Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

InTech eBooks

Fundamentals and Applications of Quantum Limited Optical Imaging

Warwick P. Bowen, Magnus T. L. Hsu, Jian Wei

Published Apr 1, 2010• 0 citations
Publisher

Abstract

Advances in Lasers and Electro Optics 634 how the QNL to measurement sensitivity may be determined and even surpassed using non-classical states of light.We illustrate the implications of these techniques for two key imaging systems, atomic force microscopy (Binning et al., 1985;Fabre et al., 2000) and particle tracking in optical tweezers (Block, 1992;Tay et al., 2009); comparing optimal spatial homodyne based signal extraction to the standard extraction methods used in such systems today.

DOI
10.5772/8674

Related papers

What is the optimum way to extract information from optical images at the standard quantum limit and beyond ?

Claude Fabre, Nicolas Treps, V. Delaubert +2 more

The problem of extracting a given piece of information from an image with the maximum sensitivity is solved in the general case. Implementations using image intensity processing techniques and homodyne measurements are given.

Conference on Lasers and Electro-Optics•Jan 1, 2006•0 citations

Quantum measurement of biology

Michael A. Taylor

This thesis reports the development of a quantum enhanced microparticle tracking technique, which applied to measurements within living cells, allowed the first demonstrations of both biological measurements beyond the quantum noise limit and quantum enhanced spatial resolution within biology. The sensitivity of any optical measurement is limited by noise which follows from quantization of the electromagnetic field. This thesis theoretically characterizes the resulting quantum limit on particle tracking precision; both in the limit of perfect measurements and for the measurements used in real experiments, and theoretically establishes an experimental strategy which could allow the quantum limit to be surpassed via the application of non-classical light. Further, a computational tool is developed which allows rapid characterization of particle tracking experiments, thus providing researchers the benefit of rigorous theoretical predictions without requiring detailed calculations. Following this, classical technologies are developed which can improve microparticle tracking sensitivity and which are enabling steps toward integration of non-classical light. An interferometric strategy is described whereby signal-to-noise is improved by removing unwanted light from the detector. An optical lock-in technique is developed which eliminates low-frequency noise, thus allowing quantum noise limited performance at low frequencies. This is a crucial requirement for quantum enhanced measurements, and can also improve precision in classical experiments. Dark-field illumination is also explored as a method to remove unwanted background light, and the optimal illumination angle is calculated for our intended experiments. These advances are then applied in the development of the first quantum enhanced particle tracking apparatus. Squeezed states of light are used to improve particle tracking precision by 2.7 dB, demonstrating quantum enhanced microscopy for the first time. This was applied to perform the first measurements of living systems with quantum enhanced precision. Naturally occurring lipid particles were tracked within the cytoplasm of Saccharomyces cerevisiae yeast cells, with squeezed light enhancing precision by 2.4 dB. The thermal motion of these particles could then be analyzed to infer the viscosity and elasticity of the local environment, with squeezed light allowing 64% faster observations, thus improving the sensitivity to dynamic biological changes. This experiment was then extended to spatially resolved quantum imaging, with lipid particles used as scanning probes in a technique called photonic force microscopy. The particles sample variations in the local environment with resolution limited by measurement precision rather than the diffraction limit. The use of squeezed light was found to enhance spatial resolution by 14% at an absolute resolution level of 10 nm, comparable to leading classical experiments. This was the first demonstration of both sub-diffraction limited resolution and quantum enhanced resolution in biology, and places practical applications of quantum imaging within reach. Finally, the future challenges and prospects of quantum enhanced particle tracking are outlined.n

•Jan 1, 2014•0 citations

Ultrasensitive measurement of microcantilever displacement below the shot-noise limit

Raphael C. Pooser, Benjamin J. Lawrie

The displacement of micro-electro-mechanical-systems (MEMS) cantilevers is used to measure a broad variety of phenomena in devices ranging from force microscopes to biochemical sensors to thermal imaging systems. We demonstrate the first direct measurement of a MEMS cantilever displacement with a noise floor at 40% of the shot noise limit (SNL). By combining multi-spatial-mode quantum light sources with a simple differential measurement, we show that sub-SNL MEMS displacement sensitivity is highly accessible compared to previous efforts that measured the displacement of macroscopic mirrors with very distinct spatial structures crafted with multiple optical parametric amplifiers and locking loops. These results support a new class of quantum MEMS sensor with an ultimate signal to noise ratio determined by quantum correlations, enabling ultra-trace sensing, imaging, and microscopy applications in which signals were previously obscured by shot noise.

