Fast, non-destructive qubit readout is essential for repeated sampling, mid-circuit measurement, and fault-tolerant neutral-atom quantum processing, but camera-based fluorescence detection introduces electronic latency beyond fluorescence-collection time. We propose coherent readout of the state-dependent resonant fluorescence using balanced homodyne detection with photodiodes. An analytic model quantifies the effect of atomic motion on the time-integrated quadrature signal and noise, showing that harmonic motion causes phase averaging while photon recoils produce trajectory-dependent signal fluctuations; the competition between signal accumulation and motion-induced decoherence sets an optimal detection time. Three-dimensional Monte Carlo simulations validate the model and predict state-detection fidelities exceeding 99% within 100 $μ\mathrm{s}$ for experimentally realistic parameters. These results establish the readout conditions and physical constraints for rapid coherent fluorescence readout of neutral-atom qubits.
Fast, non-destructive qubit readout is essential for repeated sampling, mid-circuit measurement, and fault-tolerant neutral-atom quantum processing, but camera-based fluorescence detection introduces electronic latency beyond fluorescence-collection time. We propose coherent readout of the state-dependent resonant fluorescence using balanced homodyne detection with photodiodes. An analytic model quantifies the effect of atomic motion on the time-integrated quadrature signal and noise, showing that harmonic motion causes phase averaging while photon recoils produce trajectory-dependent signal fluctuations; the competition between signal accumulation and motion-induced decoherence sets an optimal detection time. Three-dimensional Monte Carlo simulations validate the model and predict state-detection fidelities exceeding 99% within 100 μs for experimentally realistic parameters. These results establish the readout conditions and physical constraints for rapid coherent fluorescence readout of neutral-atom qubits.
We measure phase-dependent fluorescence spectra for an elementary system: long-lived coherently driven two-level atoms in an atomic beam. Phase-dependent fluorescence spectra measure quadrature noise in the atomic radiation field. These noise spectra are obtained using a homodyne detection scheme that suppresses excess noise by subtracting signals from two identically prepared atomic samples. Noise spectra are obtained for atomic radiation which is in phase $(0\ifmmode^\circ\else\textdegree\fi{})$ and out of phase $(90\ifmmode^\circ\else\textdegree\fi{})$ with a resonant driving field, as well as $\ifmmode\pm\else\textpm\fi{}45\ifmmode^\circ\else\textdegree\fi{}$ out of phase with an off-resonant driving field. The measured phase-dependent fluorescence spectra are much richer than ordinary fluorescence spectra, and exhibit many novel features. Particularly interesting are phase-dependent noise spectra for off-resonant excitation. These strikingly exhibit direct manifestations of time ordering, which appear as large differences between the measured $45\ifmmode^\circ\else\textdegree\fi{}$ and $\ensuremath{-}45\ifmmode^\circ\else\textdegree\fi{}$ quadrature noise spectra. The measured noise spectra are in excellent agreement in magnitude and shape with the results of a quantum treatment using no free parameters.
Neutral-atom arrays have rapidly advanced to support thousands of qubits and execute high-fidelity logical operations. However, these processors remain severely throttled by their slowest fundamental operation: nondestructive qubit measurement, which requires milliseconds and fundamentally limits the system's clock rate. This bottleneck arises from both an inherent photon-budget dilemma---sufficient fluorescence for reliable state discrimination must be collected without excessive heating or loss---and frame-based imaging, which imposes one common exposure and decision latency on intrinsically independent, site-local measurements. Here, we overcome these limitations with a fast, nondestructive readout architecture based on real-time, site-resolved adaptive protection. By integrating continuous photon counting with a dynamic feedforward framework, we decode qubit states with sub-microsecond latency and instantly shield atoms from redundant scattering. Demonstrated in parallel across a 100-qubit reconfigurable atom array, with adaptive protection on a 25-site subarray, this dynamic decision protocol reduces the average probe time to just 15μs. Model-free benchmarking yields a discrimination infidelity of 4.1×10−5 and an atom loss of 2.1×10−4, simultaneously setting new performance records for atom arrays. Exploiting this capability, we operate repeated quantum circuits at an unprecedented 1.7 kHz clock rate with atoms reused over 120 consecutive rounds---nearly sevenfold higher than the previous record---and enter the sub-millisecond cycle regime for the first time. By removing nondestructive readout as the dominant cycle-time bottleneck, this work unlocks high-clock-rate mid-circuit syndrome extraction, paving the way for high-throughput, fault-tolerant quantum computation.
