Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Focal Plane Arrays of Voltage-Biased Superconducting Bolometers

Michael J. Myers, John Clarke, Jan M. Gildemeister, Adrian Tae-Jin Lee, P. L. Richards, Dan Schwan, J. T. Skidmore, H. G. Spieler, Jongsoo Yoon

Published Dec 1, 2001• 0 citations
OpenAlex

Abstract

The 200-micrometer to 3-mm wavelength range has great astronomical and cosmological significance. Science goals include characterization of the cosmic microwave background, measurement of the Sunyaev-Zel'dovich effect in galaxy clusters, and observations of forming galaxies. Cryogenic bolometers are the most sensitive broadband detectors in this frequency range. Because single bolometer pixels are reaching the photon noise limit for many observations, the development of large arrays will be critical for future science progress. Voltage-biased superconducting bolometers (VSBs) have several advantages compared to other cryogenic bolometers. Their strong negative electrothermal feedback enhances their linearity, speed, and stability. The large noise margin of the SQUID readout enables multiplexed readout schemes, which are necessary for developing large arrays. In this paper, we discuss the development of a large absorber-coupled array, a frequency-domain SQUID readout multiplexer, and an antenna-coupled VSB design.

Related papers

Antenna-coupled arrays of voltage-biased superconducting bolometers

Michael J. Myers, Adrian Tae-Jin Lee, P. L. Richards +5 more

We report on the development of antenna-coupled Voltage-biased Superconducting Bolometers (VSBs) which use Transition-edge Sensors (TES). Antenna coupling can greatly simplify the fabrication of large multi-frequency bolometer arrays compared to horn-coupled techniques. This simplification can make it practical to implement 1000+ element arrays that fill the focal plane of mm/sub-mm wave telescopes. We have designed a prototype device with a double-slot dipole antenna, integrated band-defining filters, and a membrane-suspended bolometer. A test chip has been constructed and will be tested shortly.

Lawrence Berkeley National Laboratory•Jul 23, 2001•2 citations

New technologies for the detection of millimeter and submillimeter waves

P. L. Richards

Voltage-biased superconducting bolometers have many operational advantages over conventional bolometer technology including sensitivity, linearity, speed, and immunity from environmental disturbance.A review is given of the Berkeley program for developing this new technology.Developments include fully lithographed individual bolometers in the spiderweb configuration, arrays of 1024 close-packed absorber-coupled bolometers, antenna-coupled bolometers, and a frequency-domain SQUID readout multiplexer.

AIP conference proceedings•Jan 1, 2002•2 citations

Single SQUID multiplexer for arrays of voltage-biased superconducting bolometers

Jongsoo Yoon, John L. Clarke, Jan M. Gildemeister +5 more

We describe a frequency domain superconducting quantum interference device (SQUID) multiplexer which monitors a row of low-temperature sensors simultaneously with a single SQUID. Each sensor is ac biased with a unique frequency and all the sensor currents are added in a superconducting summing loop. A single SQUID measures the current in the summing loop, and the individual signals are lock-in detected after the room temperature SQUID electronics. The current in the summing loop is nulled by feedback to eliminate direct crosstalk. In order to avoid the accumulation of Johnson noise in the summing loop, a tuned bandpass filter is inserted in series with each sensor. For a 32-channel multiplexer for Voltage-biased Superconducting Bolometer (VSB) with a time constant {approx}1msec, we estimate that bias frequencies in the range from {approx}500kHz to {approx}600kHz are practical. The major limitation of our multiplexing scheme is in the slew rate of a readout SQUID. We discuss a ''carrier nulling'' technique which could be used to increase the number of sensors in a row or to multiplex faster bolometers by reducing the required slew rate for a readout SQUID.

Lawrence Berkeley National Laboratory•Aug 20, 2001•0 citations

Single SQUID multiplexer for arrays of Voltage-biased Superconducting Bolometers

Jongsoo Yoon, John L. Clarke, Jan M. Gildemeister +5 more

We describe a frequency domain superconducting quantum interference device (SQUID) multiplexer which monitors a row of low-temperature sensors simultaneously with a single SQUID. Each sensor is ac biased with a unique frequency and all the sensor currents are added in a superconducting summing loop. A single SQUID measures the current in the summing loop, and the individual signals are lock-in detected after the room temperature SQUID electronics. The current in the summing loop is nulled by feedback to eliminate direct crosstalk. In order to avoid the accumulation of Johnson noise in the summing loop, a tuned bandpass filter is inserted in series with each sensor. To multiplex 32 Voltage-biased Superconducting Bolometers (VSB) with 1 msec time constants a total bandwidth of 100 kHz is required. The minimum bias frequency is limited to ≳500 kHz by practical limitations in the size of photolithographed inductors and capacitors. The major limitation of our multiplexing scheme is in the slew rate of the readout SQUID. We discuss a “carrier nulling” technique which could be used to increase the number of sensors in a row or to multiplex faster bolometers by reducing the required slew rate for a readout SQUID.

