Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2611.23968

Analysis of a Homodyne-Like Measurement Scheme Using Photon Counters and Weak Local Oscillator

Arik Avagyan, Emanuel Knill, Scott Glancy

quant-phSubmitted Nov 18, 2026• Announced Nov 19, 2026• 0 citations
arXivHTMLPDF

Abstract

In standard homodyne detection, an unknown optical signal state is combined with a local oscillator (LO) at a beam splitter (BS), and the appropriately integrated intensities at the two outputs of the BS are subtracted to obtain an approximate quadrature measurement. Accurate quadrature measurements require a high-amplitude LO and high-efficiency detectors. By varying the LO phase, the optical state in the mode matching the LO can be reconstructed. In many practical settings, a high-intensity LO is not desirable, which has led to the exploration of homodyne-like measurement schemes that replace photodiodes with photon-counting detectors and use an LO with a low average photon number. In this paper, we investigate what features of the unknown state can be determined by counting the total-photon number in one or both outgoing paths after the BS, keeping the mode of the LO fixed but adjusting its phase and magnitude. We find that it is possible to determine the unknown optical state in the mode matching the LO conditional on the number of photons in the orthogonal modes on the same path. If both the phase and the intensity of the LO can be varied, the statistics of just one of the detectors is sufficient to infer these parameters, but both detectors are required when the LO has a fixed intensity. Our analysis is carried out in the infinite-data limit, assuming access to the full photon-number distribution from one or both detectors.

AI Summary

The paper asks what weak-field homodyne detection can identify when the signal has an unknown multimode structure, the local-oscillator (LO) mode is fixed, and photon-number-resolving detectors count total photons without resolving modes. It considers a nontrivial lossless beam splitter, with either one or both output ports measured and the coherent LO’s phase and possibly magnitude varied. The identifiable object is a two-mode representative $\rho_t=\sum_n\chi_n\otimes|n\rangle\langle n|$: $\operatorname{tr}\chi_n$ gives the probability of $n$ photons in modes orthogonal to the LO, while normalized $\chi_n$ gives the LO-matched state conditional on that number. For states with moment-determinate Husimi functions, one detector suffices when LO amplitudes range over a set of positive measure. With a total-photon cutoff $N$, almost every set of $(N+1)^2$ amplitudes suffices. At fixed nonzero LO magnitude, phase scanning suffices with two detectors, but one detector is generally insufficient beyond the one-photon sector. No finite set of amplitudes suffices without a photon-number bound. The results follow from passive-linear-optics symmetries, Haar twirling and Schur’s lemma, followed by generating-function manipulations, polynomial interpolation, Fourier inversion, and dimension-counting arguments. Normally ordered weighted count-difference moments also determine the LO-matched marginal. The analysis assumes infinite data and access to complete photon-count distributions, finitely many signal modes, and mode-independent detection. It does not establish finite-sample stability or optimal setting counts; mode-dependent loss and reconstruction using multiple LO modes remain open directions.

Little sign of AI-generated textAI use disclosedStrong assumptions
AI was used for researching the relevant literature, finding relevant works to reference and take advantage of in updated proofs and added results, and to improve the language.

Error found: The abstract omits the moment-determinate-Husimi restriction required by the reconstruction proofs, leaving unrestricted reconstruction unestablished. The abstract omits the finite-mode assumption explicitly imposed in the measurement setup. The claimed strong-LO equivalence of ordinary and normally ordered photon-count-difference moments fails already for vacuum signal, whose normalized second moments are respectively one and zero. The Fourier inversion in the fixed-magnitude two-counter proof has a factor-of-two normalization error that does not affect identifiability.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Comments
25 pages

Related papers

Quantum State Characterization Using Measurement Configurations Inspired by Homodyne Detection

Arik Avagyan

In the standard homodyne configuration, an unknown optical state is combined with a local oscillator (LO) on a beam splitter (BS). Good quadrature measurements require a high-amplitude LO and two high-efficiency photodiodes whose signals are subtracted and normalized. By changing the LO phase, it is then possible to infer the optical state in the mode matching the LO. For quantum information processing, the states of interest are in well-separated modes, corresponding to a pulsed configuration with one relevant LO mode per measurement. We theoretically investigate what can be learned about the unknown optical state by counting photons in one or both outgoing paths after the BS, keeping the LO mode fixed but choosing its phase and magnitude. We consider measurement configurations where the BS acts differently on different sets of matching modes. When the BS acts identically on all matching modes it is possible to determine the content of the unknown optical state in the mode matching the LO conditional on each number of photons in the orthogonal modes on the same path. In particular, if both the phase and the intensity of the LO can be varied, then the statistics of just one of the counters is enough to infer these parameters, while in the case of an LO with fixed intensity both detectors are needed to accomplish this. Our results are derived by demonstrating a bijection, or lack thereof, between the probability distributions over the space of outcomes of the counter(s) and certain parameters of the unknown state for different measurement configuration. We report an experiment that was conducted to demonstrate the theory in the case where the BS acts differently depending on the polarization.

