Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Shandong University

受激Raman散射(SRS)的研究:I.散射过程的速率方程

夏海瑞

Published Jan 1, 1993• 0 citations
OpenAlex

Abstract

通过对克雷末斯—海森堡色散公式中求和规则的分析,讨论了虑态在SRS中桥接跃迁过程的作用,从而提出了SRS的物理机制,在此基础上,引进一个假设,建立理论模型,导出了第一阶Stokes光子的速率方程。

Related papers

Raman型原子—腔场系统N—qubit原子态的隐形传送

张信华, 杨志勇, 王菊霞 +1 more

利用全量子理论,对简并A型三能级原子与单模相干态的相反态腔场之间的Raman相互作用进行了详细研究。在此基础上,提出了利用简并A型三能级原子与腔场之间的Raman相互作用,来臆形传送N-qubit未知原子态的新方案。

Electronic Science and Technology•Jan 1, 2009•0 citations

带电子自旋效应的球Raman-Nath方程

三奎 苟

Chinese Science Bulletin (Chinese Version)•Dec 1, 1990•0 citations

Stimulated Raman scattering spectroscopy with quantum-enhanced balanced detection

Zicong Xu, Kenichi Oguchi, Yoshitaka Taguchi +5 more

Quantum-enhanced stimulated Raman scattering (QE-SRS) is a promising technique for highly sensitive molecular vibrational imaging and spectroscopy surpassing the shot noise limit. However, the previous demonstrations of QE-SRS utilized rather weak optical power which hinders from competing with the sensitivity of state-of-the-art SRS microscopy and spectroscopy using relatively high-power optical pulses. Here, we demonstrate SRS spectroscopy with quantum-enhanced balanced detection (QE-BD) scheme, which works even when using high-power optical pulses. We used 4-ps pulses to generate pulsed squeezed vacuum at a wavelength of 844 nm with a squeezing level of −3.28 ± 0.12 dB generated from a periodically-poled stoichiometric LiTaO3 waveguide. The squeezed vacuum was introduced to an SRS spectrometer employing a high-speed spectral scanner to acquire QE-SRS spectrum in the wavenumber range of 2000–2280 cm-1 within 50 ms. Using SRS pump pulses with an average power of 11.3 mW, we successfully obtained QE-SRS spectrum whose SNR was better than classical SRS with balanced-detection by 2.27 dB.

Optics Express•May 4, 2022•34 citations

Quantum-enhanced stimulated Raman scattering microscopy toward breaking the shot noise limit in high-power regime

Kenichi Oguchi, Zicong Xu, Yoshitaka Taguchi +5 more

Stimulated Raman scattering (SRS) microscopy is a powerful technique that allows for the visualization of molecular vibrational images for label-free imaging, metabolic imaging, and supermultiplex imaging. However, its sensitivity is mainly limited by the shot noise of laser pulses, and long acquisition times are sometimes required to detect weak SRS signals hidden by the shot noise. To overcome this limitation, quantum-enhanced (QE-) SRS microscopy has been demonstrated, while the low optical power of squeezed pulses limits the sensitivity. In this work, we present QE-SRS microscopy using quantum-enhanced balanced detection (QE-BD) scheme, where the sensitivity of balanced detection SRS microscope is enhanced by injecting squeezed vacuum, allowing for QE-SRS imaging with high power SRS pump pulses (typically several tens of milliwatt), while balanced detection causes 3 dB drawback in the signal-to-noise ratio. We experimentally demonstrate QE-SRS imaging with 2.6 dB noise reduction compared with shot-noise-limited balanced detection SRS. We also demonstrate hyperspectral QE-SRS imaging by fast wavelength tuning of Stokes pulses. These results show the potential feasibility of high-power QE-SRS whose sensitivity is beyond that of classical shot-noise-limited SRS microscopes.

Advanced Chemical Microscopy for Life Science and Translational Medicine•Mar 15, 2023•0 citations

关于三光子Raman效应问题的讨论

朱振和

摘要 Abstract 作者及机构信息 朱振和 1. 中国科学技术大学,1964年应届毕业生 Authors and contacts 1. 中国科学技术大学,1964年应届毕业生 参考文献 [1] 施引文献

Acta Physica Sinica•Jan 1, 1965•1 citation

Quantum-Enhanced Stimulated Raman Scattering Spectroscopy in Dual-Polarization Scheme