This thesis describes experimental demonstrations of high-fidelity readout of trapped ion quantum bits ("qubits") for quantum information processing. We present direct single-shot measurement of an "optical" qubit stored in a single calcium-40 ion by the process of resonance fluorescence with a fidelity of 99.991(1)% (surpassing the level necessary for fault-tolerant quantum computation). A time-resolved maximum likelihood method is used to discriminate efficiently between the two qubit states based on photon-counting information, even in the presence of qubit decay from one state to the other. It also screens out errors due to cosmic ray events in the detector, a phenomenon investigated in this work. An adaptive method allows the 99.99% level to be reached in 145us average detection time. The readout fidelity is asymmetric: 99.9998% is possible for the "bright" qubit state, while retaining 99.98% for the "dark" state. This asymmetry could be exploited in quantum error correction (by encoding the "no-error" syndrome of the ancilla qubits in the "bright" state), as could the likelihood values computed (which quantify confidence in the measurement outcome). We then extend the work to parallel readout of a four-ion string using a CCD camera and achieve the same 99.99% net fidelity, limited by qubit decay in the 400us exposure time. The behaviour of the camera is characterised by fitting experimental data with a model. The additional readout error due to cross-talk between ion images on the CCD is measured in an experiment designed to remove the effect of qubit decay; a spatial maximum likelihood technique is used to reduce this error to only 0.2(1)x10^{-4} per qubit, despite the presence of ~4% optical cross-talk between neighbouring qubits. Studies of the cross-talk indicate that the readout method would scale with negligible loss of fidelity to parallel readout of ~10,000 qubits with a readout time of ~3us per qubit. Monte-Carlo simulations of the readout process are presented for comparison with experimental data; these are also used to explore the parameter space associated with fluorescence detection and to optimise experimental and analysis parameters. Applications of the analysis methods to readout of other atomic and solid-state qubits are discussed.
Neutral atom quantum processors have emerged as a promising platform for scalable quantum information processing, offering high-fidelity operations and exceptional qubit scalability. A key challenge in realizing practical applications is efficiently extracting readout outcomes while maintaining high system throughput, i.e., the rate of quantum task executions. In this work, we develop a theoretical framework to quantify the trade-off between readout fidelity and atomic retention. Moreover, we introduce a metric of quantum circuit iteration rate (qCIR) and employ normalized quantum Fisher information to characterize system overall performance. Further, by carefully balancing fidelity and retention, we demonstrate a readout strategy for optimizing information acquisition efficiency. Considering the experimentally feasible parameters for 87Rb atoms, we demonstrate that qCIRs of 197.2Hz and 154.5Hz are achievable using single photon detectors and cameras, respectively. These results provide practical guidance for constructing scalable and high-throughput neutral atom quantum processors for applications in sensing, simulation, and near-term algorithm implementation.
Neutral atoms trapped in optical lattices are promising candidates for quantum information processing and quantum simulation. Over the last decades, elegant tools for the manipulation of the internal and external states of optically trapped atoms have been developed. The crucial capability of scalable internal state readout in these systems, however, still relies on destructive methods. In spite of the important role of near-resonant illumination for the manipulation and detection of atoms in the lattice, there also exists a significant lack of studies on the heating and cooling dynamics of optically trapped atoms interacting with near-resonant light. An in-depth understanding of the heating and cooling processes is essential to finding the conditions of illumination that enable the non-destructive internal state readout of multiple atoms. This work presents an experimental system to cool, trap, manipulate, and detect the internal and external states of a small ensemble of 87Rb neutral atoms trapped in a one-dimensional optical lattice. A high photon detection efficiency in our experimental system allows for fast fluorescence imaging with acquisition times of 20 ms and fast position determination of atoms in the optical lattice with an accuracy of ∼ 40 nm. Using this experimental system, we investigate the heating dynamics of a neutral atom trapped in a standing wave dipole trap illuminated by a single near-resonant laser beam. A theoretical description to describe our measurements is provided in two experimentally relevant regimes. First, we consider the case of a weak near-resonant beam and later the case of off-resonant illumination. From this analysis, we find settings for the illumination light which allows an atom to scatter many photons before it is expelled from the trap. Building on these results we demonstrate simultaneous, non-destructive determination of the internal state of spatially resolved atoms trapped in a one-dimensional optical lattice with a fidelity of 98.6 ± 0.2% and a survival probability of 99.0 ± 0.2%. During the readout process, less than 2% of the atoms change their initial ground state. In order to determine the state of atoms that are not spatially resolved, a novel image analysis technique is presented. The technique uses Bayesian methods, which include the statistics of the detected photons as well as the response from the EMCCD camera. The Bayesian method is implemented on experimental data for atoms trapped in a one-dimensional optical lattice and its accuracy is tested by numerical simulations. In addition, an extension of this algorithm for atoms trapped in two-dimensional lattices is provided. Finally, the non-destructive state detection method is utilized as a tool for the state determination following the coherent control of the internal and external states of atoms in the optical trap. Here Raman sideband cooling is implemented and utilized in an atomic compression sequence for the creation of a small and dense atomic ensemble. These techniques will play an important role in experiments studying the collective light interaction of the atomic ensemble in a recently added optical fiber cavity.
Subsystem readout during a quantum process, or mid-circuit measurement, is crucial for error correction in quantum computation, simulation, and metrology. Ideal mid-circuit measurement should be faster than the decoherence of the system, high-fidelity, and nondestructive to the unmeasured qubits. Here, we use a strongly coupled optical cavity to read out the state of a single tweezer-trapped ^{87}Rb atom within a small tweezer array. Measuring either atomic fluorescence or the transmission of light through the cavity, we detect both the presence and the state of an atom in the tweezer, within only tens of microseconds, with state preparation and measurement infidelities of roughly 0.5% and atom loss probabilities of around 1%. Using a two-tweezer system, we find measurement on one atom within the cavity causes no observable hyperfine-state decoherence on a second atom located tens of microns from the cavity volume. This high-fidelity mid-circuit readout method is a substantial step toward quantum error correction in neutral atom arrays.