arXiv:2305.19397•May 30, 2023•6 citations

Homodyne-like detection scheme based on photon-number-resolving detectors

Alessia Allevi, Matteo Bina, Stefano Olivares +1 more

Homodyne detection is the most effective detection scheme employed in quantum optics to characterize quantum states. It is based on mixing at a beam splitter the signal to be measured with a coherent state, called the “local oscillator,” and on evaluating the difference of the photocurrents of two photodiodes measuring the outputs of the beam splitter. If the local oscillator is much more intense than the field to be measured, the homodyne signal is proportional to the signal-field quadratures. If the local oscillator is less intense, the photodiodes can be replaced with photon-number-resolving detectors, which have a smaller dynamics but can measure the light statistics. The resulting new homodyne-like detector acquires a hybrid nature, being it capable of yielding information on both the particle-like (statistics) and wave-like (phase) properties of light signals. The scheme has been tested in the measurement of the quadratures of coherent states, bracket states and phase-averaged coherent states at different intensities of the local oscillator.

International Journal of Quantum Information•Dec 1, 2017•19 citations

Homodyne statistics

Samuel L. Braunstein

The balanced homodyne detector is the paradigm of phase-sensitive detection schemes in quantum optics. We study the effects of a quantum local oscillator in a coherent state for this detector when it is coupled to a single signal mode. We calculate explicit general expressions for the output statistics of the difference current of this detector (applicable even to non-classical states), and compare them to the statistics of the so-called quadrature-phase amplitude. We show that the naive condition that the number of quanta in the local oscillator be much larger than the number in the signal is not sufficient to ensure that the homodyne detector approximates an ideal detectorof the quadrature-phase amplitude, further, we derive explicit conditions for this approximation to be achieved when the signal is a coherent state or a superposition of coherent states.

Annual Meeting Optical Society of America•Jan 1, 1990•0 citations

Broadband pulsed quadrature measurements with calorimeters

Ezad Shojaee, James R. van Meter, Karl Mayer +2 more

A fundamental problem in quantum optics is to measure a quadrature operator of a mode described by a shape in the time or frequency domain. This can be done by pulsed homodyne detection, in which the signal and a high-amplitude pulsed local oscillator (LO) interfere on a beam splitter whose output ports are monitored by photodetectors. The quadrature value is proportional to the difference between the photodetectors' signals. When the shape of the mode is too broad in frequency, the lack of uniform spectral response of detectors prevents direct application of this technique. We show that pulsed homodyne detection can be generalized to broadband pulsed (BBP) homodyne detection with detectors such as calorimeters that detect total energy instead of total photon number. This generalization has applications in measurements of femtosecond pulses and, speculatively, of Rindler modes. We analyze how the implemented measurement approaches an ideal quadrature measurement with growing LO amplitude, and we prove that the moments of the measurement converge to the moments of the quadrature and that the measurement distributions converge weakly.

arXiv:2503.00188•Physical Review A•Dec 8, 2025•2 citations

Statistics of difference events in homodyne detection

W. Vogel, Jens Grabow

The statistics of the difference events in a balanced homodyne-detection scheme is studied without using the standard assumption of a strong, classical local oscillator. Starting from the quantum theory of photon counting, we derive the probability distribution for the difference events in the two detection channels. In the limit of the local oscillator being strong compared with the signal, the difference-number statistics tends to the statistics of the electric-field strength of the signal field. For weak signals, this limit may be obtained already far from a classical behavior of the local oscillator. While changing the local oscillator intensity, a transition of the observable concerning the signal field occurs from the photon-number difference towards the electric-field strength. Such a measurement scheme renders it possible to observe the quantum features of a coherent state or a single-photon state from the point of view of the field-strength statistics, a picture which is closely related to classical optics. The possibility to get some insight in the statistical properties of the phase difference of two microscopic fields is discussed.

