Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Zhur. Eksptl'. i Teoret. Fiz.

SINGLE-PHOTON ANNIHILATION AND ELECTRON PAIR PRODUCTION IN A MEDIUM

G. S. Saakyan

Published May 1, 1960• 0 citations
OpenAlex

Related papers

Probing Quantum Rules with Single-Photon Creation and Annihilation Operators

Zavatta A., Valentina Parigi, Bellini M.

•Jan 1, 2008•0 citations

A CUBESAT COMPATIBLE ELECTRONICS PLATFORM FOR MINIATURIZED SINGLE PHOTON PAIR SOURCES

CHANDRASEKARA MUDIYANSELAGE RAKHITHA BANDARA CHANDRASEKARA

•Dec 15, 2016•0 citations

Light-matter interaction at the single-photon level

L. Lanco

•Jun 13, 2022•0 citations

SINGLE PHOTON FREE-FREE TRANSITIONS

K L Bell

A brief review of single photon free-free transitions, in which a photon is absorbed by an electron in the presence of an atom, is presented.

Journal de Physique IV (Proceedings)•Mar 1, 1991•0 citations

Single-Photon Transitions of Atomic Particles

В. П. Крайнов, Boris Michailovich Smirnov

Springer series on atomic, optical, and plasma physics•Jan 1, 2019•0 citations

Superconducting nanowire single electron detector

Michaël Rosticher, F. R. Ladan, J. P. Maneval +6 more

WE REPORT THE DETECTION OF SINGLE ELECTRONS USING A 6 NM-THICK, 100 NM-WIDE, NB0.7TI0.3N SUPERCONDUCTING STRIP DEPOSITED ON A SIOX/SI SUBSTRATE. WHEN BIASED SLIGHTLY BELOW THE CRITICAL CURRENT, A MEANDER-SHAPED DEVICE, NOT ONLY DETECTS SINGLE PHOTONS, BUT ALSO COUNTS THE SINGLE KEV ELECTRONS ISSUED FROM A SCANNING ELECTRON MICROSCOPE (SEM) WITH AN EFFICIENCY APPROACHING UNITY. THE RESPONSE TIME IS SHORT ENOUGH TO DISCRIMINATE THE INCIDENT ELECTRONS FROM THOSE BACKSCATTERED FROM THE UNDERLYING MATERIAL. IT IS THEREFORE POSSIBLE TO MAP THE ELECTRON DETECTIVITY AS WELL AS THE PHOTON DETECTIVITY ON THE SAME DEVICE. A CLEAR CORRELATION BETWEEN THE TWO MEASUREMENTS IS OBSERVED, WITH A SUPERIOR SPATIAL RESOLUTION THOUGH (AROUND 100 NM) FOR THE SEM MAPPING. IT ILLUSTRATES THE POTENTIAL USE OF THIS SINGLE ELECTRON MAPPING BY THE SEM METHOD TO CHARACTERIZE THE DETECTION HOMOGENEITY OF SSPDS

•Aug 1, 2010•0 citations
WE REPORT THE DETECTION OF SINGLE ELECTRONS USING A 6 NM-THICK, 100 NM-WIDE, NB0.7TI0.3N SUPERCONDUCTING STRIP DEPOSITED ON A SIOX/SI SUBSTRATE. WHEN BIASED SLIGHTLY BELOW THE CRITICAL CURRENT, A MEANDER-SHAPED DEVICE, NOT ONLY DETECTS SINGLE PHOTONS, BUT ALSO COUNTS THE SINGLE KEV ELECTRONS ISSUED FROM A SCANNING ELECTRON MICROSCOPE (SEM) WITH AN EFFICIENCY APPROACHING UNITY. THE RESPONSE TIME IS SHORT ENOUGH TO DISCRIMINATE THE INCIDENT ELECTRONS FROM THOSE BACKSCATTERED FROM THE UNDERLYING MATERIAL. IT IS THEREFORE POSSIBLE TO MAP THE ELECTRON DETECTIVITY AS WELL AS THE PHOTON DETECTIVITY ON THE SAME DEVICE. A CLEAR CORRELATION BETWEEN THE TWO MEASUREMENTS IS OBSERVED, WITH A SUPERIOR SPATIAL RESOLUTION THOUGH (AROUND 100 NM) FOR THE SEM MAPPING. IT ILLUSTRATES THE POTENTIAL USE OF THIS SINGLE ELECTRON MAPPING BY THE SEM METHOD TO CHARACTERIZE THE DETECTION HOMOGENEITY OF SSPDS