Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.01227

Terrestrial Gravitational Wave Detection with Atom Interferometers

Michael Werner, Ashkan Alibabaei, Naceur Gaaloul

quant-phSubmitted Aug 31, 2026• Announced Sep 1, 2026
arXivHTMLPDF

Abstract

Atom interferometers (AIFs) are highly precise inertial sensors and are considered promising instruments for the detection of gravitational waves (GWs) and certain dark matter (DM) candidates in the mid-frequency band. While GW detection with AIFs was initially proposed for space-based experiments with baselines spanning thousands of kilometers, recent developments suggest that terrestrial setups with baselines of at least 100 meters may also be capable of detecting GWs. In this work, we analytically derive the GW phase response formula of a ground detector, find an additional term compared to the existing literature and check it our findings numerically. Based on this treatment, we analyze the optimal geometric parameters for earth-bound AIF experiments. Subsequently, we numerically simulate GW detection schemes for these optimized interferometers using an open-source Python algorithm. Numerical simulations of these schemes have are not available to the community, yet crucial for the accurate modeling of noise and non-trivial gravitational backgrounds.

Comments
14 pages, 7 figures

Related papers

Atom interferometry and the Earth sciences

Jeremiah Mitchell

Atom interferometry is a quantum sensor technology that uses ultra-cold atoms placed in entangled quantum states to detect minute changes in local fields arising from gravitational waves and ultra-light dark matter. Their extreme sensitivity to accelerations has been demonstrated for measurements of Newton’s gravitation constant, tests of the Equivalence Principle, and measurement of local gravity gradients. The search for ultra-light dark matter and measurements of gravitational waves requires interferometer baselines greater than approximately 100 m. In understanding the fundamental systematics and backgrounds of these detectors, we have discovered that atmospheric and seismic effects, even though physically decoupled from the atoms which are in vacuum and free-fall, are still detectable by the quantum phase of the atoms. From a different perspective these “noise” sources are also interesting signals that we may be able to understand better with these sensor platforms leading to cross-disciplinary studies in Earth sciences.

Optical and Quantum Sensing and Precision Metrology II•Mar 13, 2024•0 citations

A prototype differential atom interferometer for fundamental physics.

C. Baynham, Richard Hobson, O. L. Buchmueller +90 more

Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for very-long-baseline atom interferometerssuch as AION1, MAGIS2, AICE3 and AEDGE4 that aim to detect at frequencies at which ground-based5 and space-borne6 laser interferometers lose sensitivity. Very-long-baseline atom interferometers look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. The experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87Sr. Thus, we obtain a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the standard quantum limit7 with no excess noise beyond atom shot noise. The differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, which emulates the conditions expected in a very-long-baseline atom interferometer. We also demonstrate the recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomized conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying very-long-baseline atom interferometers and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter8,9.

•Apr 10, 2025•0 citations

A prototype differential atom interferometer for fundamental physics

Charles F. A. Baynham, Richard Hobson, O. L. Buchmueller +97 more

Abstract Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for very-long-baseline atom interferometerssuch as AION 1 , MAGIS 2 , AICE 3 and AEDGE 4 that aim to detect at frequencies at which ground-based 5 and space-borne 6 laser interferometers lose sensitivity. Very-long-baseline atom interferometers look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. The experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87 Sr. Thus, we obtain a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the standard quantum limit 7 with no excess noise beyond atom shot noise. The differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, which emulates the conditions expected in a very-long-baseline atom interferometer. We also demonstrate the recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomized conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying very-long-baseline atom interferometers and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter 8,9 .

arXiv:2504.09158•Nature•Jun 17, 2026•3 citations

Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100)

Mahiro Abe, P. Adamson, Marcel Borcean +45 more

Abstract MAGIS-100 is a next-generation quantum sensor under construction at Fermilab that aims to explore fundamental physics with atom interferometry over a 100 m baseline. This novel detector will search for ultralight dark matter, test quantum mechanics in new regimes, and serve as a technology pathfinder for future gravitational wave detectors in a previously unexplored frequency band. It combines techniques demonstrated in state-of-the-art 10-meter-scale atom interferometers with the latest technological advances of the world’s best atomic clocks. MAGIS-100 will provide a development platform for a future kilometer-scale detector that would be sufficiently sensitive to detect gravitational waves from known sources. Here we present the science case for the MAGIS concept, review the operating principles of the detector, describe the instrument design, and study the detector systematics.

