Abstract
We report the use of a single trapped-ion motional mode as a probe of mechanical vibrations of the Paul trap structure. By exciting vibrations of the trap using an ultrasonic transducer mounted outside the vacuum chamber and probing the ion motion through motional sideband interactions, we observe a clear resonance response of the axial mode. We further demonstrate detection of trap vibrations with amplitudes as low as 0.6 picometers. These measurements show direct coupling between macroscopic mechanical motion and trapped-ion dynamics, providing a route toward vibration sensing using quantum control of motional states.
AI Summary
Can mechanical vibrations transmitted through a vacuum chamber measurably drive trapped-ion motion? This experiment uses a single $^{171}\mathrm{Yb}^+$ ion as a probe, with an ultrasonic piezoelectric transducer attached outside the chamber and motional-sideband measurements providing readout. The ion is cooled near its motional ground state before mechanical excitation. Frequency scans reveal resonant responses near the axial mode at $0.356284(8)$ MHz and both radial modes near $1.12$ and $1.36$ MHz. Subsequent measurements focus on the axial mode. Blue-sideband Rabi oscillations are used to reconstruct phonon populations: unconstrained population fits agree with Poisson-distribution fits, while the mean phonon number grows quadratically with drive duration, consistent with coherent displacement rather than heating alone. A driven-oscillator Lindblad model incorporates independently measured heating, $\Gamma=19(1)\,\mathrm{s}^{-1}$, and an estimated additional dephasing rate $\gamma<2\,\mathrm{s}^{-1}$. Fitting the weakest-drive data gives an inferred trap-center vibration amplitude of $0.6(1)$ pm. This amplitude is inferred from the ion response under the moving-potential model, rather than measured independently; its quoted uncertainty is dominated by the Fock-state cutoff used in population reconstruction. Radial-mode frequency fluctuations prevent further characterization of those modes, and heating appreciably alters the populations for the longest weak drives. The paper also notes that the applied mechanical excitation is intentionally strong compared with typical vibration-isolated operation. Mechanical mode-frequency calibration and stabilization are proposed applications, but are not demonstrated.
Central claim may not hold: The paper attributes transducer-correlated ion excitation to mechanical vibration without reporting controls that distinguish it from electrical pickup, which could also produce resonant coherent displacement. The reported 0.6(1) pm mechanical amplitude is conditional on the moving-trap interpretation of the measured force, rather than an independently established mechanical displacement.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- DOI
- 10.48550/arxiv.2611.20610
- Comments
- 6 pages, 4 figures