Physical Review A•May 1, 1993•99 citations

Kramers-Kronig detection in the quantum regime

Thomas Pousset, Maxime Federico, Romain Alléaume +1 more

We investigate the quantization of Kramers-Kronig detection technique initially developed for classical optical communications. It consists in mixing the unknown field with a strong monochromatic local oscillator on an unbalanced beam splitter. A single output of the beam splitter undergoes a direct detection of the optical intensity by means of a single photodiode. When the measured output verifies signal processing constraints, namely, the minimal phase and the single-sideband constraints, Kramers-Kronig detection reconstructs the phase of the signal from the intensity measurements via a digitally computed Hilbert transform. The local oscillator being known, Kramers-Kronig detection allows for reconstructing the quadratures of the unknown field. We show that this result holds in the quantum regime up to first order in the local oscillator amplitude and thus that Kramers-Kronig detection acts as a coherent detection able to measure both quadratures, making it a Gaussian measurement similar to double homodyne detection. We also study in detail the phase information measured by Kramers-Kronig detection for bosonic coherent states, monomode pure states, and mixed states. Finally, we propose and investigate a spectral tomography protocol for single-photon states that is inspired by Kramers-Kronig detection and relies on a spectral engineering of the single photon.

arXiv:2407.20827•Physical Review Research•Dec 12, 2025•2 citations
In standard homodyne detection, an unknown optical signal state is combined with a local oscillator (LO) at a beam splitter (BS), and the appropriately integrated intensities at the two outputs of the BS are subtracted to obtain an approximate quadrature measurement. Accurate quadrature measurements require a high-amplitude LO and high-efficiency detectors. By varying the LO phase, the optical state in the mode matching the LO can be reconstructed. In many practical settings, a high-intensity LO is not desirable, which has led to the exploration of homodyne-like measurement schemes that replace photodiodes with photon-counting detectors and use an LO with a low average photon number. In this paper, we investigate what features of the unknown state can be determined by counting the total-photon number in one or both outgoing paths after the BS, keeping the mode of the LO fixed but adjusting its phase and magnitude. We find that it is possible to determine the unknown optical state in the mode matching the LO conditional on the number of photons in the orthogonal modes on the same path. If both the phase and the intensity of the LO can be varied, the statistics of just one of the detectors is sufficient to infer these parameters, but both detectors are required when the LO has a fixed intensity. Our analysis is carried out in the infinite-data limit, assuming access to the full photon-number distribution from one or both detectors.
The paper asks what weak-field homodyne detection can identify when the signal has an unknown multimode structure, the local-oscillator (LO) mode is fixed, and photon-number-resolving detectors count total photons without resolving modes. It considers a nontrivial lossless beam splitter, with either one or both output ports measured and the coherent LO’s phase and possibly magnitude varied.
The identifiable object is a two-mode representative ρt=∑nχn⊗∣n⟩⟨n∣\rho_t=\sum_n\chi_n\otimes|n\rangle\langle n|ρt​=∑n​χn​⊗∣n⟩⟨n∣: tr⁡χn\operatorname{tr}\chi_ntrχn​ gives the probability of nnn photons in modes orthogonal to the LO, while normalized χn\chi_nχn​ gives the LO-matched state conditional on that number. For states with moment-determinate Husimi functions, one detector suffices when LO amplitudes range over a set of positive measure. With a total-photon cutoff NNN, almost every set of (N+1)2(N+1)^2(N+1)2 amplitudes suffices. At fixed nonzero LO magnitude, phase scanning suffices with two detectors, but one detector is generally insufficient beyond the one-photon sector. No finite set of amplitudes suffices without a photon-number bound.
The results follow from passive-linear-optics symmetries, Haar twirling and Schur’s lemma, followed by generating-function manipulations, polynomial interpolation, Fourier inversion, and dimension-counting arguments. Normally ordered weighted count-difference moments also determine the LO-matched marginal.
The analysis assumes infinite data and access to complete photon-count distributions, finitely many signal modes, and mode-independent detection. It does not establish finite-sample stability or optimal setting counts; mode-dependent loss and reconstruction using multiple LO modes remain open directions.
In the standard homodyne configuration, an unknown optical state is combined with a local oscillator (LO) on a beam splitter (BS). Good quadrature measurements require a high-amplitude LO and two high-efficiency photodiodes whose signals are subtracted and normalized. By changing the LO phase, it is then possible to infer the optical state in the mode matching the LO. For quantum information processing, the states of interest are in well-separated modes, corresponding to a pulsed configuration with one relevant LO mode per measurement. We theoretically investigate what can be learned about the unknown optical state by counting photons in one or both outgoing paths after the BS, keeping the LO mode fixed but choosing its phase and magnitude. We consider measurement configurations where the BS acts differently on different sets of matching modes. When the BS acts identically on all matching modes it is possible to determine the content of the unknown optical state in the mode matching the LO conditional on each number of photons in the orthogonal modes on the same path. In particular, if both the phase and the intensity of the LO can be varied, then the statistics of just one of the counters is enough to infer these parameters, while in the case of an LO with fixed intensity both detectors are needed to accomplish this. Our results are derived by demonstrating a bijection, or lack thereof, between the probability distributions over the space of outcomes of the counter(s) and certain parameters of the unknown state for different measurement configuration. We report an experiment that was conducted to demonstrate the theory in the case where the BS acts differently depending on the polarization.
