Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Design of the new NIM6 fountain with collecting atoms from a 3D MOT loading optical molasses

Fang Fang, Weiliang Chen, Kun Liu, Nianfeng Liu, Rui Suo, Tianchu Li

Published Apr 1, 2015• 7 citations
Publisher

Abstract

We report the design of a new cesium fountain clock NIM6, which is under construction in NIM. Besides some improvements on the vacuum system, Ramsey cavity and microwave synthesizer to reduce the Type B uncertainty. Another major improvement on NIM6 is to collect more atoms from a MOT loading optical molasses and optical pumping to get a better signal to noise ratio at the detection. The atom distribution will be more uniform compared with a 2D MOT loading optical molasses, and the diameter of the cloud can be adjusted by the intensity and detuning of lights during the post cooling to keep the collisional-induced frequency shift low. The atom numbers can be further increased by a new de-pumping - optical pumping procedure to pump atoms to the |F=3, mF=0> clock state directly. With a new cryogenic sapphire oscillator (CSO) based frequency synthesizer, NIM6 is aiming to reach the quantum projection noise, thus leading to a reduced Type A uncertainty compared with NIM5.

DOI
10.1109/fcs.2015.7138891

Related papers

The progress of the NIM6 fountain clock in NIM

Fang Fang, Weiliang Chen, Kun Liu +4 more

A new fountain clock NIM6 is under construction. Besides some improvements on the vacuum system, a new Ramsey cavity and a microwave synthesizer are made to reduce the Type B uncertainty. Another feature of NIM6 is collecting atoms from a MOT loading optical molasses to get more atoms with a more uniform density distribution. With a new ultra-stable microwave frequency synthesizer based on cryogenic sapphire oscillator (CSO) or ultra-stable laser, NIM6 is aiming to reach the quantum projection noise, thus leading to a reduced Type A uncertainty.

URSI General Assembly and Scientific Symposium•Aug 1, 2017•2 citations

The preliminary evaluation of the new fountain clock NIM6

Fang Fang, Weiliang Chen, Kun Liu +3 more

In this paper, we introduce the design of our new fountain clock NIM6. Besides some improvements on the vacuum system, Ramsey cavity to reduce the Type B uncertainty, NIM6 collects atoms from a MOT loading optical molasses to get a better signal to noise ratio. The atom density will be more uniform compared to a 2D MOT loading optical molasses, and the diameter of the cloud can be adjusted by the intensity and detuning of lights during the post cooling after MOT to keep the collisional shift low. Cs atoms are collected in the lower MOT chamber for 0.5 second, and then the MOT magnetic field is turned down. Atoms are accelerated for 1 ms in a moving molasses, and further cooled for another 1.5 ms by adiabatically reducing the cooling beam intensities and red offsetting the frequencies.

URSI Asia-Pacific Radio Science Conference•Mar 1, 2019•4 citations

Loading a fountain clock with an enhanced low-velocity intense source of atoms

G. Dobrev, Vladislav P. Gerginov, S. Weyers

We present experimental work for improved atom loading in the optical molasses of a cesium fountain clock, employing a low-velocity intense source of atoms [Lu et al., Phys. Rev. Lett 77, 3331 (1996)], which we modify by adding a dark-state pump laser. With this modification the atom source has a mean flux of $4\ifmmode\times\else\texttimes\fi{}{10}^{8}$ atoms/s at a mean atom velocity of $8.6$ m/s. Compared to fountain operation using background gas loading, we achieve a significant increase of the loaded and detected atom number by a factor of 40. Operating the fountain clock with a total number of detected atoms ${N}_{\mathrm{at}}=2.9\ifmmode\times\else\texttimes\fi{}{10}^{6}$ in the quantum projection noise-limited regime, a frequency instability ${\ensuremath{\sigma}}_{y}(1s)=2.7\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ is demonstrated.

arXiv:1601.04852•Physical Review A•Apr 27, 2016•6 citations

Preliminary progress of the state preparation with a new optical pumping method in a cesium atomic fountain clock

Lei Han, Fang Fang, Yani Zuo +5 more

In this paper, a new optical pumping method, redistributing the atom populations among the Zeeman magnetic sublevels of the ground state |F=3> is proposed as the state preparation process to improve the signal to noise ratio (SNR) of the atomic fountain clock with a larger atom population on the |F=3, mF=0>clock state. A preliminary experimental result of state preparation efficiency exceeding 60% is obtained on the NIM6 cesium (Cs) fountain clock.

Quantum Optics and Photon Counting•Apr 14, 2021•0 citations

Improvement of the short-term stability of atomic fountain clock with state preparation by two-laser optical pumping*

Lei Han, Fang Fang, Weiliang Chen +4 more

To improve the signal to noise ratio (SNR) and the short-term stability of cesium atomic fountain clocks, the work of two-laser optical pumping is presented theoretically and experimentally. The short-term stability of the NIM6 fountain clock has been improved by preparing more cold atoms in the | F = 4, mF = 0〉 clock state with a shortened cycle time. Two π-polarized laser beams overlapped in the horizontal plane have been applied after launching, one is resonant with | F = 4〉 → | F′ = 4〉 transition and the other is resonant with | F = 3〉 → | F′ = 4〉 transition. With optical pumping, the population accumulated in the | mF = 0〉 clock state is improved from 11% to 63%, and the detection signal is increased by a factor of 4.2, the SNR of the clock transition probability and the short-term stability are also improved accordingly.

