Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2611.27328

60-cm-long In-vacuum Zerodur Optical Cavity for Optical Lattice Atom Interferometry

Philip Wondrak, Paola Luna, Kenneth Nakasone, Andrei Zhukov, Michael Grisham, Garrett D. Cole, Po-han Chen, Cristian D. Panda

physics.atom-phphysics.ins-detphysics.opticsquant-phSubmitted Nov 20, 2026• Announced Nov 23, 2026
arXivHTMLPDF

Abstract

Optical cavities are widely used in atomic physics experiments to control the spatial geometry and spectral properties of atom-light interactions. Recently, an optical lattice generated by the pristine mode of an optical cavity was utilized to hold and extend the quantum coherence of atomic spatial superpositions. Here, we describe an in-vacuum optical cavity designed to enhance the spatial and temporal coherence of optical lattice atom interferometers to one millimeter wavepacket separations and one minute measurement durations. The cavity uses a rigid Zerodur spacer to suppress the negative effects of thermal drift and mechanical-acoustic vibrations on the atomic motional state. The 60 cm-long cavity spacer provides ample optical access for the laser beams and imaging optics necessary for the preparation, quantum control, and read-out of the atomic state, as well as room for various source mass configurations for localized gravitational measurements. An integrated differential pumping structure enables compatibility with ultrahigh-vacuum operation and optical interferometry allows for in-situ vibration monitoring. The performance of the optical cavity is methodically characterized: we measure mirror vibration noise with amplitude below 5 nm/$\sqrt{\rm Hz}$ in a wide frequency range of 2 Hz - 100 kHz and a slow 15 MHz thermal drift of the cavity resonance over 47 hours, which can be readily stabilized with an integrated piezo. The optical cavity supports both 852-nm light for Raman transitions and 1064-nm light for the optical lattice, with a free spectral range matched to an integer divisor of the cesium ground-state hyperfine splitting.

Comments
12 pages, 5 figures

Related papers

Probing Gravity for One Minute with an Optical-Lattice Atom Interferometer

Cristian Daniel Panda, Matthew Tao, James Egelhoff +4 more

We have realized an atom interferometer that probes gravitational potentials by holding, rather than dropping, atoms. Up to one minute of coherence times are realized by suspending the spatially separated atomic wave packets in an optical lattice that is mode-filtered by an optical cavity. This trapped configuration suppresses phase variance due to vibrations by four to five orders of magnitude, overcoming the dominant noise source in atom-interferometric gravimeters. Recent progress in characterizing and reducing interferometer decoherence led to major increases in coherence and precision, paving the way to measurements of dark-energy candidates and probes of the quantum nature of gravity through measuring the gravity of source masses with record precision and spatial resolution.

arXiv:2301.13315•CPT and Lorentz Symmetry•May 1, 2023•5 citations

Hybrid quantum sensing using an optomechanical resonator coupled atom interferometer

Ashwin Rajagopalan

Quantum sensing using atom interferometry possesses immense potential for application in gravimetry, inertial navigation and for gravitational wave detection, apart from carrying out tests of fundamental physics. Atom interferometry can be used to perform absolute inertial measurements with unprecedented long term stability, unlike classical sensors which are prone to drift and incur calibration errors. However, atom interferometers seldom achieve their fundamental sensitivity due to the coupling of ambient vibrations. It is the dominant noise source that not only impairs performance but also affects its operability. Ideal compensation of the effects due to vibration noise using a versatile accelerometer, while concurrently enabling miniaturized atom interferometer setups has not been pioneered. Such a compact hybrid quantum sensor will enable reliable operation with an enhanced performance in field applications, paving the way for robust atom interferometry beyond laboratory conditions. A novel optomechanical resonator has been designed, developed and successfully hybridized with an atom interferometer to suppress the effects of vibration noise, and the results are presented in this thesis. The optomechanical resonator’s inertial test mass is simultaneously used to create a continuous intracavity optical lattice to sense its displacement, and a pulsed optical lattice to manipulate the atoms. For the first time, a broadband accelerometer is seamlessly hybridized with an atom interferometer via mechanical resonator mediated coupling of the optical lattices to measure acceleration. This enables elimination of vibration induced measurement ambiguity in our atom interferometer with a well defined mechanical transfer function. Vibration noise correlation is demonstrated up to our prototype atom interferometer’s most sensitive operating mode of T = 6 ms using double Bragg diffraction, ultimately limited by its technical noise. The optomechanical resonator measures acceleration with a sensitivity down to 1.1×10−6 ms−2/ √Hz corresponding to a displacement sensitivity of 8.6 × 10−15 m/ √Hz. Substantial 1/f noise suppression due to the developed optical readout scheme enables a measurement bandwidth spanning from sub-hertz frequencies up to several kilohertz. Multiple versions of the optomechanical resonator with different characteristics were developed and hybridized with our atom interferometer. This paves the way for developing tailored optomechanical resonators for specific inertial sensing applications.

