Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics Letters

Measurement of Secular Motion Frequency in Miniature Paul Trap to Ascertain the Stability Parameters

郭彬, 管桦, 刘曲, 黄垚, 黄学人, 高克林

Published Jan 1, 2010• 0 citations
OpenAlex

Abstract

40Ca+ 离子在一个缩小的保罗陷井被套住,激光冷却了。世俗的运动被离子云的无线电频率回声和一个单个离子的 Zeeman 侧面边带试验性地观察。陷井稳定性参数 and q 被世俗的运动频率测量在 1 % 下面与无常决定。陷井效率是 0.75。一个适用的建议为一个新陷井图案的好处被给。[从作者抽象]

Related papers

Measurement of Secular Motion Frequency in Miniature Paul Trap to Ascertain the Stability Parameters

Bin Guo, Guan Hua, Liu Qu +3 more

40 Ca + ions are trapped and laser cooled in a miniature Paul trap. The secular motion was observed by the radio-frequency resonance of the ion cloud and Zeeman profile sidebands of a single ion experimentally. The trap stability parameters a and q are determined with an uncertainty under 1 % by the secular motion frequency measurement. The trap efficiency is 0.75. A practicable suggestion is given for the benefits of a new trap design.

Chinese Physics Letters•Jan 1, 2010•4 citations

Controlling the rf phase error induced micromotion in Paul trap

Ting Chen, Wei Wu, Yi Xie +4 more

Applied Physics B•May 15, 2020•2 citations

Systematic studies of ion motion in a Paul trap by means of self-induced coherences

H. Ebensing, Alex Newburgh, H. Harde

Using a newly developed technique that takes advantage of self-induced Zeeman coherences,1 we have studied the motion of stored ions in a Paul trap. We demonstrate the potential for measuring the complete spectrum of the ion oscillations consisting of the macro- and micromotion. The influence of the storage parameters and the ion density on the secular frequency is investigated with high spectral resolution.

Quantum Electronics and Laser Science Conference•May 2, 1993•0 citations

The linear Paul Trap's Confined Stability Area for 40Ca+ Ions

Basem R. Kazem, Mezher B. Saleh

تقدم تكنولوجيا الكم طرقًا حسابية واتصالات ومحاكاة وقياسًا جديدة. تحتاج أجهزة الكمبيوتر التقليدية إلى المساعدة في حل المشكلات المهمة مثل التحليل بسبب الزيادات الهائلة في وقت الحساب. ومع ذلك، تستخدم أجهزة الكمبيوتر الكمومية ميكانيكا الكم لحجم المشكلة الأسي الفرعي ويمكنها محاكاة الطبيعة على المستوى الكمي. يهتم العلماء بشكل متزايد بتطوير أجهزة الكمبيوتر الكمومية باستخدام ذرات متأينة مفردة في مصائد باولي. تمثل الحالة الأساسية لكل أيون أقل قيمة ممكنة للبت الكمي. تم استخدام الأيونات المحتجزة 40Ca+ في إحدى الدراسات كمثال على الكيوبت الكمومي. تم استخدام برنامج MATLAB على العوامل النموذجية التي تؤثر على الحالة المقيدة وتأثيراتها. يجب أن تكون الحلول مستقرة في كلا الاتجاهين، مما يتطلب حصرًا ثلاثي الأبعاد لمعادلة ماثيو. تؤثر المتغيرات على المسافة من مركز المصيدة لنهاية القطب، وجهد UDC، وكتلة الأيون، والترددات الراديوية. تم استخدام جهد متغير للتحكم وإظهار تأثيره على سلسلة محددة من الأيونات المحاصرة. يهدف هذا البحث إلى فهم أفضل للظروف المثلى للحجز وحركة الأيونات من الحالة (4S1/2) إلى الحالة (4P1/2) بالرنين. تخضع الحالة الكمومية للتعديل والتغيير، مما يجعلها أداة واعدة لحل المشكلات المعقدة.