Chinese Physics B•Feb 2, 2021•4 citations

Progress on the construction of an atomic cesium fountain at NIM

Tianchu Li, Mingshou Li, Huang Bingying +2 more

An atomic cesium fountain has been designed for a new primary standard of frequency in China. Cold atomic clouds collected in the magneto-optical trap (MOT) were previously reported (1995). To further improve the performance of the MOT we have optimized the laser-optical system and operation of the MOT. Some optical elements were replaced with new ones with better quality; frequency stabilization of lasers and arrangement of the optical system was modified; and polarization maintaining (PM) optical fibers were adopted to transfer lights from the optical system to MOT. We also installed the fluorescence detecting - amplifying assembles to take the time of flight (TOF) measurement of the cold atoms.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 13, 2002•1 citation
We report the design of a new cesium fountain clock NIM6, which is under construction in NIM. Besides some improvements on the vacuum system, Ramsey cavity and microwave synthesizer to reduce the Type B uncertainty. Another major improvement on NIM6 is to collect more atoms from a MOT loading optical molasses and optical pumping to get a better signal to noise ratio at the detection. The atom distribution will be more uniform compared with a 2D MOT loading optical molasses, and the diameter of the cloud can be adjusted by the intensity and detuning of lights during the post cooling to keep the collisional-induced frequency shift low. The atom numbers can be further increased by a new de-pumping - optical pumping procedure to pump atoms to the |F=3, mF=0> clock state directly. With a new cryogenic sapphire oscillator (CSO) based frequency synthesizer, NIM6 is aiming to reach the quantum projection noise, thus leading to a reduced Type A uncertainty compared with NIM5.
A new fountain clock NIM6 is under construction. Besides some improvements on the vacuum system, a new Ramsey cavity and a microwave synthesizer are made to reduce the Type B uncertainty. Another feature of NIM6 is collecting atoms from a MOT loading optical molasses to get more atoms with a more uniform density distribution. With a new ultra-stable microwave frequency synthesizer based on cryogenic sapphire oscillator (CSO) or ultra-stable laser, NIM6 is aiming to reach the quantum projection noise, thus leading to a reduced Type A uncertainty.
In this paper, we introduce the design of our new fountain clock NIM6. Besides some improvements on the vacuum system, Ramsey cavity to reduce the Type B uncertainty, NIM6 collects atoms from a MOT loading optical molasses to get a better signal to noise ratio. The atom density will be more uniform compared to a 2D MOT loading optical molasses, and the diameter of the cloud can be adjusted by the intensity and detuning of lights during the post cooling after MOT to keep the collisional shift low. Cs atoms are collected in the lower MOT chamber for 0.5 second, and then the MOT magnetic field is turned down. Atoms are accelerated for 1 ms in a moving molasses, and further cooled for another 1.5 ms by adiabatically reducing the cooling beam intensities and red offsetting the frequencies.
We present experimental work for improved atom loading in the optical molasses of a cesium fountain clock, employing a low-velocity intense source of atoms [Lu et al., Phys. Rev. Lett 77, 3331 (1996)], which we modify by adding a dark-state pump laser. With this modification the atom source has a mean flux of $4\ifmmode\times\else\texttimes\fi{}{10}^{8}$ atoms/s at a mean atom velocity of 8.68.68.6 m/s. Compared to fountain operation using background gas loading, we achieve a significant increase of the loaded and detected atom number by a factor of 40. Operating the fountain clock with a total number of detected atoms ${N}_{\mathrm{at}}=2.9\ifmmode\times\else\texttimes\fi{}{10}^{6}$ in the quantum projection noise-limited regime, a frequency instability ${\ensuremath{\sigma}}_{y}(1s)=2.7\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ is demonstrated.
To improve the signal to noise ratio (SNR) and the short-term stability of cesium atomic fountain clocks, the work of two-laser optical pumping is presented theoretically and experimentally. The short-term stability of the NIM6 fountain clock has been improved by preparing more cold atoms in the | F = 4, mF = 0〉 clock state with a shortened cycle time. Two π-polarized laser beams overlapped in the horizontal plane have been applied after launching, one is resonant with | F = 4〉 → | F′ = 4〉 transition and the other is resonant with | F = 3〉 → | F′ = 4〉 transition. With optical pumping, the population accumulated in the | mF = 0〉 clock state is improved from 11% to 63%, and the detection signal is increased by a factor of 4.2, the SNR of the clock transition probability and the short-term stability are also improved accordingly.
An atomic cesium fountain has been designed for a new primary standard of frequency in China. Cold atomic clouds collected in the magneto-optical trap (MOT) were previously reported (1995). To further improve the performance of the MOT we have optimized the laser-optical system and operation of the MOT. Some optical elements were replaced with new ones with better quality; frequency stabilization of lasers and arrangement of the optical system was modified; and polarization maintaining (PM) optical fibers were adopted to transfer lights from the optical system to MOT. We also installed the fluorescence detecting - amplifying assembles to take the time of flight (TOF) measurement of the cold atoms.