Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2611.12586

Effects of pulse durations in atom interferometry with double Raman diffraction

Nadja Augst, Albert Roura

Published Nov 9, 2026• 0 citations
arXivHTMLPDF

Abstract

Double Raman diffraction is a key enabling technique for future space missions relying on atom interferometry that offers enhanced sensitivity and intrinsic suppression of systematic effects. This diffraction mechanism naturally arises when employing a retro-reflection configuration in microgravity, but then accelerations can no longer be determined through a frequency-chirp scan. As a consequence, measurements become much more sensitive to systematic effects associated with pulse timing and duration. Indeed, the finite pulse duration can introduce additional phase shifts and small modifications of the arm trajectories, which are critical sources of error in high-precision measurements. In this work, we present the first complete analytical results of these effects for double Raman diffraction, building upon previous work for single diffraction and extending the standard literature. Our analysis determines the impact of finite pulse durations on the full interferometer sequence, quantifying the shifts of the atomic wave packets' trajectories and the acquired phases. The description relies on a comprehensive framework describing matter-wave propagation in terms of central trajectories and centered wave packets, and can be easily incorporated into relativistic treatments. Furthermore, we make use of group theoretic methods that are particularly useful when accounting for residual accelerations and frequency chirps, which are also relevant for ground-based applications. Our study includes time-dependent accelerations and frequency chirps, gravity gradients, retardation effects, AC Stark shifts induced by the Raman pulses, and external forces such those due to magnetic fields or temperature gradients in the black-body radiation.

DOI
10.48550/arxiv.2611.12586

Related papers

Atomic raman diffraction: Theoretical perspectives from semi-classical to second quantized frameworks

Hartmann, Sabrina

This cumulative thesis consists of four publications [1-4], presented as three contributions (I) - (III), where the second one (II) consists of the joint publications [2,3]. All publications were written during the author's research activities at the Institute of Quantum Physics under the supervision of Prof. Dr. W. P. Schleich. All of the presented publications consider light-matter interactions and their potential application in atom interferometry, a comparatively young and rapidly evolving technique. Atom interferometers find application in high-precision measurements, the determination of physical constants, the testing of fundamental physics, and the provision of gravimeters and gyroscopes. The advancement of technology and science has led to significant improvements in performance and the development of ambitious mobile and space-based devices. The recent success of several experiments has led to the proposal of further experiments with the aim of opening up new frontiers. However, the construction of future devices necessitates a decision regarding the employed diffraction mechanism and geometry, depending on the specific technical and scientific requirements. Furthermore, it is necessary to enhance the sensitivity of future devices. The contributions in this dissertation address these issues. The first contribution (I) focuses on the diffraction of atoms by laser pulses which can be employed to generate atom-optical diffraction elements like beam splitters and mirrors. These diffraction elements can be combined to construct atom interferometers, which have been successfully employed for precision measurements regarding fundamental physics as well as practical applications. The article presents a numerical comparison of two distinct diffraction mechanisms (Bragg and Raman) and diffraction geometries (single and double diffraction) in microgravity. It discusses the fundamental differences between the mechanisms and geometries with respect to the diffraction efficiency, taking into account the width of the initial wave function and the duration of the light pulse. Additionally, it explores the transition between the two diffraction geometries when starting from an atom initially at rest and increasing its momentum. The results may serve as a reference for experimentalists in selecting the most suitable configuration, based on their aims and requirements in the realization of more advanced atom interferometers. The second contribution (II) is a follow-up to the previous one, but focuses exclusively on a single diffraction type in microgravity, namely the so-called double Raman diffraction. In contrast to the previous article, where we only discussed single two-photon processes, we consider in this article a six-photon process, also known as third-order diffraction, as well as three subsequent two-photon processes, which both lead to the same amount of transferred momentum and can both be used to realize large-momentum transfer (LMT). We demonstrate that third-order double Raman diffraction is a viable and advantageous method for the diffraction of small momentum distributions like Bose-Einstein condensates (BECs) compared to a sequence of three two-photon processes. Furthermore, we show that third-order Raman pulses can be successfully applied to create higher-order Raman atom interferometers. Third-order diffraction can be perfectly combined with other LMT techniques and, moreover, allows for a reduction in the overall duration of the diffraction process and the complexity of the experimental set-up, as only two distinct laser frequencies are required. Moreover, we present a third-order Mach-Zehnder interferometer with spurious paths being disregarded. As demonstrated later on in [3], this interferometer generates optimal contrast and a substantial amplitude. The third contribution (III) extends the semi-classical λ-scheme of single Raman diffraction, as discussed in detail in contribution (I), into a fully quantized multi-atom multi-λ configuration with center-of-mass motion inside a cavity. Therefore, the incorporation of an internal structure allows for a more realistic modeling of the atoms, which is relevant for multi-photon interaction or cooling processes. We use for our analysis the framework of second quantization, i.e., we take into account the field-theoretical nature of the multi-particle atomic field as well as of the diffracting light field. We reduce this model with a Hamiltonian averaging theory applied to the atomic field operators and obtain an effective Hamiltonian, which determines the time evolution of the system. We demonstrate the efficiency of our model by the application of a typical initial state. Moreover, for a specific input state, we obtain the Hong-Ou-Mandel effect simultaneously in the atomic and the optical system. Our many-body formalism is perfectly suited to theoretically describe contemporary high-precision atom interferometric experiments based on entanglement between the atoms, that aim to surpass the shot-noise limit.

