Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America A

Coherent Transients by Laser-Acoustical Diffraction Spectroscopy

A. H. Zewail

Published May 1, 1978• 1 citation
Publisher

Abstract

Recently we have reported[1] on the measurements of electronic dephasing (T_2) and radiationless decay (T_1) in molecules using emission spectroscopy as a probe for the detection of the photon echo. This right-angle photon echo utilizes a single mode of a narrow-band (~MHz) cw dye laser and an intracavity electro-optical (EO) element that modulates the frequency of the laser.[2] Applying voltage pulses into the EO crystal switches the laser frequency from ω_0 (the peak frequency of the transition resonance) into another frequency ω. This switching procedure introduced by Brewer et al. for the observation of transients in the forward direction of the laser allows one to observe coherent transients in gases,[1,2] solids[3-5] and molecular beams.[6] Typically, the dispersion of the nonlinear EO crystal (e.g., AD*P) gives a 60 MHz frequency shift within the inhomogeneous resonance of the optical transition (width ~GHz or larger). Therefore, to switch the laser frequency further, one must use high-voltage signals that are usually hard to obtain especially for multiple-pulse experiments. Secondly, there is a limit on the frequency shift which is conditioned by the mode spacing of the cavity. Thirdly, because the laser is switched into a new group of molecules some complications may arise in interpreting the transient spectra especially in large molecules. This is because in large molecules the density of excited states is high and thus the buildup of transients of w molecules (which could be complex) will be superimposed on the decay of ω_0 molecules. Finally, off-resonance effects (e.g., beats) between the molecules at frequency ω and ω_0 cannot be avoided.

DOI
10.1364/josa.68.000623

Related papers

Optical coherent transients by laser frequency switching

Azriel Z. Genack, Richard G. Brewer

A simple method for observing coherent optical-transient phenomena is described. Effects such as photon echoes and free induction decay (FID) should allow studies of the dynamic properties of atoms, molecules, and solids on a time scale ranging from milliseconds to \ensuremath{\sim} 50 ps. The frequency of a cw dye laser is switched with an intracavity electro-optic modulator, producing in an external sample coherent transients which are detected in the forward beam. Measurements of long dephasing times are possible, as in FID, because the laser can oscillate indefinitely at the new frequency following a step-function switching pulse. Measurements of short decay times are also practical because the switching time is not restricted by the laser gain or cavity ringing time. In addition, the dye's dephasing time of a few picoseconds or less is too rapid to interfere with these observations. Since the pulse sequence can be preselected, the entire class of coherent optical transients is accessible. The method thus incorporates all of the advantages inherent in Stark switching, including heterodyne detection and high sensitivity, without being restricted to Stark-tunable systems. Laser frequency switching is discussed also in terms of a theoretical model which exposes the time-dependent properties of a phase-modulated cavity mode. Dephasing studies have been carried out thus far in atomic and molecular gases and low-temperature solids containing inorganic impurity ions or large organic molecules. The utility of the FID effect is emphasized where precise dephasing times are obtained from time-frequency Fourier transformation of FID signals using a digital computer. The first quantitative and detailed test of FID theory is provided by these experimental techniques.

Physical Review A•Apr 1, 1978•65 citations

Ultrafast coherent transients & excited state dynamics in gases and solids

Daniel Dawson

I. A new technique utilizing the electro-optic frequency switching of a single mode ( 6 Mhz) dye laser was used to observe free induction decay and optical nutation in iodine gas and optical nutation in an organic mixed crystal (pentacene in p-terphenyl) at low temperature. A new technique, incoherent resonance decay (IRO) was also developed. These experiments allow one to determine T_1 and T_2, the longitudinal and transverse relaxation times of the excited ensemble, in analogy with magnetic resonance. For I_2(g) at O∙C; T_l = 2.3 x 10^(-7) sec, T_2 ≃ 1 x 10^(-7) sec. These techniques are limited to a time scale > 10 nsec. II. The construction and characterization of cw, mode-locked dye laser capable of putting out a continuous train of reproducible sub-picosecond pulses is described. Experiments utilizing this laser for the measurement of picosecond coherent transients and time resolved absorption spectroscopy are proposed.

•Jan 1, 1978•0 citations

A Novel Laser Technique for Observing Optical Coherence in Gases, Molecular Beams, and Solids

Thomas E. Orlowski, A. H. Zewail

Traditionally, the phenomenon of optical coherence has been observed by detecting coherent transients (i.e., optical nutation, FID, photon echoes) propagating along the laser beam following passage through an absorbing medium. Recently, we have demonstrated that detection of the incoherent (spontaneous) emission from selectively prepared states provides the optical coherence of the ensemble. Our observation of the nutation and the photon echo at right angles to the exciting beam gives directly optical T_1, T_2, and the moment of the laser excited transition. This technique is simple and not susceptible to some of the problems inherent in coherent absorption experiments. Details about this laser technique will be presented. We will also discuss the different dynamical information one obtains about excited states in gases, molecular beams and solids.