arXiv:2104.02835•Quantum Science and Technology•Apr 12, 2021•233 citations

Atom Interferometry for Detection of Gravitational Waves

Babak N. Saif, Jason M. Hogan, Mark A. Kasevich

This report presents the results of the 2012-2013 NASA Institute for Advanced Concepts (NIAC) Phase 1 Atom Interferometry for Detection of Gravitational Waves project. The origin of this GW (Gravitational Wave) detection concept using atoms can be traced to theoretical work that first appeared in 2008 and also to a satellite mission-focused followup study that was done in 2011. The goal of the current project was to explore both theoretical and technical issues surrounding the implementation of this idea, as well as to begin performing proof-of-concept experiments to validate critical aspects of the proposal.The top level trade space for the detector design is driven by the strategy employed to mitigate laser frequency noise, which, if uncontrolled, can mask GW signatures. One of the advantages of the atom interferometric approach is the possibility of single baseline detection (Fig. 1.1), even in the presence of laser noise. This is enabled by the differential measurement between the two ensembles of atoms, which can result in substantial laser noise suppression. The details of this suppression depend on the atomic physics techniques used to implement the atom interferometry. Specifically, we considered the effect on noise suppression that results from using traditional two-photon Raman transitions (with alkali atoms) and also single-photon transitions (with alkaline earth-like atoms).The interferometers shown in Fig 1.1(b) take advantage of single-photon transitions (as opposed to traditional Raman transitions) because using light pulses from one direction at a time allows for near perfect common-mode cancellation of laser phase noise, even for long baselines. This calls for the use of atomic transitions with an (ideally large) optical energy level difference with a long (greater than 1 second) lifetime, such as high-transitions routinely used for optical atomic clocks in species like Sr, Ca and Yb. Notably, large momentum transfer (LMT) atom optics - and the sensitivity enhancement they confer – can still be realized by simply adding additional pairs of alternating pulses to each beam splitter process. Section 3 reports on the theoretical work we performed to justify this GW detection protocol using single-photon transitions. This approach represents a new method for GW detection using atoms that is distinct from the original proposal from 2008. At the system level, we evaluated three architectures, each of which implements a different solution to the laser frequency noise issue. The first two designs are based on two-photon Raman transitions with Rb atoms. One of these is a three-satellite, multiple baseline design while the other is a two-satellite, single baseline design. The third proposal is a two-satellite, single baseline design that uses single-photon transitions with Sr atoms. These three architectures are described in more detail in Section 2. There are a number of known technical issues that we have started to address using ground-based experiments. These issues include atom technology development needs such as, for example, lower ensemble temperature requirements and large momentum transfer (LMT) atom optics. To this end, we have built a 10-meter scale atom drop tower, where we can perform proof-of-principle demonstrations of the proposed AGIS detector in an environment that permits more than 2.5 seconds of free-fall time. This facility allows for demonstration of atom interferometry with long interrogation time (seconds) and large atom wavepacket

•Jul 9, 2013•0 citations

Spatial and pulse efficiency constraints in atom interferometric gravitational wave detectors

Patrik Schach, Enno Giese

Abstract Currently planned and constructed terrestrial detectors for gravitational waves and dark matter based on differential light-pulse atom interferometry are designed around three primary strategies to enhance their sensitivity: (i) Resonant-mode enhancement using multiple diamonds, (ii) large-momentum-transfer (LMT) techniques to increase arm separation within the interferometer, and (iii) very-long baseline schemes that increase the distance between the two interferometers. Both resonant-mode enhancement and LMT techniques result in a greater number of light pulses, making high pulse fidelity during atom-light interactions imperative. At the same time, increasing the number of diamonds in vertical configurations leads to taller atomic fountains, which consequently reduces the available distance between interferometers. As a result, the number of diamonds, LMT pulses, and the fountain height are interdependent parameters that must be carefully balanced. In this work, we present optimal configurations for multi-diamond geometries in resonant mode, explicitly accounting for the spatial extent of a single interferometer, considering constraints imposed by the baseline dimensions and atomic losses due to imperfect pulses. For this optimization, we numerically scan the relevant parameters such as initial position and momentum of the atomic cloud, transferred momenta, and number of loops. For each parameter set, we verify whether the imposed conditions are met and evaluate the resulting sensitivities to identify optimal configurations. We provide practical analytical relations to estimate the optimal number of pulses that should be applied. Many proposals beyond demonstrator experiments require pulse numbers that demand efficiencies not yet demonstrated with state-of-the-art momentum transfer techniques. As a result, the observed sensitivity falls short of expectations—an effect caused by both arm separation and atom loss per pulse—highlighting the urgent need for research aimed at improving pulse fidelities.

