Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer eBooks

Critical Slowing Down and Magnetically-Induced Self-Pulsing in a Sodium-Filled Fabry-Perot Resonator

J. Mlynek, Fedor M. Mitschke, Wulfhard K. Lange

Published Jan 1, 1984• 0 citations
Publisher
DOI
10.1007/978-1-4684-4718-7_23

Related papers

Nonlinear dynamics of sodium-filled Fabry-Perot resonators (A)

F. T. Arecchi, W. Gadomski, R. Meucci

Journal of the Optical Society of America B•Feb 1, 1986•0 citations

Transmission Properties of a Sodium-Filled Fabry-Perot Resonator

Giovanni Giusfredi, S. Cecchi, E. Petriella +2 more

Springer series in synergetics•Jan 1, 1987•2 citations

Transverse structures in a sodium-filled Fabry-Pérot resonator—I. Experimental results: Symmetries and the role of the incoupling conditions

Gian Luca Lippi, T. Ackemann, Lois M. Hoffer +1 more

Chaos Solitons & Fractals•Aug 1, 1994•13 citations

Self-induced light trapping in nonlinear Fabry–Perot resonators

K. N. Pichugin, Almas F. Sadreev

Physics Letters A•Sep 2, 2016•7 citations

Multistability in a sodium filled Fabry-Perot: D1 line, hyperfine and Zeeman pumping

Giovanni Giusfredi, P. Salieri, S. Cecchi +1 more

Optics Communications•May 1, 1985•24 citations

Critical Slowing Down and Magnetically-Induced Self-Pulsing in a Sodium-Filled Fabry-Perot Resonator

J. Mlynek, Fedor M. Mitschke, Wulfhard K. Lange

We report on the observation of critical slowing down and of self-pulsing in a Fabry-Perot resonator (FP) filled with sodium atoms under conditions of transverse optical pumping /1/. The experimental set-up (see Fig.1) is similar to the one used in steady-state bistability studies reported before /2/. The dye laser, optically isolated from the FP by means of a Faraday rotator (FR) is detuned from the Na D1-line by 10 to 20 GHz. The sodium sample (N ≃ 1013 cm–3, buffer gas: argon, p=200 mbar) is placed in a near confocal Fabry-Perot (Beam waist: 1 20 μm) and can be subjected to a transverse magnetic field B. The intensity of the laser beam can be switched by means of an electro-optic modulator(EOM), thus providing input-steps of variable height (power:5 – 50 mW). A polarizer P1 is used to either circularly or linearly polarize the input beam. The right– and left circular polarization components of the resonator output beam can be separated by means of a λ/4-plate and a polarizing beam splitter P2. A pair of photodiodes PDi is used for detection.

Topical Meeting on Optical Bistability (OB)•Jan 1, 1983•0 citations
We report on the observation of critical slowing down and of self-pulsing in a Fabry-Perot resonator (FP) filled with sodium atoms under conditions of transverse optical pumping /1/. The experimental set-up (see Fig.1) is similar to the one used in steady-state bistability studies reported before /2/. The dye laser, optically isolated from the FP by means of a Faraday rotator (FR) is detuned from the Na D1-line by 10 to 20 GHz. The sodium sample (N ≃ 1013 cm–3, buffer gas: argon, p=200 mbar) is placed in a near confocal Fabry-Perot (Beam waist: 1 20 μm) and can be subjected to a transverse magnetic field B. The intensity of the laser beam can be switched by means of an electro-optic modulator(EOM), thus providing input-steps of variable height (power:5 – 50 mW). A polarizer P1 is used to either circularly or linearly polarize the input beam. The right– and left circular polarization components of the resonator output beam can be separated by means of a λ/4-plate and a polarizing beam splitter P2. A pair of photodiodes PDi is used for detection.