Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2611.21360

Sequential strategy for depolarizing strength estimation

Yasir Mehmood, Enrico Trombetti, Marco Pezzutto, Stefano Gherardini

quant-phSubmitted Nov 16, 2026• Announced Nov 17, 2026• 0 citations
arXivHTMLPDF

Abstract

We study the advantages of applying a sequential strategy for enhancing the precision in estimating the strength $p$ of a depolarizing channel, using qudit and two-qubit probes. The sequential strategy requires that the same depolarizing channel is repeatedly applied $M$ times to the quantum probe. From the analysis of the probe's output state, both the quantum Fisher information (QFI) and its regularization RQFI, given from multiplication by $p$, are analyzed. We determine that in the limit of $p \to 0$, the QFI is {\it linearly amplified} with the number of channel repetitions. Instead, in the weak-noise regime, the QFI is maximized at a finite value of $M$. Then, the RQFI decreases more quickly with $p$ as $M$ increases. In particular, for two-qubit probes, the RQFI decreases with the depolarization strength proportionally to the amount of correlation between the qubits. The greater the number of channel repetitions, the wider the range of $p$ for which the initial state of the probe that allows for the maximization of the QFI is a separable state. We also show that a single qubit probe undergoing a sequential encoding protocol outperforms the optimal two-qubit single-round QFI for $M>3$ in the weak-noise regime.

AI Summary

The paper studies estimation of the strength $p$ of a depolarizing channel when the same probe undergoes $M$ successive channel applications before measurement. It considers pure single-qudit probes, arbitrary single-qubit inputs, and two-qubit probes exposed to independent local depolarization. Precision is characterized by the quantum Fisher information (QFI) $J$ and its regularization $\mathcal J=pJ$. Closed-form output states and QFI expressions are derived using symmetric logarithmic derivatives and spectral decompositions, with numerical checks. For a pure $d$-dimensional probe, $J=M(d-1)/p+O(1)$ as $p\to0$. At fixed nonzero noise, repeated depolarization eventually reduces sensitivity, producing a finite optimal repetition count $M^*$ that scales approximately as $1/p$ at weak noise. For arbitrary single-qubit inputs, the QFI depends only on initial purity and is maximized by pure states. For two-qubit inputs $\sqrt\mu|00\rangle+\sqrt{1-\mu}|11\rangle$, the weak-noise result is $J=M(4-2P)/p+O(1)$, where $P$ is the reduced-state purity. Optimization selects either maximally entangled or separable inputs; increasing $M$ narrows the noise range favoring entanglement. The paper also analyzes how the initial slope of $\mathcal J$ depends on correlations and repetitions. A sequential single-qubit probe exceeds the cited optimal two-qubit single-round QFI for $M\ge4$ at sufficiently weak noise. This comparison explicitly uses unequal channel-use resources, rather than establishing a resource-matched advantage. The study is theoretical; extensions beyond two probes, experimental demonstrations, noisy circuits, and distributed sensing remain future directions.

Some signs of AI-generated textIncrementalUnclear noveltyPossible error

Error found: The general channel equation disagrees beyond first order in p with the independent local depolarizing channels used in the two-qubit calculations and is not positive over its stated parameter range. The weak-noise appendix's SLD expansion gives the wrong constant term, although its resulting leading-order QFI coefficient is correct. For a maximally entangled two-qubit input and one encoding round, the RQFI slope at p=0 is zero, contradicting the claim that it is positive for every listed input.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

DOI
10.48550/arxiv.2611.21360
Comments
18 pages, 12 figures. Comments and feedback are welcome

Related papers

Optimal noisy sequential multiparameter quantum sensing

Andrew Tanggara, Lorcán O Conlon, Alexey V. Gorshkov +1 more

The most general strategy for estimating parameters of a quantum channel is to probe the channel many times sequentially with the help of coherent ancillary systems. However, finding the strategy that minimizes the mean-squared error (MSE) is a notoriously hard problem, requiring optimization over the initial probe state, intermediate evolutions, final measurement, and classical postprocessing. In this work, we study how the minimum attainable MSE can be bounded from below in this setting. We propose a lower bound for the MSE of any physically implementable sequential sensing strategy that applies to estimating parameters of any physical quantum evolution, including quantum channels probed over multiple time steps under temporally correlated noise and general temporally correlated quantum processes. We show that this lower bound can be formulated as a semidefinite program (SDP). Our bound generalizes the Nagaoka-Hayashi lower bound (that applies to parameter estimation tasks with separable measurements) to the regime where the quantum channel can be accessed sequentially multiple times. For regular finite-dimensional single-parameter sequential estimation tasks admitting an optimal strategy, we show that our SDP bound is tight and provide a procedure to obtain a locally optimal strategy from the SDP optimizer. Using our optimization bound, we compute the MSE lower bound and derive new protocols for several other physically motivated problems including error-corrected quantum sensing under an unknown correlated noise model, multiparameter estimation, and estimation with qudit systems.