•Jan 1, 2025•0 citations

Analytical framework for dynamic light pulse atom interferometry at short interrogation times

Richard E. Stoner, David L. Butts, Joseph M. Kinast +1 more

High-precision inertial sensing demonstrations with light pulse atom interferometry have typically used Raman pulses having durations orders of magnitude shorter than the dwell time between interferometer pulses. Environmentally robust sensors operating at high-bandwidth will be required to operate at short (millisecond scale) dwell times between Raman pulses. In such an operational mode, the Raman pulse duration becomes an appreciable fraction of the dwell time between pulses. In addition, high-precision inertial sensing applications have typically been demonstrated in mildly dynamic or nondynamic environments having low rate of change of inertial input, ensuring that applied Raman pulses satisfy the Raman resonance condition. Application of nonresonant pulses will be inevitable in sensors registering time-varying inertial input. We present a diagrammatic technique for calculation of atomic output state populations for multipulse atom optics manipulations that explicitly account for the effects of finite pulse duration and finite Raman detuning effects on the laser-induced atomic phase. We analyze several atom interferometer sequences. We report accelerometer and gyroscope phase evolution for fixed Raman laser frequency difference incorporating corrections in powers of the ratio of pulse duration to time interval between interferometer pulses. Our accelerometer result agrees with other published results.

Journal of the Optical Society of America B•Sep 13, 2011•29 citations

Raman-pulse-duration effect in gravity gradiometers composed of two atom interferometers

Cheng-Gang Shao, Dekai Mao, Min-Kang Zhou +4 more

We investigated the Raman-pulse-duration effect in a gravity gradiometer with two atom interferometers. Since the two atom clouds in the gradiometer experience different gravitational fields, it is hard to compensate for the Doppler shifts of the two clouds simultaneously by chirping the frequency of a common Raman laser. This leads to an appreciable phase shift. The magnitude of the phase shift relative to the differential phase shift of the two interferometers is in an order of $\ensuremath{\tau}/T$, and cannot be neglected in the precision measurements such as measuring the gravity gradient and the Newtonian gravitational constant.

arXiv:1503.01199•Physical Review A•Nov 16, 2015•7 citations

Evaluation of a frequency-dependent phase shift in chirped Raman lasers for atom gravimeters

Yaoyao Xu, Qingsong Wang, Jiafeng Cui +6 more

Light-pulse atom gravimetry has emerged as a powerful technique for precisely measuring absolute gravitational acceleration. Raman lasers are commonly used in this technique to coherently manipulate the atomic wave packet, of which the effective frequency is chirped continuously to compensate for the Doppler shift. In this study we investigate an additional phase shift in the Raman lasers that arises due to the frequency chirp. We directly measure this phase shift by recording the beat signal of the Raman lasers with a high-speed oscilloscope, providing an independent evaluation of the resultant error in atom gravimeters caused by this phase shift. Concurrently, we detect the influence of the additional phase shift on gravity measurements using our atom gravimeter, and the results are in good agreement with the independent evaluation. Notably, there may still be a residual error at the microgal level when performing differential measurements by reversing the direction of the effective wave vector of the Raman lasers. We propose that this residual error can in principle be eliminated by selecting the same chirp frequency range for both directions in the differential measurement.

