. Kalenyuk +3 more

Superconducting qubits demonstrate good perspectives as scalable blocks for quantum information processing. These systems can be individually readout, addressed, and controlled, making them some of the most attractive thin-film qubits. Quantum measurements should be performed in order to readout the final state of flux qubits. To observe the dynamics of such systems, one requires a fast magnetometer with exceptional sensitivity and low back-action. We address the problem of reducing the back-action of an RF SQUID readout circuit, which may significantly destroy a Josephson flux qubit in the case of the circuits integration. The main sources of such back-action in conventional RF SQUID and DC SQUID circuits are low-ohmic shunting resistors ensuring high damping. The advantage of flux qubits is the presence of an optimal bias point at which, in the first-order approximation, the device is immune to fluctuations in readout and control lines. Nonetheless, even such systems have characteristics limited by a second-order dissipation. The dissipation can be eliminated by using an “ideal parametric readout” based on an RF SQUID acting in non-hysteretic adiabatic mode. In this paper, we propose an RF SQUID in a non-hysteretic regime as a fast, sensitive, and scalable readout system with low back-action for measurements of a single MW photon counter based on a flux qubit.

IEEE International Conference on Electronics and Information Technologies (ELIT)•May 19, 2021•1 citation

High-Tc rf SQUIDs with large inductance of quantization loop

A. V. Sermyagin

arXiv:cond-mat/0305046•Physica C Superconductivity•Nov 7, 2003•0 citations

An RF SQUID readout for a flux qubit-based microwave single photon counter

V. I. Shnyrkov, Andrii P. Shapovalov, V. Yu. Lyakhno +3 more

Abstract An analysis of the measurement of the magnetic flux in superconducting qubits based on RF SQUIDs was carried out with an 800 MHz bandwidth low-power-consumption cryogenic high-electron-mobility transistor amplifier. The preliminary experimental results obtained at temperatures 2 K and 4 K for RF SQUIDs in hysteretic, and in two non-hysteretic, regimes with a pump frequency of about 30 MHz are discussed. Parameters of RF SQUIDs in the hysteretic and non-hysteretic modes are analyzed within the framework of the resistively and capacitively shunted junction model for Josephson junctions. Its sensitivity at a temperature of 30 mK and frequency band (speed) are calculated and optimized to read the states of a flux qubit used as a single microwave photon counter. It is shown that an RF SQUID, operated in an adiabatic non-hysteretic mode for qubit readout, allows us to minimize its back-action effect and the dark count rate. This is due to the absence of Josephson generation, the small amplitude of the resonator electromagnetic field, and the selection of the pump frequency that does not coincide with the characteristic frequencies of the flux qubit.

Superconductor Science and Technology•Jan 6, 2023•10 citations

Resonant frequency of high Tc rf-SQUID resonator

Akira Sakai

The Japan Society of Applied Physics•Jul 4, 2013•0 citations
Superconducting qubits demonstrate good perspectives as scalable blocks for quantum information processing. These systems can be individually readout, addressed, and controlled, making them some of the most attractive thin-film qubits. Quantum measurements should be performed in order to readout the final state of flux qubits. To observe the dynamics of such systems, one requires a fast magnetometer with exceptional sensitivity and low back-action. We address the problem of reducing the back-action of an RF SQUID readout circuit, which may significantly destroy a Josephson flux qubit in the case of the circuits integration. The main sources of such back-action in conventional RF SQUID and DC SQUID circuits are low-ohmic shunting resistors ensuring high damping. The advantage of flux qubits is the presence of an optimal bias point at which, in the first-order approximation, the device is immune to fluctuations in readout and control lines. Nonetheless, even such systems have characteristics limited by a second-order dissipation. The dissipation can be eliminated by using an “ideal parametric readout” based on an RF SQUID acting in non-hysteretic adiabatic mode. In this paper, we propose an RF SQUID in a non-hysteretic regime as a fast, sensitive, and scalable readout system with low back-action for measurements of a single MW photon counter based on a flux qubit.
Abstract An analysis of the measurement of the magnetic flux in superconducting qubits based on RF SQUIDs was carried out with an 800 MHz bandwidth low-power-consumption cryogenic high-electron-mobility transistor amplifier. The preliminary experimental results obtained at temperatures 2 K and 4 K for RF SQUIDs in hysteretic, and in two non-hysteretic, regimes with a pump frequency of about 30 MHz are discussed. Parameters of RF SQUIDs in the hysteretic and non-hysteretic modes are analyzed within the framework of the resistively and capacitively shunted junction model for Josephson junctions. Its sensitivity at a temperature of 30 mK and frequency band (speed) are calculated and optimized to read the states of a flux qubit used as a single microwave photon counter. It is shown that an RF SQUID, operated in an adiabatic non-hysteretic mode for qubit readout, allows us to minimize its back-action effect and the dark count rate. This is due to the absence of Josephson generation, the small amplitude of the resonator electromagnetic field, and the selection of the pump frequency that does not coincide with the characteristic frequencies of the flux qubit.