Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

European Quantum Electronics Conference (EQEC)

A New Kind Of Magnetic Microtraps For Neutral Atoms

Jakob Reichel, W. Hänsel, C. Sartena, Theodor W. Hänsch

Published Aug 24, 2005• 0 citations
Publisher
DOI
10.1109/eqec.1998.714696

Related papers

Microtraps for neutral atoms

Thomas Lindvall, Anu Huttunen, M. Rodriquez +4 more

•Jan 1, 2001•0 citations

A lattice of permanent magnetic microtraps for ultracold atoms

Mandip Singh, A. M. Akulshin, Andrei I. Sidorov +2 more

Bulletin of the American Physical Society•May 29, 2008•1 citation

Magnetic Microtrap Array of Ultracold Atoms

Bin Jian, William Arie van Wijngaarden

Bulletin of the American Physical Society•Jun 5, 2014•0 citations

Selected aspects of the quantum dynamics and electronic structure of atoms in magnetic microtraps

Igor Lesanovsky, Peter Schmelcher

The European Physical Journal D•May 2, 2005•4 citations

Magnetic-film atom chip setup with 10 $\mu$m period lattices of magnetic microtraps

Vanessa Y. F. Leung, D. R. M. Pijn, Hugo Schlatter +11 more

•Nov 18, 2013•0 citations

Double-Loop Microtrap Array for Ultracold Atoms

Bin Jian

A novel kind of magnetic microtrap is demonstrated for ultracold neutral atoms. It consists of two concentric loops of radii $r_1$ and $r_2$ having oppositely oriented currents. A magnetic field minimum is generated in three dimensions that can be used to trap the atoms with a trap depth of about 1 mK using a current of 2.6 A. The condition $r_2/r_1$ = 2.2 maximizes the restoring force on the atoms toward the trap center. Unlike conventional magnetic microtraps, an external bias field is not required. Moreover, a one dimensional array of double-loop microtraps can be created by daisy chaining single microtrap circuits. \nA linear array of three microtraps having $r_1$ = 300 $\\mu$m was fabricated as part of an atom chip. The following three techniques were developed to load the microtrap array: 1) atoms initially contained in a magneto-optical trap (MOT) were transported to the atom chip by a conventional magnetic trap, 2) atoms were first loaded into a mirror MOT and 3) atoms were initially loaded in a far off resonance optical dipole trap (FORT). Each technique loaded greater than $10^5$ $^{87}$Rb atoms into the microtrap array. The lowest temperature of 30 $\\mu$K for the microtrapped atom cloud was achieved using FORT loading. The strength and the position of the microtrap could be precisely adjusted over a range from 300 to 50 $\\mu$m above the atom chip surface by applying an external bias magnetic field. The lifetime of the atoms trapped in the microtrap array was measured to be 350 ms which was limited by the collisions with residual background gas.

•May 6, 2014•0 citations
Magnetic-film atom chip setup with 10 μ\muμm period lattices of magnetic microtraps
A novel kind of magnetic microtrap is demonstrated for ultracold neutral atoms. It consists of two concentric loops of radii r1r_1r1​ and r2r_2r2​ having oppositely oriented currents. A magnetic field minimum is generated in three dimensions that can be used to trap the atoms with a trap depth of about 1 mK using a current of 2.6 A. The condition r2/r1r_2/r_1r2​/r1​ = 2.2 maximizes the restoring force on the atoms toward the trap center. Unlike conventional magnetic microtraps, an external bias field is not required. Moreover, a one dimensional array of double-loop microtraps can be created by daisy chaining single microtrap circuits. \nA linear array of three microtraps having r1r_1r1​ = 300 mu\\mumum was fabricated as part of an atom chip. The following three techniques were developed to load the microtrap array: 1) atoms initially contained in a magneto-optical trap (MOT) were transported to the atom chip by a conventional magnetic trap, 2) atoms were first loaded into a mirror MOT and 3) atoms were initially loaded in a far off resonance optical dipole trap (FORT). Each technique loaded greater than 10510^5105 87^{87}87Rb atoms into the microtrap array. The lowest temperature of 30 mu\\mumuK for the microtrapped atom cloud was achieved using FORT loading. The strength and the position of the microtrap could be precisely adjusted over a range from 300 to 50 mu\\mumum above the atom chip surface by applying an external bias magnetic field. The lifetime of the atoms trapped in the microtrap array was measured to be 350 ms which was limited by the collisions with residual background gas.