•Jan 1, 2026•0 citations

Fundamental limitations of cavity-assisted atom interferometry

M. Dovale Álvarez, Daniel Brown, A. W. Jones +3 more

Atom interferometers employing optical cavities to enhance the beam splitter pulses promise significant advances in science and technology, notably for future gravitational wave detectors. Long cavities, on the scale of hundreds of meters, have been proposed in experiments aiming to observe gravitational waves with frequencies below 1 Hz, where laser interferometers, such as LIGO, have poor sensitivity. Alternatively, short cavities have also been proposed for enhancing the sensitivity of more portable atom interferometers. We explore the fundamental limitations of two-mirror cavities for atomic beam splitting, and establish upper bounds on the temperature of the atomic ensemble as a function of cavity length and three design parameters: the cavity $g$ factor, the bandwidth, and the optical suppression factor of the first and second order spatial modes. A lower bound to the cavity bandwidth is found which avoids elongation of the interaction time and maximizes power enhancement. An upper limit to cavity length is found for symmetric two-mirror cavities, restricting the practicality of long baseline detectors. For shorter cavities, an upper limit on the beam size was derived from the geometrical stability of the cavity. These findings aim to aid the design of current and future cavity-assisted atom interferometers.

arXiv:1710.02448•Physical Review A•Nov 8, 2017•27 citations

Fundamental Limitations Of Cavity-Assisted Atom Interferometry

D. D. Brown M. Dovale-Álvarez

Atom interferometers employing optical cavities to enhance the beam splitter pulses promise significant advances in science and technology, notably for future gravitational wave detectors. Long cavities, on the scale of hundreds of meters, have been proposed in experiments aiming to observe gravitational waves with frequencies below 1 Hz, where laser interferometers, such as LIGO, have poor sensitivity. Alternatively, short cavities have also been proposed for enhancing the sensitivity of more portable atom interferometers.We explore the fundamental limitations of two-mirror cavities for atomic beam splitting, and establish upper bounds on the temperature of the atomic ensemble as a function of cavity length and three design parameters: the cavity g factor, the bandwidth, and the optical suppression factor of the first and second order spatial modes. A lower bound to the cavity bandwidth is found which avoids elongation of the interaction time and maximizes power enhancement. An upper limit to cavity length is found for symmetric two-mirror cavities, restricting the practicality of long baseline detectors. For shorter cavities, an upper limit on the beam size was derived from the geometrical stability of the cavity. These findings aim to aid the design of current and future cavity-assisted atom interferometers.

•Nov 8, 2017•0 citations

Probing gravity with trapped atoms: the optical lattice atom interferometer

Cristian Daniel Panda

Atom interferometers are quantum mechanical devices sensitive to gravitational and inertial forces, with applications in fundamental physics and inertial sensing in the field. Their performance is currently limited by the interrogation time available to freely falling atoms in Earth’s gravitational field, as well as noise due to mechanical and acoustic vibrations. Our experiment probes gravitational potentials by holding, rather than dropping, atoms. We realize an interrogation time of 20 seconds by suspending the spatially separated atomic wave packets in an optical lattice. This record coherence is enabled by the smooth lattice wave fronts, which are mode-filtered by an optical cavity. This trapped geometry suppresses phase variance due to vibrations by three to four orders of magnitude, overcoming the dominant noise source in atom-interferometric gravimeters. The later part of the talk describes recent progress in characterizing and reducing dephasing of the interferometer. An upgraded optical lattice interferometer experiment is currently being commissioned, with the goal of increased sensitivity to gravity.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•0 citations

Challenges of gravitational wave detection using long-baseline cavity-assisted large momentum transfer atom interferometry

