Atom detection and counting in ultracold gases using photoionisation and ion detection
T. J. Campey
Abstract
In recent years there has been increasing interest in quantum atom optics, in which the discretenature of atoms plays an important role. As such, the ability to resolve atoms at the singleatom level has become important.This thesis investigates detecting atoms using photoionisation and ion detection. Thismethod is applicable to all atoms in common use in atom optics experiments, enables theirdetection with high e±ciency, allows atom counting with sub-Poissonian resolution (¾N < pN)and is applicable for large atom numbers (up to » 105). Two approaches towards atom detectionvia photoionisation and ion detection are examined, di®ering in the rate of photoionisation. Fastphotoionisation of individual atoms can be used for detecting a series of single atoms, such asmight be produced with an atom laser. Slow ionisation is required for counting large numbersof atoms contained in a single region, due to the necessity of being able to resolve the individualions with the ion detector. The application of these methods to 87Rb is examined, althoughthey can be adapted to other atoms.The scheme for quickly detecting single atoms uses STImulated Raman Adiabatic Passage(STIRAP) to excite 87Rb atoms to the 5D5=2 level followed by ionisation from this level usinga Nd:YAG laser pulse. Simulations and experiments were carried out and used to predict thatexcitation to the 5D5=2 level can be achieved with close to 100% e±ciency, and to show theexperimental parameters required. The photoionisation cross-section of 87Rb in the 5D5=2 stateusing 1064 nm light was measured in order to predict the photoionisation e±ciency that maybe achieved, which was found to approach 100%.The scheme for atom counting uses 2£778 nm photon excitation to raise atoms to the5D5=2 state followed by ionisation from this state using a cw Nd:YAG laser. The statisticsof atom counting are examined and used to ¯nd the counting accuracy as a function of thedetection e±ciency and its uncertainty. For a precisely calibrated detector, sub-Poissoniancounting is possible for detection e±ciencies greater than 50%. The e®ect of losses and the useof the scheme for measuring number squeezing are examined. Achieving low count uncertaintiesrequires measuring the ion detection e±ciency to high accuracy. A method for doing this isproposed and analysed, and experiments were carried out to measure the ion detection e±ciencyof an ion detector in a mock experimental setup. A detailed scheme is proposed and analysed for measuring number di®erence squeezing ina RF induced double well potential using atom counting via photoionisation and ion detection.Simulations of the double well potential were performed to show how even splitting can beachieved and the degree of squeezing expected to occur. A design for an experimental setup isdescribed and analysed in detail, in order to show the accuracy with which number di®erencesqueezing can be measured.