•Jan 1, 1977•0 citations

Electro-Optic Generation Of Coherent Optical Transients

D. Anafi, Azriel Z. Genack

Optical Transient Experiments allow one to probe the coherent interaction of light with matter, as well as measure the time for energy transfer, T1, and loss of phase coherence, T2, in atoms, molecules and solids. Coherent optical transients are induced when the interaction of light with the sample is changed in a time which is short compared to T2. The interaction can be modified by changing the amplitude, frequency or phase of the existing laser light. This can be accomplished with an electro-optic modulator which makes it possible to electronically control a wide variety of laser experiments. The method of electro-optic laser phase and frequency switching with an extra-cavity modulator is discussed below.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 30, 1980•0 citations

Coherent transients in molecular gases: comparison of two techniques

Н. Н. Рубцова

Each of three basic coherent transient phenomena (optical nutation, free polarization decay photon echo) can be generated by sufficiently abrupt modulation of the interaction between the matter and radiation. This can be performed by rapid commutation of either radiation parameters, or the parameters of the matter. I present here comparative analysis of these two approaches (the first one, using electro-optical switching of the resonant laser power to create the pulses for the gas excitation and the second one, based on the Stark switching of vibro-rotational levels in a gas, excited by CW laser radiation), used in our experiments in molecular gases, from the point of view of both their capability to generate various coherent transients and their sensitivity to the intensity of laser radiation.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 15, 2001•0 citations

cw photon echo: Theory and observations

Masaharu Mitsunaga

A novel coherent transient spectroscopy, cw photon echo, is described. A medium is exposed to broadband cw laser radiation and then to a pulsed laser, resulting in a continuous emission signal from the medium. The temporal profile of this signal is studied using full density-matrix theory for the cases of a two-level system and a multilevel system. It is shown that such signal decays with a homogeneous dephasing time ${\mathit{T}}_{2}$ and can have a quantum-beat-type modulation, reproducing in a single shot the conventional two-pulse photon echo plot versus first-to-second pulse separation. Experimental demonstrations are given for the $^{7}$${\mathit{F}}_{0}$${\mathrm{\ensuremath{-}}}^{5}$${\mathit{D}}_{0}$ transition of ${\mathrm{Eu}}^{3+}$ and the $^{3}$${\mathit{H}}_{4}$${\mathrm{\ensuremath{-}}}^{1}$${\mathit{D}}_{2}$ transition of ${\mathrm{Pr}}^{3+}$; both ions are doped in ${\mathrm{YAlO}}_{3}$. The Eu ions exhibit a single exponential decay with a slight modulation due to the ground-state hyperfine splittings. The temperature dependence of the signal is also studied. The Pr ions show a very deep modulation pattern, which provides excellent agreement with the independent two pulse echo measurement. A numerical simulation based on the modulation theory also agrees with the observed decay curves and the nuclear axis configuration in this crystal is discussed.