M. Dovale Álvarez, Daniel Brown, A. W. Jones +3 more

Atom interferometers employing optical cavities to enhance the beam splitter pulses promise significant advances in science and technology, notably for future gravitational wave detectors. Long cavities, on the scale of hundreds of meters, have been proposed in experiments aiming to become demonstrators for gravitational wave detection at frequencies below 1 Hz, where laser interferometers, such as LIGO, have poor sensitivity. Our group at the Birmingham Institute of Gravitational Wave Astronomy has explored the fundamental limitations of two-mirror cavities for atomic beam splitting, and established upper bounds on the temperature of the atomic ensemble as a function of cavity length and three design parameters: the cavity $g$-factor, the bandwidth, and the optical suppression factor of the first and second order spatial modes. A lower bound to the cavity bandwidth which avoids elongation of the interaction time and maximizes power enhancement was found. An upper limit to cavity length is also found for symmetric two-mirror cavities. These key limitations impact the feasibility of long-baseline detectors, which suffer from a naturally larger bandwidth and worse optical suppression of higher order optical modes. Our findings will aid the design of current and future experiments using this technology, such as the MIGA experiment in Bordeaux. In the future we aim to fully model the effect that the imperfect optical wavefronts have on the atomic transitions.

•Aug 23, 2018•0 citations
Optical cavities are widely used in atomic physics experiments to control the spatial geometry and spectral properties of atom-light interactions. Recently, an optical lattice generated by the pristine mode of an optical cavity was utilized to hold and extend the quantum coherence of atomic spatial superpositions. Here, we describe an in-vacuum optical cavity designed to enhance the spatial and temporal coherence of optical lattice atom interferometers to one millimeter wavepacket separations and one minute measurement durations. The cavity uses a rigid Zerodur spacer to suppress the negative effects of thermal drift and mechanical-acoustic vibrations on the atomic motional state. The 60 cm-long cavity spacer provides ample optical access for the laser beams and imaging optics necessary for the preparation, quantum control, and read-out of the atomic state, as well as room for various source mass configurations for localized gravitational measurements. An integrated differential pumping structure enables compatibility with ultrahigh-vacuum operation and optical interferometry allows for in-situ vibration monitoring. The performance of the optical cavity is methodically characterized: we measure mirror vibration noise with amplitude below 5 nm/Hz\sqrt{\rm Hz}Hz​ in a wide frequency range of 2 Hz - 100 kHz and a slow 15 MHz thermal drift of the cavity resonance over 47 hours, which can be readily stabilized with an integrated piezo. The optical cavity supports both 852-nm light for Raman transitions and 1064-nm light for the optical lattice, with a free spectral range matched to an integer divisor of the cesium ground-state hyperfine splitting.
We have realized an atom interferometer that probes gravitational potentials by holding, rather than dropping, atoms. Up to one minute of coherence times are realized by suspending the spatially separated atomic wave packets in an optical lattice that is mode-filtered by an optical cavity. This trapped configuration suppresses phase variance due to vibrations by four to five orders of magnitude, overcoming the dominant noise source in atom-interferometric gravimeters. Recent progress in characterizing and reducing interferometer decoherence led to major increases in coherence and precision, paving the way to measurements of dark-energy candidates and probes of the quantum nature of gravity through measuring the gravity of source masses with record precision and spatial resolution.
Quantum sensing using atom interferometry possesses immense potential for application in gravimetry, inertial navigation and for gravitational wave detection, apart from carrying out tests of fundamental physics. Atom interferometry can be used to perform absolute inertial measurements with unprecedented long term stability, unlike classical sensors which are prone to drift and incur calibration errors. However, atom interferometers seldom achieve their fundamental sensitivity due to the coupling of ambient vibrations. It is the dominant noise source that not only impairs performance but also affects its operability. Ideal compensation of the effects due to vibration noise using a versatile accelerometer, while concurrently enabling miniaturized atom interferometer setups has not been pioneered. Such a compact hybrid quantum sensor will enable reliable operation with an enhanced performance in field applications, paving the way for robust atom interferometry beyond laboratory conditions. A novel optomechanical resonator has been designed, developed and successfully hybridized with an atom interferometer to suppress the effects of vibration noise, and the results are presented in this thesis. The optomechanical resonator’s inertial test mass is simultaneously used to create a continuous intracavity optical lattice to sense its displacement, and a pulsed optical lattice to manipulate the atoms. For the first time, a broadband accelerometer is seamlessly hybridized with an atom interferometer via mechanical resonator mediated coupling of the optical lattices to measure acceleration. This enables elimination of vibration induced measurement ambiguity in our atom interferometer with a well defined mechanical transfer function. Vibration noise correlation is demonstrated up to our prototype atom interferometer’s most sensitive operating mode of T = 6 ms using double Bragg diffraction, ultimately limited by its technical noise. The optomechanical resonator measures acceleration with a sensitivity down to 1.1×10−6 ms−2/ √Hz corresponding to a displacement sensitivity of 8.6 × 10−15 m/ √Hz. Substantial 1/f noise suppression due to the developed optical readout scheme enables a measurement bandwidth spanning from sub-hertz frequencies up to several kilohertz. Multiple versions of the optomechanical resonator with different characteristics were developed and hybridized with our atom interferometer. This paves the way for developing tailored optomechanical resonators for specific inertial sensing applications.
