arXiv:2611.03984
The Impact of Internal Electric Fields on Accurate Diamond Magnetometry
Jack Faller, Daphne Freda Gavras, Andrew Lowther, Romain Ruhlmann, Lilian Childress
Abstract
Nitrogen-vacancy (NV) center spin ensembles are a promising platform for accurate vector magnetometry, as they offer measurements referenced to a spin Hamiltonian in an anisotropic crystal with native vector sensing capabilities. However, charged dopants within the diamond produce random internal electric fields (RIEFs) that shift NV spin-transition frequencies, and their impact on the accuracy of NV magnetometry has not been investigated. Here, we characterize RIEFs' effect on NV spin-transition spectra and propose an analytical fitting function to improve accuracy in their presence. We build a Monte Carlo RIEF model that reproduces the asymmetric lineshapes observed in experimental optically detected magnetic resonance (ODMR) spectra, and use it as a testbed to quantify RIEF-induced errors by simulating ODMR spectra including RIEFs and comparing reconstructed magnetic fields to the known model input. With standard analysis approaches, we observe systematic errors exceeding the g-factor uncertainty in fields below $\sim$ 5 mT, while the proposed fitting function reduces the error by nearly an order of magnitude. Our results demonstrate that RIEFs can play a significant role in the systematic error budget for NV magnetometry, and offer a path towards improved accuracy in NV quantum sensing.
AI Summary
This paper asks how random internal electric fields (RIEFs) from charged dopants bias absolute magnetic-field estimates in NV-ensemble magnetometry, beyond their established effect on zero-field sensitivity. A Monte Carlo model assigns electrons to randomly placed NV centers from nearby nitrogen donors, computes local electric fields, and generates spin-transition spectra with magnetic and microwave broadening. It reproduces asymmetric features in experimental finite-bias ODMR spectra that symmetric Voigt profiles do not capture. Systematic errors are quantified by reconstructing known input fields from simulated spectra. For representative concentrations $[\mathrm{NV}^-]=2.7$ ppm and $[\mathrm{N}]=8.5$ ppm, with $T_2^*=1.24\,\mu\mathrm{s}$, conventional peak or Voigt-based estimates show errors exceeding $1\,\mu\mathrm{T}$ at few-mT axial fields. The errors decrease approximately as $B_z^{-1/2}$ over the simulated range, rather than the naively expected $B_z^{-1}$. An analytical asymmetric fitting function, derived using approximately Cauchy-distributed electric-field components, reduces axial-field errors by roughly an order of magnitude. Four-orientation vector reconstruction shows errors up to approximately $5\,\mu\mathrm{T}$ near a 1 mT bias; the fitting advantage diminishes at larger fields. Microwave broadening also shifts inferred fields. The accuracy improvements are simulation-based, not demonstrated against an experimental reference field. The charge model assumes homogeneous dopant distributions and dielectric screening and neglects optical charge dynamics. Most calculations omit nonsecular hyperfine interactions, and the analytical fit assumes an axial field and approximate field distributions. Strain, mosaicity, and other solid-state effects remain outside the modeled accuracy budget.
An illustration of the Monte Carlo NV$^-$-N$^+$ pair model (generated with code from Claude Sonnet 4.6).
Error found: The abstract leaves the nearly order-of-magnitude fitting improvement unqualified, whereas the body establishes that magnitude for aligned single-axis simulations and reports a field-dependent advantage for vector reconstruction that disappears around 8 mT.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 14 pages, 8 figures