Physical Review A•Dec 19, 2024•2 citations

Finite-Speed-of-Light Effects in Atom Interferometry: Diffraction Mechanisms and Resonance Conditions

Christian Niehof, Daniel Derr, Enno Giese

Light-pulse atom interferometers serve as tools for high-precision metrology and are targeting measurements of relativistic effects. This development is facilitated by extended interrogation times and large-momentum-transfer techniques generating quantum superpositions of both interferometer arms on large distances. Due to the finite speed of light, diffracting light pulses cannot interact simultaneously with both arms, inducing phase perturbations that compromise the accuracy of the sensor -- an effect that becomes progressively important as spatial separations increase. For a consistent framework, we develop a theory for finite-speed-of-light effects in atom interferometers alongside with other relativistic effects such as the mass defect. Our analysis shows that their magnitude depends crucially on the diffraction mechanism and the specific interferometer geometry. We demonstrate that the velocity of the atomic cloud at the mirror pulse of a Mach-Zehnder interferometer is less critical than the precise tuning of the lasers for resonant diffraction. Finally, we propose an experiment to test our predictions based on recoilless transitions and discuss mitigation strategies to reduce the bias in gravimetric applications.

arXiv:2505.02728•May 5, 2025•2 citations

Double Bragg diffraction: A tool for atom optics

Enno Giese, Albert Roura, Gunnar Tackmann +2 more

The use of retroreflection in light-pulse atom interferometry under microgravity conditions naturally leads to a double-diffraction scheme. The two pairs of counterpropagating beams induce simultaneously transitions with opposite momentum transfer that, when acting on atoms initially at rest, give rise to symmetric interferometer configurations where the total momentum transfer is automatically doubled and where a number of noise sources and systematic effects cancel out. Here we extend earlier implementations for Raman transitions to the case of Bragg diffraction. In contrast with the single-diffraction case, the existence of additional off-resonant transitions between resonantly connected states precludes the use of the adiabatic elimination technique. Nevertheless, we have been able to obtain analytic results even beyond the deep Bragg regime by employing the so-called ``method of averaging,'' which can be applied to more general situations of this kind. Our results have been validated by comparison to numerical solutions of the basic equations describing the double-diffraction process.