Atom interferometers employing optical cavities to enhance the beam splitter pulses promise significant advances in science and technology, notably for future gravitational wave detectors. Long cavities, on the scale of hundreds of meters, have been proposed in experiments aiming to observe gravitational waves with frequencies below 1 Hz, where laser interferometers, such as LIGO, have poor sensitivity. Alternatively, short cavities have also been proposed for enhancing the sensitivity of more portable atom interferometers. We explore the fundamental limitations of two-mirror cavities for atomic beam splitting, and establish upper bounds on the temperature of the atomic ensemble as a function of cavity length and three design parameters: the cavity ggg factor, the bandwidth, and the optical suppression factor of the first and second order spatial modes. A lower bound to the cavity bandwidth is found which avoids elongation of the interaction time and maximizes power enhancement. An upper limit to cavity length is found for symmetric two-mirror cavities, restricting the practicality of long baseline detectors. For shorter cavities, an upper limit on the beam size was derived from the geometrical stability of the cavity. These findings aim to aid the design of current and future cavity-assisted atom interferometers.
Atom interferometers employing optical cavities to enhance the beam splitter pulses promise significant advances in science and technology, notably for future gravitational wave detectors. Long cavities, on the scale of hundreds of meters, have been proposed in experiments aiming to observe gravitational waves with frequencies below 1 Hz, where laser interferometers, such as LIGO, have poor sensitivity. Alternatively, short cavities have also been proposed for enhancing the sensitivity of more portable atom interferometers.We explore the fundamental limitations of two-mirror cavities for atomic beam splitting, and establish upper bounds on the temperature of the atomic ensemble as a function of cavity length and three design parameters: the cavity g factor, the bandwidth, and the optical suppression factor of the first and second order spatial modes. A lower bound to the cavity bandwidth is found which avoids elongation of the interaction time and maximizes power enhancement. An upper limit to cavity length is found for symmetric two-mirror cavities, restricting the practicality of long baseline detectors. For shorter cavities, an upper limit on the beam size was derived from the geometrical stability of the cavity. These findings aim to aid the design of current and future cavity-assisted atom interferometers.
Atom interferometers are quantum mechanical devices sensitive to gravitational and inertial forces, with applications in fundamental physics and inertial sensing in the field. Their performance is currently limited by the interrogation time available to freely falling atoms in Earth’s gravitational field, as well as noise due to mechanical and acoustic vibrations. Our experiment probes gravitational potentials by holding, rather than dropping, atoms. We realize an interrogation time of 20 seconds by suspending the spatially separated atomic wave packets in an optical lattice. This record coherence is enabled by the smooth lattice wave fronts, which are mode-filtered by an optical cavity. This trapped geometry suppresses phase variance due to vibrations by three to four orders of magnitude, overcoming the dominant noise source in atom-interferometric gravimeters. The later part of the talk describes recent progress in characterizing and reducing dephasing of the interferometer. An upgraded optical lattice interferometer experiment is currently being commissioned, with the goal of increased sensitivity to gravity.
Atom interferometers employing optical cavities to enhance the beam splitter pulses promise significant advances in science and technology, notably for future gravitational wave detectors. Long cavities, on the scale of hundreds of meters, have been proposed in experiments aiming to become demonstrators for gravitational wave detection at frequencies below 1 Hz, where laser interferometers, such as LIGO, have poor sensitivity. Our group at the Birmingham Institute of Gravitational Wave Astronomy has explored the fundamental limitations of two-mirror cavities for atomic beam splitting, and established upper bounds on the temperature of the atomic ensemble as a function of cavity length and three design parameters: the cavity ggg-factor, the bandwidth, and the optical suppression factor of the first and second order spatial modes. A lower bound to the cavity bandwidth which avoids elongation of the interaction time and maximizes power enhancement was found. An upper limit to cavity length is also found for symmetric two-mirror cavities. These key limitations impact the feasibility of long-baseline detectors, which suffer from a naturally larger bandwidth and worse optical suppression of higher order optical modes. Our findings will aid the design of current and future experiments using this technology, such as the MIGA experiment in Bordeaux. In the future we aim to fully model the effect that the imperfect optical wavefronts have on the atomic transitions.