Zicong Xu, Kenichi Oguchi, Sho Nitanai +3 more

Squeezed light has been applied in stimulated Raman scattering (SRS) spectroscopy [1] and microscopy [2] to break the shot-noise-limited sensitivity. The sub-shot-noise sensitivity achieved in quantum-enhanced SRS (QE-SRS) systems is advantageous for uncovering weak signals and achieving faster imaging speed, which attract the attention of biomedical scientists. To break the sensitivity of state-of-the-art SRS microscopes, the applied squeezed light power in QE-SRS systems should be high enough (>10mW). Recently, high-power picosecond-pulsed QE-SRS spectroscopy [3] based on balanced detection scheme [4] was reported, and a sensitivity that is comparable to state-of-the-art SRS microscopes was firstly demonstrated in QE-SRS microscopy based on the same scheme [5]. An important issue of QE-SRS based on balanced detection is the 3-dB additional noise, so >3-dB squeezing level is required to demonstrate an absolute sensitivity improvement compared with state-of-the-art SRS microscopes in single-photodiode detection scheme. However, it's hard to generate highly squeezed pulsed light because of the difficulty in temporal and spatial mode matching between squeezed vacuum (SQV) and local oscillator (LO). Here, we introduce QE-SRS in dual-polarization scheme, which can be implemented in high-power regime but is free from the 3-dB signal-to-noise ratio drawback.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•0 citations
Quantum-enhanced stimulated Raman scattering (QE-SRS) is a promising technique for highly sensitive molecular vibrational imaging and spectroscopy surpassing the shot noise limit. However, the previous demonstrations of QE-SRS utilized rather weak optical power which hinders from competing with the sensitivity of state-of-the-art SRS microscopy and spectroscopy using relatively high-power optical pulses. Here, we demonstrate SRS spectroscopy with quantum-enhanced balanced detection (QE-BD) scheme, which works even when using high-power optical pulses. We used 4-ps pulses to generate pulsed squeezed vacuum at a wavelength of 844 nm with a squeezing level of −3.28 ± 0.12 dB generated from a periodically-poled stoichiometric LiTaO3 waveguide. The squeezed vacuum was introduced to an SRS spectrometer employing a high-speed spectral scanner to acquire QE-SRS spectrum in the wavenumber range of 2000–2280 cm-1 within 50 ms. Using SRS pump pulses with an average power of 11.3 mW, we successfully obtained QE-SRS spectrum whose SNR was better than classical SRS with balanced-detection by 2.27 dB.
Stimulated Raman scattering (SRS) microscopy is a powerful technique that allows for the visualization of molecular vibrational images for label-free imaging, metabolic imaging, and supermultiplex imaging. However, its sensitivity is mainly limited by the shot noise of laser pulses, and long acquisition times are sometimes required to detect weak SRS signals hidden by the shot noise. To overcome this limitation, quantum-enhanced (QE-) SRS microscopy has been demonstrated, while the low optical power of squeezed pulses limits the sensitivity. In this work, we present QE-SRS microscopy using quantum-enhanced balanced detection (QE-BD) scheme, where the sensitivity of balanced detection SRS microscope is enhanced by injecting squeezed vacuum, allowing for QE-SRS imaging with high power SRS pump pulses (typically several tens of milliwatt), while balanced detection causes 3 dB drawback in the signal-to-noise ratio. We experimentally demonstrate QE-SRS imaging with 2.6 dB noise reduction compared with shot-noise-limited balanced detection SRS. We also demonstrate hyperspectral QE-SRS imaging by fast wavelength tuning of Stokes pulses. These results show the potential feasibility of high-power QE-SRS whose sensitivity is beyond that of classical shot-noise-limited SRS microscopes.
Squeezed light has been applied in stimulated Raman scattering (SRS) spectroscopy [1] and microscopy [2] to break the shot-noise-limited sensitivity. The sub-shot-noise sensitivity achieved in quantum-enhanced SRS (QE-SRS) systems is advantageous for uncovering weak signals and achieving faster imaging speed, which attract the attention of biomedical scientists. To break the sensitivity of state-of-the-art SRS microscopes, the applied squeezed light power in QE-SRS systems should be high enough (>10mW). Recently, high-power picosecond-pulsed QE-SRS spectroscopy [3] based on balanced detection scheme [4] was reported, and a sensitivity that is comparable to state-of-the-art SRS microscopes was firstly demonstrated in QE-SRS microscopy based on the same scheme [5]. An important issue of QE-SRS based on balanced detection is the 3-dB additional noise, so >3-dB squeezing level is required to demonstrate an absolute sensitivity improvement compared with state-of-the-art SRS microscopes in single-photodiode detection scheme. However, it's hard to generate highly squeezed pulsed light because of the difficulty in temporal and spatial mode matching between squeezed vacuum (SQV) and local oscillator (LO). Here, we introduce QE-SRS in dual-polarization scheme, which can be implemented in high-power regime but is free from the 3-dB signal-to-noise ratio drawback.