quant-pharXiv:2609.30398•Sep 28, 2026•2 citations

Enhanced Noisy Depolarizing Channel Parameter Estimation

David C. Collins, Jaimie Stephens

We consider protocols for estimating the parameter which characterizes a single qubit depolarizing channel, with the goal of attaining the most accurate estimate per channel use. The accuracy of any quantum estimation protocol will be quantified via the quantum Fisher information (QFI) since the Cramer-Rao bound implies thata larger QFI yields a smaller lower bound on the possible variance in any estimate of the parameter. Within this framework, the choice of input state prior to channel invocation affects estimation accuracy. The known optimal estimation scheme uses pairs of maximally entangled pure input states, giving a gain over any protocol using unentangled input states. Entangling more than two qubits initially in apure state provides no further gain in the QFI per channel use. We ask if,when the available input states are not pure,these gains persist and if correlating more than two qubits is advantageous. We present a protocol using input states correlated over any number of qubits and compare this to an independent channel useprotocol using uncorrelated mixed states. We show that the correlated state protocol yields gains in the QFI per channel use for certain physically reasonable parameter ranges. We show that, unlike the pure state case, using more than two correlated qubits can be advantageous and we show that, as the initial qubit states become highly mixed, adding additional correlated qubits can provide substantial gains in estimation accuracy. We show that for two qubits, such gainsare attained even when the state prior to channel invocationare separable. Thedepolarizing channelmaps a qubit as

•Jan 1, 2013•0 citations

Depolarizing-channel parameter estimation using noisy initial states

David C. Collins, Jaimie Stephens

We consider estimating the parameter associated with the qubit depolarizing channel when the available initial states that might be employed are mixed. We use quantum Fisher information as a measure of the accuracy of estimation to compare protocols which use collections of qubits in product states to one in which the qubits are in a correlated state. We show that, for certain parameter values and initial states, the correlated-state protocol can yield a greater accuracy per channel invocation than the product-state protocols. We show that, for some parameters and initial states, using more than two qubits and channel invocations is advantageous. These results stand in contrast to the known optimal case that uses pure initial states and a single channel invocation on a pair of entangled qubits.

arXiv:1506.06147•Physical Review A•Sep 25, 2015•23 citations

Scaling-optimal purification of noisy qubit unitary channels

Ryotaro Niwa, Satoshi Yoshida, Koki Ono +5 more

We consider the problem of purifying noisy qubit unitary channels. Given the ability to apply an unknown qubit unitary channel followed by depolarizing noise, we aim to construct a superchannel that purifies the noisy unitary back to the original unknown unitary. We first provide numerical evidence that sequential strategies can strictly outperform parallel strategies when the number of channel uses is finite, highlighting the fundamental distinction from state purification. We then provide a concrete $\mathrm{U}(2)$-covariant parallel protocol based on a novel entanglement-assisted quantum error-correcting code that suppresses the first-order noise strength as $O(1/n)$ with $n$ channel uses and show this scaling is asymptotically optimal in the low-noise regime, even when sequential strategies are allowed.

quant-pharXiv:2606.12394•Jun 11, 2026•4 citations

Probing correlation in quantum arrays

Theodore J. Yoder, Michael R. Frey

We consider the problem of identifying the degree of correlation θ in the depolarization rates of an array of qubits, such as might be found in a holding register in a quantum information processing architecture. We treat this as a problem in quantum channel identification and use the quantum Fisher information about θ in the channel output to compare different candidate probe states. We consider channel probes in general pure N-qubit cat states and find that partial entanglement is always suboptimal; the best cat probe state is either separable or maximally entangled, and we lay out for any given depolarizing rate p and correlation θ, the (p, θ)-regions for which separable and maximally entangled probes each yield the most information. In the case of very large qubit arrays, we find that the quantum Fisher information obtained about θ using any pure cat probe state is asymptotically independent of the state and identically equal to the information available about a classical coin's bias from a single coin toss. Finally, we turn our attention to arrays of N qudits (with common dimension D) that are depolarizing with some correlation θ. We consider both separable and maximally entangled cat probe states and find and compare their quantum Fisher informations in both the large N and large D regimes.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 1, 2012•1 citation