arXiv:1308.5205•Physical Review A•Nov 8, 2013•96 citations
Double Raman diffraction is a key enabling technique for future space missions relying on atom interferometry that offers enhanced sensitivity and intrinsic suppression of systematic effects. This diffraction mechanism naturally arises when employing a retro-reflection configuration in microgravity, but then accelerations can no longer be determined through a frequency-chirp scan. As a consequence, measurements become much more sensitive to systematic effects associated with pulse timing and duration. Indeed, the finite pulse duration can introduce additional phase shifts and small modifications of the arm trajectories, which are critical sources of error in high-precision measurements. In this work, we present the first complete analytical results of these effects for double Raman diffraction, building upon previous work for single diffraction and extending the standard literature. Our analysis determines the impact of finite pulse durations on the full interferometer sequence, quantifying the shifts of the atomic wave packets' trajectories and the acquired phases. The description relies on a comprehensive framework describing matter-wave propagation in terms of central trajectories and centered wave packets, and can be easily incorporated into relativistic treatments. Furthermore, we make use of group theoretic methods that are particularly useful when accounting for residual accelerations and frequency chirps, which are also relevant for ground-based applications. Our study includes time-dependent accelerations and frequency chirps, gravity gradients, retardation effects, AC Stark shifts induced by the Raman pulses, and external forces such those due to magnetic fields or temperature gradients in the black-body radiation.
This cumulative thesis consists of four publications [1-4], presented as three contributions (I) - (III), where the second one (II) consists of the joint publications [2,3]. All publications were written during the author's research activities at the Institute of Quantum Physics under the supervision of Prof. Dr. W. P. Schleich. All of the presented publications consider light-matter interactions and their potential application in atom interferometry, a comparatively young and rapidly evolving technique. Atom interferometers find application in high-precision measurements, the determination of physical constants, the testing of fundamental physics, and the provision of gravimeters and gyroscopes. The advancement of technology and science has led to significant improvements in performance and the development of ambitious mobile and space-based devices. The recent success of several experiments has led to the proposal of further experiments with the aim of opening up new frontiers. However, the construction of future devices necessitates a decision regarding the employed diffraction mechanism and geometry, depending on the specific technical and scientific requirements. Furthermore, it is necessary to enhance the sensitivity of future devices. The contributions in this dissertation address these issues. The first contribution (I) focuses on the diffraction of atoms by laser pulses which can be employed to generate atom-optical diffraction elements like beam splitters and mirrors. These diffraction elements can be combined to construct atom interferometers, which have been successfully employed for precision measurements regarding fundamental physics as well as practical applications. The article presents a numerical comparison of two distinct diffraction mechanisms (Bragg and Raman) and diffraction geometries (single and double diffraction) in microgravity. It discusses the fundamental differences between the mechanisms and geometries with respect to the diffraction efficiency, taking into account the width of the initial wave function and the duration of the light pulse. Additionally, it explores the transition between the two diffraction geometries when starting from an atom initially at rest and increasing its momentum. The results may serve as a reference for experimentalists in selecting the most suitable configuration, based on their aims and requirements in the realization of more advanced atom interferometers. The second contribution (II) is a follow-up to the previous one, but focuses exclusively on a single diffraction type in microgravity, namely the so-called double Raman diffraction. In contrast to the previous article, where we only discussed single two-photon processes, we consider in this article a six-photon process, also known as third-order diffraction, as well as three subsequent two-photon processes, which both lead to the same amount of transferred momentum and can both be used to realize large-momentum transfer (LMT). We demonstrate that third-order double Raman diffraction is a viable and advantageous method for the diffraction of small momentum distributions like Bose-Einstein condensates (BECs) compared to a sequence of three two-photon processes. Furthermore, we show that third-order Raman pulses can be successfully applied to create higher-order Raman atom interferometers. Third-order diffraction can be perfectly combined with other LMT techniques and, moreover, allows for a reduction in the overall duration of the diffraction process and the complexity of the experimental set-up, as only two distinct laser frequencies are required. Moreover, we present a third-order Mach-Zehnder interferometer with spurious paths being disregarded. As demonstrated later on in [3], this interferometer generates optimal contrast and a substantial amplitude. The third contribution (III) extends the semi-classical λ-scheme of single Raman diffraction, as discussed in detail in contribution (I), into a fully quantized multi-atom multi-λ configuration with center-of-mass motion inside a cavity. Therefore, the incorporation of an internal structure allows for a more realistic modeling of the atoms, which is relevant for multi-photon interaction or cooling processes. We use for our analysis the framework of second quantization, i.e., we take into account the field-theoretical nature of the multi-particle atomic field as well as of the diffracting light field. We reduce this model with a Hamiltonian averaging theory applied to the atomic field operators and obtain an effective Hamiltonian, which determines the time evolution of the system. We demonstrate the efficiency of our model by the application of a typical initial state. Moreover, for a specific input state, we obtain the Hong-Ou-Mandel effect simultaneously in the atomic and the optical system. Our many-body formalism is perfectly suited to theoretically describe contemporary high-precision atom interferometric experiments based on entanglement between the atoms, that aim to surpass the shot-noise limit.