arXiv:1405.4767•Optica•Apr 23, 2015•214 citations

Quantum Plasmonic Sensing Beyond the Classical Limit

Mohammadjavad Dowran

The ultimate sensitivity of any optically based measurement using classical resources (for example, laser or thermal light) is constrained by the photon shot noise limit (SNL). However, quantum states of light, in which photon pairs have quantum correlations or entanglement, off er a path beyond this limit. In particular, “squeezing” in these quantum states makes it possible to lower the noise in the detection system below the SNL. This can signifi cantly enhance the sensitivity of real-world devices and could thus revolutionize optical-based sensing applications

•Jan 24, 2020•0 citations

Quantum Enhanced Optical Measurements: From Ultra-High Sensitivity in Absorption Measurements to Ghost Microscopy

Elena Losero, Ivano Ruo Berchera, Alessio Avella +2 more

Quantum enhanced optical measurement protocols aim at reducing the uncertainty in the estimation of some physical quantities of a system below the shot-noise limit, classically unavoidable. In particular when small number of photons is used the shot noise can be the main source of uncertainty, in these cases the use of quantum light is of great interest. Note that there are several situations where the number of photons in the probe can not be increased arbitrarily, as when fragile biological samples are under investigation. Two different imaging protocols are discussed in the following.

Italian Quantum Information Science Conference (IQIS)•Jul 25, 2019•0 citations

Phase tracking for sub-shot-noise-limited receivers

M. T. DiMario, F. E. Becerra

Non-conventional receivers for phase-coherent states based on non-Gaussian measurements such as photon counting surpass the sensitivity limits of shot-noise-limited coherent receivers, the quantum noise limit (QNL). These non-Gaussian receivers can have a significant impact in future coherent communication technologies. However, random phase changes in realistic communication channels, such as optical fibers, present serious challenges for extracting the information encoded in coherent states. While there are methods for correcting random phase noise with conventional heterodyne detection, phase-tracking for non-Gaussian receivers surpassing the QNL is still an open problem. Here we demonstrate phase tracking for non-Gaussian receivers to correct for time-varying phase noise while allowing for decoding beyond the QNL. The phase-tracking method performs real-time parameter estimation and correction of phase drifts using the data from the non-Gaussian discrimination measurement, without relying on phase reference pilot fields. This method enables non-Gaussian receivers to achieve higher sensitivities and rates of information transfer than ideal coherent receivers in realistic channels with time-varying phase noise. This demonstration makes sub-QNL receivers a more robust, feasible, and practical quantum technology for classical and quantum communications.