AIP conference proceedings•Jan 1, 2002•3 citations

A fully lithographed voltage-biased superconducting spiderweb bolometer

Jan M. Gildemeister, Adrian Tae-Jin Lee, P. L. Richards

We describe the fabrication and characterization of superconducting transition-edge bolometers for astrophysical applications at far-infrared and mm wavelengths. The sensor is voltage biased and the current is measured with a superconducting quantum interference ammeter. Strong negative electrothermal feedback keeps the sensor temperature nearly constant, reduces the response time significantly, and improves linearity. It also makes the responsivity relatively insensitive to changes in optical background loading and refrigerator temperature. The bolometers are made using standard microlithographic techniques suitable for fabrication of large scale arrays. Detailed measurements of optical response are presented for a range of bias conditions and are compared with theory. Measured noise spectra are shown and a model for the noise is presented.

Applied Physics Letters•Feb 8, 1999•88 citations

Readout demonstration of 512 TES bolometers using a single microwave SQUID multiplexer (Conference Presentation)

Bradley Dober, Zeeshan Ahmed, Jason E. Austermann +30 more

To enable the next-generation of bolometric cameras, we are developing the microwave SQUID multiplexer (μMUX). Upcoming receivers such as Simons Observatory, CCAT-prime, BICEP array, Ali-CPT, and CMB-S4 plan to instrument focal planes with 50,000-500,000 sensors. Sensor count is achieved by tiling many 150 mm-diameter densely packed detector arrays into these focal planes. The fabrication and quality of large-format bolometer arrays has been demonstrated and is now mature. In contrast, the readout technology required for next-generation receivers needs development. The sensitivity, low cross-talk, high multiplexing density, and small component size make the μMUX well-suited for this goal. In this approach, the TES signal modulates the inductance of an rf-SQUID that loads a high-Q microwave resonator. The coupled signal therefore modulates the microwave resonance frequency, which may be read out using homodyne techniques. By coupling each resonator to the same microwave feedline, many detectors can be read out on a single coaxial cable pair. The multiplexing density is in practice limited by signal bandwidth, allowable cross-talk, and the digitization bandwidth of room-temperature readout electronics. We present the design and performance of a scalable 64-channel multiplexer chip optimized for bolometric applications. We utilize a new quarter wave resonator design that increases the physical linear density by a factor of two, therefore achieving a smaller footprint for simplified detector packaging. Measurements of this design show 100 kHz resonator bandwidth, uniform 1.8 MHz frequency spacing, and an input referred current noise of 35 pA/√Hz that is well below the level of an optimized, background-limited TES bolometer. Using 8 daisy-chained and frequency scaled chips, we create a 512-channel multiplexer and use it to readout a 512 TES-bolometer array. We present the results of this large-scale μMUX demonstration including system yield, signal cross-talk, and an analysis of noise in various TES bias configurations. The result demonstrates the multiplexing density required to read out 2,000 sensors between 4-8 GHz.

Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy XI•Jul 10, 2018•1 citation
The 200-micrometer to 3-mm wavelength range has great astronomical and cosmological significance. Science goals include characterization of the cosmic microwave background, measurement of the Sunyaev-Zel'dovich effect in galaxy clusters, and observations of forming galaxies. Cryogenic bolometers are the most sensitive broadband detectors in this frequency range. Because single bolometer pixels are reaching the photon noise limit for many observations, the development of large arrays will be critical for future science progress. Voltage-biased superconducting bolometers (VSBs) have several advantages compared to other cryogenic bolometers. Their strong negative electrothermal feedback enhances their linearity, speed, and stability. The large noise margin of the SQUID readout enables multiplexed readout schemes, which are necessary for developing large arrays. In this paper, we discuss the development of a large absorber-coupled array, a frequency-domain SQUID readout multiplexer, and an antenna-coupled VSB design.
We report on the development of antenna-coupled Voltage-biased Superconducting Bolometers (VSBs) which use Transition-edge Sensors (TES). Antenna coupling can greatly simplify the fabrication of large multi-frequency bolometer arrays compared to horn-coupled techniques. This simplification can make it practical to implement 1000+ element arrays that fill the focal plane of mm/sub-mm wave telescopes. We have designed a prototype device with a double-slot dipole antenna, integrated band-defining filters, and a membrane-suspended bolometer. A test chip has been constructed and will be tested shortly.
Voltage-biased superconducting bolometers have many operational advantages over conventional bolometer technology including sensitivity, linearity, speed, and immunity from environmental disturbance.A review is given of the Berkeley program for developing this new technology.Developments include fully lithographed individual bolometers in the spiderweb configuration, arrays of 1024 close-packed absorber-coupled bolometers, antenna-coupled bolometers, and a frequency-domain SQUID readout multiplexer.
We describe a frequency domain superconducting quantum interference device (SQUID) multiplexer which monitors a row of low-temperature sensors simultaneously with a single SQUID. Each sensor is ac biased with a unique frequency and all the sensor currents are added in a superconducting summing loop. A single SQUID measures the current in the summing loop, and the individual signals are lock-in detected after the room temperature SQUID electronics. The current in the summing loop is nulled by feedback to eliminate direct crosstalk. In order to avoid the accumulation of Johnson noise in the summing loop, a tuned bandpass filter is inserted in series with each sensor. For a 32-channel multiplexer for Voltage-biased Superconducting Bolometer (VSB) with a time constant {approx}1msec, we estimate that bias frequencies in the range from {approx}500kHz to {approx}600kHz are practical. The major limitation of our multiplexing scheme is in the slew rate of a readout SQUID. We discuss a ''carrier nulling'' technique which could be used to increase the number of sensors in a row or to multiplex faster bolometers by reducing the required slew rate for a readout SQUID.
We describe a frequency domain superconducting quantum interference device (SQUID) multiplexer which monitors a row of low-temperature sensors simultaneously with a single SQUID. Each sensor is ac biased with a unique frequency and all the sensor currents are added in a superconducting summing loop. A single SQUID measures the current in the summing loop, and the individual signals are lock-in detected after the room temperature SQUID electronics. The current in the summing loop is nulled by feedback to eliminate direct crosstalk. In order to avoid the accumulation of Johnson noise in the summing loop, a tuned bandpass filter is inserted in series with each sensor. To multiplex 32 Voltage-biased Superconducting Bolometers (VSB) with 1 msec time constants a total bandwidth of 100 kHz is required. The minimum bias frequency is limited to ≳500 kHz by practical limitations in the size of photolithographed inductors and capacitors. The major limitation of our multiplexing scheme is in the slew rate of the readout SQUID. We discuss a “carrier nulling” technique which could be used to increase the number of sensors in a row or to multiplex faster bolometers by reducing the required slew rate for a readout SQUID.
We describe the fabrication and characterization of superconducting transition-edge bolometers for astrophysical applications at far-infrared and mm wavelengths. The sensor is voltage biased and the current is measured with a superconducting quantum interference ammeter. Strong negative electrothermal feedback keeps the sensor temperature nearly constant, reduces the response time significantly, and improves linearity. It also makes the responsivity relatively insensitive to changes in optical background loading and refrigerator temperature. The bolometers are made using standard microlithographic techniques suitable for fabrication of large scale arrays. Detailed measurements of optical response are presented for a range of bias conditions and are compared with theory. Measured noise spectra are shown and a model for the noise is presented.
To enable the next-generation of bolometric cameras, we are developing the microwave SQUID multiplexer (μMUX). Upcoming receivers such as Simons Observatory, CCAT-prime, BICEP array, Ali-CPT, and CMB-S4 plan to instrument focal planes with 50,000-500,000 sensors. Sensor count is achieved by tiling many 150 mm-diameter densely packed detector arrays into these focal planes. The fabrication and quality of large-format bolometer arrays has been demonstrated and is now mature. In contrast, the readout technology required for next-generation receivers needs development. The sensitivity, low cross-talk, high multiplexing density, and small component size make the μMUX well-suited for this goal. In this approach, the TES signal modulates the inductance of an rf-SQUID that loads a high-Q microwave resonator. The coupled signal therefore modulates the microwave resonance frequency, which may be read out using homodyne techniques. By coupling each resonator to the same microwave feedline, many detectors can be read out on a single coaxial cable pair. The multiplexing density is in practice limited by signal bandwidth, allowable cross-talk, and the digitization bandwidth of room-temperature readout electronics. We present the design and performance of a scalable 64-channel multiplexer chip optimized for bolometric applications. We utilize a new quarter wave resonator design that increases the physical linear density by a factor of two, therefore achieving a smaller footprint for simplified detector packaging. Measurements of this design show 100 kHz resonator bandwidth, uniform 1.8 MHz frequency spacing, and an input referred current noise of 35 pA/√Hz that is well below the level of an optimized, background-limited TES bolometer. Using 8 daisy-chained and frequency scaled chips, we create a 512-channel multiplexer and use it to readout a 512 TES-bolometer array. We present the results of this large-scale μMUX demonstration including system yield, signal cross-talk, and an analysis of noise in various TES bias configurations. The result demonstrates the multiplexing density required to read out 2,000 sensors between 4-8 GHz.