journal of the college of basic education•Feb 1, 2024•0 citations

Measurement of the oscillator strength of the E2 transition Cs(6S-5D)

Wallace L. Glab, Munir Hasan Nayfeh

Optics Communications•Aug 1, 1981•6 citations

Secular Motion Frequencies of 9Be+ Ions and 40Ca+ Ions in Bi-component Coulomb Crystals*

Haixia Li, Min Li, Qian-Yu Zhang +1 more

We obtain bi-component Coulomb crystals using laser-cooled 40Ca+ ions to sympathetically cool 9Be+ ions in a linear Paul trap. The shell structures of the bi-component Coulomb crystals are investigated. The secular motion frequencies of the two different ions are determined and compared with those in the single-component Coulomb crystals. In the radial direction, the resonant motion frequencies of the two ionic species shift toward each other due to the strong motion coupling in the ion trap. In the axial direction, the motion frequency of the laser-cooled 40Ca+ is impervious to the sympathetically cooled 9Be+ ions because the spatially separation of the two different ionic species leads to the weak motion coupling in the axial direction.

Chinese Physics Letters•Jul 1, 2019•10 citations
40Ca+ 离子在一个缩小的保罗陷井被套住,激光冷却了。世俗的运动被离子云的无线电频率回声和一个单个离子的 Zeeman 侧面边带试验性地观察。陷井稳定性参数 and q 被世俗的运动频率测量在 1 % 下面与无常决定。陷井效率是 0.75。一个适用的建议为一个新陷井图案的好处被给。[从作者抽象]
تقدم تكنولوجيا الكم طرقًا حسابية واتصالات ومحاكاة وقياسًا جديدة. تحتاج أجهزة الكمبيوتر التقليدية إلى المساعدة في حل المشكلات المهمة مثل التحليل بسبب الزيادات الهائلة في وقت الحساب. ومع ذلك، تستخدم أجهزة الكمبيوتر الكمومية ميكانيكا الكم لحجم المشكلة الأسي الفرعي ويمكنها محاكاة الطبيعة على المستوى الكمي. يهتم العلماء بشكل متزايد بتطوير أجهزة الكمبيوتر الكمومية باستخدام ذرات متأينة مفردة في مصائد باولي. تمثل الحالة الأساسية لكل أيون أقل قيمة ممكنة للبت الكمي. تم استخدام الأيونات المحتجزة 40Ca+ في إحدى الدراسات كمثال على الكيوبت الكمومي. تم استخدام برنامج MATLAB على العوامل النموذجية التي تؤثر على الحالة المقيدة وتأثيراتها. يجب أن تكون الحلول مستقرة في كلا الاتجاهين، مما يتطلب حصرًا ثلاثي الأبعاد لمعادلة ماثيو. تؤثر المتغيرات على المسافة من مركز المصيدة لنهاية القطب، وجهد UDC، وكتلة الأيون، والترددات الراديوية. تم استخدام جهد متغير للتحكم وإظهار تأثيره على سلسلة محددة من الأيونات المحاصرة. يهدف هذا البحث إلى فهم أفضل للظروف المثلى للحجز وحركة الأيونات من الحالة (4S1/2) إلى الحالة (4P1/2) بالرنين. تخضع الحالة الكمومية للتعديل والتغيير، مما يجعلها أداة واعدة لحل المشكلات المعقدة.
We obtain bi-component Coulomb crystals using laser-cooled 40Ca+ ions to sympathetically cool 9Be+ ions in a linear Paul trap. The shell structures of the bi-component Coulomb crystals are investigated. The secular motion frequencies of the two different ions are determined and compared with those in the single-component Coulomb crystals. In the radial direction, the resonant motion frequencies of the two ionic species shift toward each other due to the strong motion coupling in the ion trap. In the axial direction, the motion frequency of the laser-cooled 40Ca+ is impervious to the sympathetically cooled 9Be+ ions because the spatially separation of the two different ionic species leads to the weak motion coupling in the axial direction.