Homodyne detection is the most effective detection scheme employed in quantum optics to characterize quantum states. It is based on mixing at a beam splitter the signal to be measured with a coherent state, called the “local oscillator,” and on evaluating the difference of the photocurrents of two photodiodes measuring the outputs of the beam splitter. If the local oscillator is much more intense than the field to be measured, the homodyne signal is proportional to the signal-field quadratures. If the local oscillator is less intense, the photodiodes can be replaced with photon-number-resolving detectors, which have a smaller dynamics but can measure the light statistics. The resulting new homodyne-like detector acquires a hybrid nature, being it capable of yielding information on both the particle-like (statistics) and wave-like (phase) properties of light signals. The scheme has been tested in the measurement of the quadratures of coherent states, bracket states and phase-averaged coherent states at different intensities of the local oscillator.
The balanced homodyne detector is the paradigm of phase-sensitive detection schemes in quantum optics. We study the effects of a quantum local oscillator in a coherent state for this detector when it is coupled to a single signal mode. We calculate explicit general expressions for the output statistics of the difference current of this detector (applicable even to non-classical states), and compare them to the statistics of the so-called quadrature-phase amplitude. We show that the naive condition that the number of quanta in the local oscillator be much larger than the number in the signal is not sufficient to ensure that the homodyne detector approximates an ideal detectorof the quadrature-phase amplitude, further, we derive explicit conditions for this approximation to be achieved when the signal is a coherent state or a superposition of coherent states.
A fundamental problem in quantum optics is to measure a quadrature operator of a mode described by a shape in the time or frequency domain. This can be done by pulsed homodyne detection, in which the signal and a high-amplitude pulsed local oscillator (LO) interfere on a beam splitter whose output ports are monitored by photodetectors. The quadrature value is proportional to the difference between the photodetectors' signals. When the shape of the mode is too broad in frequency, the lack of uniform spectral response of detectors prevents direct application of this technique. We show that pulsed homodyne detection can be generalized to broadband pulsed (BBP) homodyne detection with detectors such as calorimeters that detect total energy instead of total photon number. This generalization has applications in measurements of femtosecond pulses and, speculatively, of Rindler modes. We analyze how the implemented measurement approaches an ideal quadrature measurement with growing LO amplitude, and we prove that the moments of the measurement converge to the moments of the quadrature and that the measurement distributions converge weakly.
The statistics of the difference events in a balanced homodyne-detection scheme is studied without using the standard assumption of a strong, classical local oscillator. Starting from the quantum theory of photon counting, we derive the probability distribution for the difference events in the two detection channels. In the limit of the local oscillator being strong compared with the signal, the difference-number statistics tends to the statistics of the electric-field strength of the signal field. For weak signals, this limit may be obtained already far from a classical behavior of the local oscillator. While changing the local oscillator intensity, a transition of the observable concerning the signal field occurs from the photon-number difference towards the electric-field strength. Such a measurement scheme renders it possible to observe the quantum features of a coherent state or a single-photon state from the point of view of the field-strength statistics, a picture which is closely related to classical optics. The possibility to get some insight in the statistical properties of the phase difference of two microscopic fields is discussed.
We investigate the quantization of Kramers-Kronig detection technique initially developed for classical optical communications. It consists in mixing the unknown field with a strong monochromatic local oscillator on an unbalanced beam splitter. A single output of the beam splitter undergoes a direct detection of the optical intensity by means of a single photodiode. When the measured output verifies signal processing constraints, namely, the minimal phase and the single-sideband constraints, Kramers-Kronig detection reconstructs the phase of the signal from the intensity measurements via a digitally computed Hilbert transform. The local oscillator being known, Kramers-Kronig detection allows for reconstructing the quadratures of the unknown field. We show that this result holds in the quantum regime up to first order in the local oscillator amplitude and thus that Kramers-Kronig detection acts as a coherent detection able to measure both quadratures, making it a Gaussian measurement similar to double homodyne detection. We also study in detail the phase information measured by Kramers-Kronig detection for bosonic coherent states, monomode pure states, and mixed states. Finally, we propose and investigate a spectral tomography protocol for single-photon states that is inspired by Kramers-Kronig detection and relies on a spectral engineering of the single photon.