Asymptotic Theory of Quantum Channel Estimation

Sisi Zhou, Liang Jiang

The quantum Fisher information (QFI), as a function of quantum states, measures the amount of information that a quantum state carries about an unknown parameter.The (entanglement-assisted) QFI of a quantum channel is defined to be the maximum QFI of the output state assuming an entangled input state over a single probe and an ancilla.In quantum metrology, people are interested in calculating the QFI of N identical copies of a quantum channel when N → ∞, which is called the asymptotic QFI.Over the years, researchers found various types of upper bounds of the asymptotic QFI, but they were proven achievable only in several specific situations.It was known that the asymptotic QFI of an arbitrary quantum channel grows either linearly or quadratically with N .Here we show that a simple criterion can determine whether the scaling is linear or quadratic.In both cases, the asymptotic QFI and a quantum error correction protocol to achieve it are computable via a semidefinite program.When the scaling is quadratic, the Heisenberg limit, a feature of noiseless quantum channels, is recovered.When the scaling is linear, we show that the asymptotic QFI is still in general larger than N times the single-channel QFI and, furthermore, that sequential estimation strategies provide no advantage over parallel ones.

arXiv:2003.10559•PRX Quantum•Mar 16, 2021•111 citations
We study the advantages of applying a sequential strategy for enhancing the precision in estimating the strength ppp of a depolarizing channel, using qudit and two-qubit probes. The sequential strategy requires that the same depolarizing channel is repeatedly applied MMM times to the quantum probe. From the analysis of the probe's output state, both the quantum Fisher information (QFI) and its regularization RQFI, given from multiplication by ppp, are analyzed. We determine that in the limit of p→0p \to 0p→0, the QFI is {\it linearly amplified} with the number of channel repetitions. Instead, in the weak-noise regime, the QFI is maximized at a finite value of MMM. Then, the RQFI decreases more quickly with ppp as MMM increases. In particular, for two-qubit probes, the RQFI decreases with the depolarization strength proportionally to the amount of correlation between the qubits. The greater the number of channel repetitions, the wider the range of ppp for which the initial state of the probe that allows for the maximization of the QFI is a separable state. We also show that a single qubit probe undergoing a sequential encoding protocol outperforms the optimal two-qubit single-round QFI for M>3M>3M>3 in the weak-noise regime.
The paper studies estimation of the strength ppp of a depolarizing channel when the same probe undergoes MMM successive channel applications before measurement. It considers pure single-qudit probes, arbitrary single-qubit inputs, and two-qubit probes exposed to independent local depolarization. Precision is characterized by the quantum Fisher information (QFI) JJJ and its regularization J=pJ\mathcal J=pJJ=pJ.
Closed-form output states and QFI expressions are derived using symmetric logarithmic derivatives and spectral decompositions, with numerical checks. For a pure ddd-dimensional probe, J=M(d−1)/p+O(1)J=M(d-1)/p+O(1)J=M(d−1)/p+O(1) as p→0p\to0p→0. At fixed nonzero noise, repeated depolarization eventually reduces sensitivity, producing a finite optimal repetition count M∗M^*M∗ that scales approximately as 1/p1/p1/p at weak noise. For arbitrary single-qubit inputs, the QFI depends only on initial purity and is maximized by pure states.
For two-qubit inputs μ∣00⟩+1−μ∣11⟩\sqrt\mu|00\rangle+\sqrt{1-\mu}|11\rangleμ​∣00⟩+1−μ​∣11⟩, the weak-noise result is J=M(4−2P)/p+O(1)J=M(4-2P)/p+O(1)J=M(4−2P)/p+O(1), where PPP is the reduced-state purity. Optimization selects either maximally entangled or separable inputs; increasing MMM narrows the noise range favoring entanglement. The paper also analyzes how the initial slope of J\mathcal JJ depends on correlations and repetitions.
A sequential single-qubit probe exceeds the cited optimal two-qubit single-round QFI for M≥4M\ge4M≥4 at sufficiently weak noise. This comparison explicitly uses unequal channel-use resources, rather than establishing a resource-matched advantage. The study is theoretical; extensions beyond two probes, experimental demonstrations, noisy circuits, and distributed sensing remain future directions.
The most general strategy for estimating parameters of a quantum channel is to probe the channel many times sequentially with the help of coherent ancillary systems. However, finding the strategy that minimizes the mean-squared error (MSE) is a notoriously hard problem, requiring optimization over the initial probe state, intermediate evolutions, final measurement, and classical postprocessing. In this work, we study how the minimum attainable MSE can be bounded from below in this setting. We propose a lower bound for the MSE of any physically implementable sequential sensing strategy that applies to estimating parameters of any physical quantum evolution, including quantum channels probed over multiple time steps under temporally correlated noise and general temporally correlated quantum processes. We show that this lower bound can be formulated as a semidefinite program (SDP). Our bound generalizes the Nagaoka-Hayashi lower bound (that applies to parameter estimation tasks with separable measurements) to the regime where the quantum channel can be accessed sequentially multiple times. For regular finite-dimensional single-parameter sequential estimation tasks admitting an optimal strategy, we show that our SDP bound is tight and provide a procedure to obtain a locally optimal strategy from the SDP optimizer. Using our optimization bound, we compute the MSE lower bound and derive new protocols for several other physically motivated problems including error-corrected quantum sensing under an unknown correlated noise model, multiparameter estimation, and estimation with qudit systems.
