Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

A 4$pi$ GEOMETRY DEVICE FOR STUDYING TIME CORRELATION OF PHOTONS EMITTED BY VARIOUS GAS ATOMS

Yu.F. Skachkov

Published Sep 1, 1964• 0 citations
OpenAlex

Related papers

INVESTIGATION OF THE TIME CORRELATION OF PHOTONS EMITTED IN THE NeII SPECTRAL LINES OF SEPARATE NEON ATOMS EXCITED BY ELECTRON IMPACT

Yu.F. Skachkov

•Apr 1, 1964•0 citations

Investigation of the time correlation of photons emitted by excited argon atoms

Vacuum•Jul 1, 1967•0 citations

Time Correlation of Photons Emitted by Excited Xenon Atoms

Yu.F. Skachkov

Journal of Experimental and Theoretical Physics•Jun 1, 1969•0 citations

Superconducting nanowire single electron detector

Michaël Rosticher, F. R. Ladan, J. P. Maneval +6 more

WE REPORT THE DETECTION OF SINGLE ELECTRONS USING A 6 NM-THICK, 100 NM-WIDE, NB0.7TI0.3N SUPERCONDUCTING STRIP DEPOSITED ON A SIOX/SI SUBSTRATE. WHEN BIASED SLIGHTLY BELOW THE CRITICAL CURRENT, A MEANDER-SHAPED DEVICE, NOT ONLY DETECTS SINGLE PHOTONS, BUT ALSO COUNTS THE SINGLE KEV ELECTRONS ISSUED FROM A SCANNING ELECTRON MICROSCOPE (SEM) WITH AN EFFICIENCY APPROACHING UNITY. THE RESPONSE TIME IS SHORT ENOUGH TO DISCRIMINATE THE INCIDENT ELECTRONS FROM THOSE BACKSCATTERED FROM THE UNDERLYING MATERIAL. IT IS THEREFORE POSSIBLE TO MAP THE ELECTRON DETECTIVITY AS WELL AS THE PHOTON DETECTIVITY ON THE SAME DEVICE. A CLEAR CORRELATION BETWEEN THE TWO MEASUREMENTS IS OBSERVED, WITH A SUPERIOR SPATIAL RESOLUTION THOUGH (AROUND 100 NM) FOR THE SEM MAPPING. IT ILLUSTRATES THE POTENTIAL USE OF THIS SINGLE ELECTRON MAPPING BY THE SEM METHOD TO CHARACTERIZE THE DETECTION HOMOGENEITY OF SSPDS

•Aug 1, 2010•0 citations

Time correlations in the detection of successively emitted photons

Carl A. Kocher

Annals of Physics•Jan 1, 1971•27 citations

UTILIZATION OF TWO-TIME TEMPERATURE FORMALISM FOR STUDYING QUASIPARTICLE EXCITATIONS OF HIGH DENSITY FERMI-GAS SYSTEMS.

Vladimir D. Ozrin

•Jan 1, 1968•0 citations
A 4pipipi GEOMETRY DEVICE FOR STUDYING TIME CORRELATION OF PHOTONS EMITTED BY VARIOUS GAS ATOMS
WE REPORT THE DETECTION OF SINGLE ELECTRONS USING A 6 NM-THICK, 100 NM-WIDE, NB0.7TI0.3N SUPERCONDUCTING STRIP DEPOSITED ON A SIOX/SI SUBSTRATE. WHEN BIASED SLIGHTLY BELOW THE CRITICAL CURRENT, A MEANDER-SHAPED DEVICE, NOT ONLY DETECTS SINGLE PHOTONS, BUT ALSO COUNTS THE SINGLE KEV ELECTRONS ISSUED FROM A SCANNING ELECTRON MICROSCOPE (SEM) WITH AN EFFICIENCY APPROACHING UNITY. THE RESPONSE TIME IS SHORT ENOUGH TO DISCRIMINATE THE INCIDENT ELECTRONS FROM THOSE BACKSCATTERED FROM THE UNDERLYING MATERIAL. IT IS THEREFORE POSSIBLE TO MAP THE ELECTRON DETECTIVITY AS WELL AS THE PHOTON DETECTIVITY ON THE SAME DEVICE. A CLEAR CORRELATION BETWEEN THE TWO MEASUREMENTS IS OBSERVED, WITH A SUPERIOR SPATIAL RESOLUTION THOUGH (AROUND 100 NM) FOR THE SEM MAPPING. IT ILLUSTRATES THE POTENTIAL USE OF THIS SINGLE ELECTRON MAPPING BY THE SEM METHOD TO CHARACTERIZE THE DETECTION HOMOGENEITY OF SSPDS