Physical Review A•Aug 1, 1990•13 citations
Recently we have reported[1] on the measurements of electronic dephasing (T_2) and radiationless decay (T_1) in molecules using emission spectroscopy as a probe for the detection of the photon echo. This right-angle photon echo utilizes a single mode of a narrow-band (~MHz) cw dye laser and an intracavity electro-optical (EO) element that modulates the frequency of the laser.[2] Applying voltage pulses into the EO crystal switches the laser frequency from ω_0 (the peak frequency of the transition resonance) into another frequency ω. This switching procedure introduced by Brewer et al. for the observation of transients in the forward direction of the laser allows one to observe coherent transients in gases,[1,2] solids[3-5] and molecular beams.[6] Typically, the dispersion of the nonlinear EO crystal (e.g., AD*P) gives a 60 MHz frequency shift within the inhomogeneous resonance of the optical transition (width ~GHz or larger). Therefore, to switch the laser frequency further, one must use high-voltage signals that are usually hard to obtain especially for multiple-pulse experiments. Secondly, there is a limit on the frequency shift which is conditioned by the mode spacing of the cavity. Thirdly, because the laser is switched into a new group of molecules some complications may arise in interpreting the transient spectra especially in large molecules. This is because in large molecules the density of excited states is high and thus the buildup of transients of w molecules (which could be complex) will be superimposed on the decay of ω_0 molecules. Finally, off-resonance effects (e.g., beats) between the molecules at frequency ω and ω_0 cannot be avoided.
A simple method for observing coherent optical-transient phenomena is described. Effects such as photon echoes and free induction decay (FID) should allow studies of the dynamic properties of atoms, molecules, and solids on a time scale ranging from milliseconds to \ensuremath{\sim} 50 ps. The frequency of a cw dye laser is switched with an intracavity electro-optic modulator, producing in an external sample coherent transients which are detected in the forward beam. Measurements of long dephasing times are possible, as in FID, because the laser can oscillate indefinitely at the new frequency following a step-function switching pulse. Measurements of short decay times are also practical because the switching time is not restricted by the laser gain or cavity ringing time. In addition, the dye's dephasing time of a few picoseconds or less is too rapid to interfere with these observations. Since the pulse sequence can be preselected, the entire class of coherent optical transients is accessible. The method thus incorporates all of the advantages inherent in Stark switching, including heterodyne detection and high sensitivity, without being restricted to Stark-tunable systems. Laser frequency switching is discussed also in terms of a theoretical model which exposes the time-dependent properties of a phase-modulated cavity mode. Dephasing studies have been carried out thus far in atomic and molecular gases and low-temperature solids containing inorganic impurity ions or large organic molecules. The utility of the FID effect is emphasized where precise dephasing times are obtained from time-frequency Fourier transformation of FID signals using a digital computer. The first quantitative and detailed test of FID theory is provided by these experimental techniques.
I. A new technique utilizing the electro-optic frequency switching of a single mode ( 6 Mhz) dye laser was used to observe free induction decay and optical nutation in iodine gas and optical nutation in an organic mixed crystal (pentacene in p-terphenyl) at low temperature. A new technique, incoherent resonance decay (IRO) was also developed. These experiments allow one to determine T_1 and T_2, the longitudinal and transverse relaxation times of the excited ensemble, in analogy with magnetic resonance. For I_2(g) at O∙C; T_l = 2.3 x 10^(-7) sec, T_2 ≃ 1 x 10^(-7) sec. These techniques are limited to a time scale > 10 nsec. II. The construction and characterization of cw, mode-locked dye laser capable of putting out a continuous train of reproducible sub-picosecond pulses is described. Experiments utilizing this laser for the measurement of picosecond coherent transients and time resolved absorption spectroscopy are proposed.
Traditionally, the phenomenon of optical coherence has been observed by detecting coherent transients (i.e., optical nutation, FID, photon echoes) propagating along the laser beam following passage through an absorbing medium. Recently, we have demonstrated that detection of the incoherent (spontaneous) emission from selectively prepared states provides the optical coherence of the ensemble. Our observation of the nutation and the photon echo at right angles to the exciting beam gives directly optical T_1, T_2, and the moment of the laser excited transition. This technique is simple and not susceptible to some of the problems inherent in coherent absorption experiments. Details about this laser technique will be presented. We will also discuss the different dynamical information one obtains about excited states in gases, molecular beams and solids.
Optical Transient Experiments allow one to probe the coherent interaction of light with matter, as well as measure the time for energy transfer, T1, and loss of phase coherence, T2, in atoms, molecules and solids. Coherent optical transients are induced when the interaction of light with the sample is changed in a time which is short compared to T2. The interaction can be modified by changing the amplitude, frequency or phase of the existing laser light. This can be accomplished with an electro-optic modulator which makes it possible to electronically control a wide variety of laser experiments. The method of electro-optic laser phase and frequency switching with an extra-cavity modulator is discussed below.
Each of three basic coherent transient phenomena (optical nutation, free polarization decay photon echo) can be generated by sufficiently abrupt modulation of the interaction between the matter and radiation. This can be performed by rapid commutation of either radiation parameters, or the parameters of the matter. I present here comparative analysis of these two approaches (the first one, using electro-optical switching of the resonant laser power to create the pulses for the gas excitation and the second one, based on the Stark switching of vibro-rotational levels in a gas, excited by CW laser radiation), used in our experiments in molecular gases, from the point of view of both their capability to generate various coherent transients and their sensitivity to the intensity of laser radiation.
A novel coherent transient spectroscopy, cw photon echo, is described. A medium is exposed to broadband cw laser radiation and then to a pulsed laser, resulting in a continuous emission signal from the medium. The temporal profile of this signal is studied using full density-matrix theory for the cases of a two-level system and a multilevel system. It is shown that such signal decays with a homogeneous dephasing time T2{\mathit{T}}_{2}T2​ and can have a quantum-beat-type modulation, reproducing in a single shot the conventional two-pulse photon echo plot versus first-to-second pulse separation. Experimental demonstrations are given for the 7^{7}7F0{\mathit{F}}_{0}F0​${\mathrm{\ensuremath{-}}}^{5}$D0{\mathit{D}}_{0}D0​ transition of Eu3+{\mathrm{Eu}}^{3+}Eu3+ and the 3^{3}3H4{\mathit{H}}_{4}H4​${\mathrm{\ensuremath{-}}}^{1}$D2{\mathit{D}}_{2}D2​ transition of Pr3+{\mathrm{Pr}}^{3+}Pr3+; both ions are doped in YAlO3{\mathrm{YAlO}}_{3}YAlO3​. The Eu ions exhibit a single exponential decay with a slight modulation due to the ground-state hyperfine splittings. The temperature dependence of the signal is also studied. The Pr ions show a very deep modulation pattern, which provides excellent agreement with the independent two pulse echo measurement. A numerical simulation based on the modulation theory also agrees with the observed decay curves and the nuclear axis configuration in this crystal is discussed.