High-precision inertial sensing demonstrations with light pulse atom interferometry have typically used Raman pulses having durations orders of magnitude shorter than the dwell time between interferometer pulses. Environmentally robust sensors operating at high-bandwidth will be required to operate at short (millisecond scale) dwell times between Raman pulses. In such an operational mode, the Raman pulse duration becomes an appreciable fraction of the dwell time between pulses. In addition, high-precision inertial sensing applications have typically been demonstrated in mildly dynamic or nondynamic environments having low rate of change of inertial input, ensuring that applied Raman pulses satisfy the Raman resonance condition. Application of nonresonant pulses will be inevitable in sensors registering time-varying inertial input. We present a diagrammatic technique for calculation of atomic output state populations for multipulse atom optics manipulations that explicitly account for the effects of finite pulse duration and finite Raman detuning effects on the laser-induced atomic phase. We analyze several atom interferometer sequences. We report accelerometer and gyroscope phase evolution for fixed Raman laser frequency difference incorporating corrections in powers of the ratio of pulse duration to time interval between interferometer pulses. Our accelerometer result agrees with other published results.
We investigated the Raman-pulse-duration effect in a gravity gradiometer with two atom interferometers. Since the two atom clouds in the gradiometer experience different gravitational fields, it is hard to compensate for the Doppler shifts of the two clouds simultaneously by chirping the frequency of a common Raman laser. This leads to an appreciable phase shift. The magnitude of the phase shift relative to the differential phase shift of the two interferometers is in an order of $\ensuremath{\tau}/T$, and cannot be neglected in the precision measurements such as measuring the gravity gradient and the Newtonian gravitational constant.
Light-pulse atom gravimetry has emerged as a powerful technique for precisely measuring absolute gravitational acceleration. Raman lasers are commonly used in this technique to coherently manipulate the atomic wave packet, of which the effective frequency is chirped continuously to compensate for the Doppler shift. In this study we investigate an additional phase shift in the Raman lasers that arises due to the frequency chirp. We directly measure this phase shift by recording the beat signal of the Raman lasers with a high-speed oscilloscope, providing an independent evaluation of the resultant error in atom gravimeters caused by this phase shift. Concurrently, we detect the influence of the additional phase shift on gravity measurements using our atom gravimeter, and the results are in good agreement with the independent evaluation. Notably, there may still be a residual error at the microgal level when performing differential measurements by reversing the direction of the effective wave vector of the Raman lasers. We propose that this residual error can in principle be eliminated by selecting the same chirp frequency range for both directions in the differential measurement.
Light-pulse atom interferometers serve as tools for high-precision metrology and are targeting measurements of relativistic effects. This development is facilitated by extended interrogation times and large-momentum-transfer techniques generating quantum superpositions of both interferometer arms on large distances. Due to the finite speed of light, diffracting light pulses cannot interact simultaneously with both arms, inducing phase perturbations that compromise the accuracy of the sensor -- an effect that becomes progressively important as spatial separations increase. For a consistent framework, we develop a theory for finite-speed-of-light effects in atom interferometers alongside with other relativistic effects such as the mass defect. Our analysis shows that their magnitude depends crucially on the diffraction mechanism and the specific interferometer geometry. We demonstrate that the velocity of the atomic cloud at the mirror pulse of a Mach-Zehnder interferometer is less critical than the precise tuning of the lasers for resonant diffraction. Finally, we propose an experiment to test our predictions based on recoilless transitions and discuss mitigation strategies to reduce the bias in gravimetric applications.
The use of retroreflection in light-pulse atom interferometry under microgravity conditions naturally leads to a double-diffraction scheme. The two pairs of counterpropagating beams induce simultaneously transitions with opposite momentum transfer that, when acting on atoms initially at rest, give rise to symmetric interferometer configurations where the total momentum transfer is automatically doubled and where a number of noise sources and systematic effects cancel out. Here we extend earlier implementations for Raman transitions to the case of Bragg diffraction. In contrast with the single-diffraction case, the existence of additional off-resonant transitions between resonantly connected states precludes the use of the adiabatic elimination technique. Nevertheless, we have been able to obtain analytic results even beyond the deep Bragg regime by employing the so-called ``method of averaging,'' which can be applied to more general situations of this kind. Our results have been validated by comparison to numerical solutions of the basic equations describing the double-diffraction process.