arXiv:2007.02796•Physical Review Research•Jun 23, 2020•15 citations
Advances in Lasers and Electro Optics 634 how the QNL to measurement sensitivity may be determined and even surpassed using non-classical states of light.We illustrate the implications of these techniques for two key imaging systems, atomic force microscopy (Binning et al., 1985;Fabre et al., 2000) and particle tracking in optical tweezers (Block, 1992;Tay et al., 2009); comparing optimal spatial homodyne based signal extraction to the standard extraction methods used in such systems today.
This thesis reports the development of a quantum enhanced microparticle tracking technique, which applied to measurements within living cells, allowed the first demonstrations of both biological measurements beyond the quantum noise limit and quantum enhanced spatial resolution within biology. The sensitivity of any optical measurement is limited by noise which follows from quantization of the electromagnetic field. This thesis theoretically characterizes the resulting quantum limit on particle tracking precision; both in the limit of perfect measurements and for the measurements used in real experiments, and theoretically establishes an experimental strategy which could allow the quantum limit to be surpassed via the application of non-classical light. Further, a computational tool is developed which allows rapid characterization of particle tracking experiments, thus providing researchers the benefit of rigorous theoretical predictions without requiring detailed calculations. Following this, classical technologies are developed which can improve microparticle tracking sensitivity and which are enabling steps toward integration of non-classical light. An interferometric strategy is described whereby signal-to-noise is improved by removing unwanted light from the detector. An optical lock-in technique is developed which eliminates low-frequency noise, thus allowing quantum noise limited performance at low frequencies. This is a crucial requirement for quantum enhanced measurements, and can also improve precision in classical experiments. Dark-field illumination is also explored as a method to remove unwanted background light, and the optimal illumination angle is calculated for our intended experiments. These advances are then applied in the development of the first quantum enhanced particle tracking apparatus. Squeezed states of light are used to improve particle tracking precision by 2.7 dB, demonstrating quantum enhanced microscopy for the first time. This was applied to perform the first measurements of living systems with quantum enhanced precision. Naturally occurring lipid particles were tracked within the cytoplasm of Saccharomyces cerevisiae yeast cells, with squeezed light enhancing precision by 2.4 dB. The thermal motion of these particles could then be analyzed to infer the viscosity and elasticity of the local environment, with squeezed light allowing 64% faster observations, thus improving the sensitivity to dynamic biological changes. This experiment was then extended to spatially resolved quantum imaging, with lipid particles used as scanning probes in a technique called photonic force microscopy. The particles sample variations in the local environment with resolution limited by measurement precision rather than the diffraction limit. The use of squeezed light was found to enhance spatial resolution by 14% at an absolute resolution level of 10 nm, comparable to leading classical experiments. This was the first demonstration of both sub-diffraction limited resolution and quantum enhanced resolution in biology, and places practical applications of quantum imaging within reach. Finally, the future challenges and prospects of quantum enhanced particle tracking are outlined.n
The displacement of micro-electro-mechanical-systems (MEMS) cantilevers is used to measure a broad variety of phenomena in devices ranging from force microscopes to biochemical sensors to thermal imaging systems. We demonstrate the first direct measurement of a MEMS cantilever displacement with a noise floor at 40% of the shot noise limit (SNL). By combining multi-spatial-mode quantum light sources with a simple differential measurement, we show that sub-SNL MEMS displacement sensitivity is highly accessible compared to previous efforts that measured the displacement of macroscopic mirrors with very distinct spatial structures crafted with multiple optical parametric amplifiers and locking loops. These results support a new class of quantum MEMS sensor with an ultimate signal to noise ratio determined by quantum correlations, enabling ultra-trace sensing, imaging, and microscopy applications in which signals were previously obscured by shot noise.
The ultimate sensitivity of any optically based measurement using classical resources (for example, laser or thermal light) is constrained by the photon shot noise limit (SNL). However, quantum states of light, in which photon pairs have quantum correlations or entanglement, off er a path beyond this limit. In particular, “squeezing” in these quantum states makes it possible to lower the noise in the detection system below the SNL. This can signifi cantly enhance the sensitivity of real-world devices and could thus revolutionize optical-based sensing applications
Quantum enhanced optical measurement protocols aim at reducing the uncertainty in the estimation of some physical quantities of a system below the shot-noise limit, classically unavoidable. In particular when small number of photons is used the shot noise can be the main source of uncertainty, in these cases the use of quantum light is of great interest. Note that there are several situations where the number of photons in the probe can not be increased arbitrarily, as when fragile biological samples are under investigation. Two different imaging protocols are discussed in the following.
Non-conventional receivers for phase-coherent states based on non-Gaussian measurements such as photon counting surpass the sensitivity limits of shot-noise-limited coherent receivers, the quantum noise limit (QNL). These non-Gaussian receivers can have a significant impact in future coherent communication technologies. However, random phase changes in realistic communication channels, such as optical fibers, present serious challenges for extracting the information encoded in coherent states. While there are methods for correcting random phase noise with conventional heterodyne detection, phase-tracking for non-Gaussian receivers surpassing the QNL is still an open problem. Here we demonstrate phase tracking for non-Gaussian receivers to correct for time-varying phase noise while allowing for decoding beyond the QNL. The phase-tracking method performs real-time parameter estimation and correction of phase drifts using the data from the non-Gaussian discrimination measurement, without relying on phase reference pilot fields. This method enables non-Gaussian receivers to achieve higher sensitivities and rates of information transfer than ideal coherent receivers in realistic channels with time-varying phase noise. This demonstration makes sub-QNL receivers a more robust, feasible, and practical quantum technology for classical and quantum communications.