We consider protocols for estimating the parameter which characterizes a single qubit depolarizing channel, with the goal of attaining the most accurate estimate per channel use. The accuracy of any quantum estimation protocol will be quantified via the quantum Fisher information (QFI) since the Cramer-Rao bound implies thata larger QFI yields a smaller lower bound on the possible variance in any estimate of the parameter. Within this framework, the choice of input state prior to channel invocation affects estimation accuracy. The known optimal estimation scheme uses pairs of maximally entangled pure input states, giving a gain over any protocol using unentangled input states. Entangling more than two qubits initially in apure state provides no further gain in the QFI per channel use. We ask if,when the available input states are not pure,these gains persist and if correlating more than two qubits is advantageous. We present a protocol using input states correlated over any number of qubits and compare this to an independent channel useprotocol using uncorrelated mixed states. We show that the correlated state protocol yields gains in the QFI per channel use for certain physically reasonable parameter ranges. We show that, unlike the pure state case, using more than two correlated qubits can be advantageous and we show that, as the initial qubit states become highly mixed, adding additional correlated qubits can provide substantial gains in estimation accuracy. We show that for two qubits, such gainsare attained even when the state prior to channel invocationare separable. Thedepolarizing channelmaps a qubit as
We consider estimating the parameter associated with the qubit depolarizing channel when the available initial states that might be employed are mixed. We use quantum Fisher information as a measure of the accuracy of estimation to compare protocols which use collections of qubits in product states to one in which the qubits are in a correlated state. We show that, for certain parameter values and initial states, the correlated-state protocol can yield a greater accuracy per channel invocation than the product-state protocols. We show that, for some parameters and initial states, using more than two qubits and channel invocations is advantageous. These results stand in contrast to the known optimal case that uses pure initial states and a single channel invocation on a pair of entangled qubits.
We consider the problem of purifying noisy qubit unitary channels. Given the ability to apply an unknown qubit unitary channel followed by depolarizing noise, we aim to construct a superchannel that purifies the noisy unitary back to the original unknown unitary. We first provide numerical evidence that sequential strategies can strictly outperform parallel strategies when the number of channel uses is finite, highlighting the fundamental distinction from state purification. We then provide a concrete U(2)\mathrm{U}(2)U(2)-covariant parallel protocol based on a novel entanglement-assisted quantum error-correcting code that suppresses the first-order noise strength as O(1/n)O(1/n)O(1/n) with nnn channel uses and show this scaling is asymptotically optimal in the low-noise regime, even when sequential strategies are allowed.
We consider the problem of identifying the degree of correlation θ in the depolarization rates of an array of qubits, such as might be found in a holding register in a quantum information processing architecture. We treat this as a problem in quantum channel identification and use the quantum Fisher information about θ in the channel output to compare different candidate probe states. We consider channel probes in general pure N-qubit cat states and find that partial entanglement is always suboptimal; the best cat probe state is either separable or maximally entangled, and we lay out for any given depolarizing rate p and correlation θ, the (p, θ)-regions for which separable and maximally entangled probes each yield the most information. In the case of very large qubit arrays, we find that the quantum Fisher information obtained about θ using any pure cat probe state is asymptotically independent of the state and identically equal to the information available about a classical coin's bias from a single coin toss. Finally, we turn our attention to arrays of N qudits (with common dimension D) that are depolarizing with some correlation θ. We consider both separable and maximally entangled cat probe states and find and compare their quantum Fisher informations in both the large N and large D regimes.
The quantum Fisher information (QFI), as a function of quantum states, measures the amount of information that a quantum state carries about an unknown parameter.The (entanglement-assisted) QFI of a quantum channel is defined to be the maximum QFI of the output state assuming an entangled input state over a single probe and an ancilla.In quantum metrology, people are interested in calculating the QFI of N identical copies of a quantum channel when N → ∞, which is called the asymptotic QFI.Over the years, researchers found various types of upper bounds of the asymptotic QFI, but they were proven achievable only in several specific situations.It was known that the asymptotic QFI of an arbitrary quantum channel grows either linearly or quadratically with N .Here we show that a simple criterion can determine whether the scaling is linear or quadratic.In both cases, the asymptotic QFI and a quantum error correction protocol to achieve it are computable via a semidefinite program.When the scaling is quadratic, the Heisenberg limit, a feature of noiseless quantum channels, is recovered.When the scaling is linear, we show that the asymptotic QFI is still in general larger than N times the single-channel QFI and, furthermore, that sequential estimation strategies provide no advantage over parallel ones.