arXiv:2506.09511•Quantum Science and Technology•Aug 27, 2025•3 citations
Atom interferometers (AIFs) are highly precise inertial sensors and are considered promising instruments for the detection of gravitational waves (GWs) and certain dark matter (DM) candidates in the mid-frequency band. While GW detection with AIFs was initially proposed for space-based experiments with baselines spanning thousands of kilometers, recent developments suggest that terrestrial setups with baselines of at least 100 meters may also be capable of detecting GWs. In this work, we analytically derive the GW phase response formula of a ground detector, find an additional term compared to the existing literature and check it our findings numerically. Based on this treatment, we analyze the optimal geometric parameters for earth-bound AIF experiments. Subsequently, we numerically simulate GW detection schemes for these optimized interferometers using an open-source Python algorithm. Numerical simulations of these schemes have are not available to the community, yet crucial for the accurate modeling of noise and non-trivial gravitational backgrounds.
Atom interferometry is a quantum sensor technology that uses ultra-cold atoms placed in entangled quantum states to detect minute changes in local fields arising from gravitational waves and ultra-light dark matter. Their extreme sensitivity to accelerations has been demonstrated for measurements of Newton’s gravitation constant, tests of the Equivalence Principle, and measurement of local gravity gradients. The search for ultra-light dark matter and measurements of gravitational waves requires interferometer baselines greater than approximately 100 m. In understanding the fundamental systematics and backgrounds of these detectors, we have discovered that atmospheric and seismic effects, even though physically decoupled from the atoms which are in vacuum and free-fall, are still detectable by the quantum phase of the atoms. From a different perspective these “noise” sources are also interesting signals that we may be able to understand better with these sensor platforms leading to cross-disciplinary studies in Earth sciences.
Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for very-long-baseline atom interferometerssuch as AION1, MAGIS2, AICE3 and AEDGE4 that aim to detect at frequencies at which ground-based5 and space-borne6 laser interferometers lose sensitivity. Very-long-baseline atom interferometers look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. The experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87Sr. Thus, we obtain a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the standard quantum limit7 with no excess noise beyond atom shot noise. The differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, which emulates the conditions expected in a very-long-baseline atom interferometer. We also demonstrate the recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomized conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying very-long-baseline atom interferometers and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter8,9.
Abstract Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for very-long-baseline atom interferometerssuch as AION 1 , MAGIS 2 , AICE 3 and AEDGE 4 that aim to detect at frequencies at which ground-based 5 and space-borne 6 laser interferometers lose sensitivity. Very-long-baseline atom interferometers look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. The experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87 Sr. Thus, we obtain a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the standard quantum limit 7 with no excess noise beyond atom shot noise. The differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, which emulates the conditions expected in a very-long-baseline atom interferometer. We also demonstrate the recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomized conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying very-long-baseline atom interferometers and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter 8,9 .
Abstract MAGIS-100 is a next-generation quantum sensor under construction at Fermilab that aims to explore fundamental physics with atom interferometry over a 100 m baseline. This novel detector will search for ultralight dark matter, test quantum mechanics in new regimes, and serve as a technology pathfinder for future gravitational wave detectors in a previously unexplored frequency band. It combines techniques demonstrated in state-of-the-art 10-meter-scale atom interferometers with the latest technological advances of the world’s best atomic clocks. MAGIS-100 will provide a development platform for a future kilometer-scale detector that would be sufficiently sensitive to detect gravitational waves from known sources. Here we present the science case for the MAGIS concept, review the operating principles of the detector, describe the instrument design, and study the detector systematics.
This report presents the results of the 2012-2013 NASA Institute for Advanced Concepts (NIAC) Phase 1 Atom Interferometry for Detection of Gravitational Waves project. The origin of this GW (Gravitational Wave) detection concept using atoms can be traced to theoretical work that first appeared in 2008 and also to a satellite mission-focused followup study that was done in 2011. The goal of the current project was to explore both theoretical and technical issues surrounding the implementation of this idea, as well as to begin performing proof-of-concept experiments to validate critical aspects of the proposal.The top level trade space for the detector design is driven by the strategy employed to mitigate laser frequency noise, which, if uncontrolled, can mask GW signatures. One of the advantages of the atom interferometric approach is the possibility of single baseline detection (Fig. 1.1), even in the presence of laser noise. This is enabled by the differential measurement between the two ensembles of atoms, which can result in substantial laser noise suppression. The details of this suppression depend on the atomic physics techniques used to implement the atom interferometry. Specifically, we considered the effect on noise suppression that results from using traditional two-photon Raman transitions (with alkali atoms) and also single-photon transitions (with alkaline earth-like atoms).The interferometers shown in Fig 1.1(b) take advantage of single-photon transitions (as opposed to traditional Raman transitions) because using light pulses from one direction at a time allows for near perfect common-mode cancellation of laser phase noise, even for long baselines. This calls for the use of atomic transitions with an (ideally large) optical energy level difference with a long (greater than 1 second) lifetime, such as high-transitions routinely used for optical atomic clocks in species like Sr, Ca and Yb. Notably, large momentum transfer (LMT) atom optics - and the sensitivity enhancement they confer – can still be realized by simply adding additional pairs of alternating pulses to each beam splitter process. Section 3 reports on the theoretical work we performed to justify this GW detection protocol using single-photon transitions. This approach represents a new method for GW detection using atoms that is distinct from the original proposal from 2008. At the system level, we evaluated three architectures, each of which implements a different solution to the laser frequency noise issue. The first two designs are based on two-photon Raman transitions with Rb atoms. One of these is a three-satellite, multiple baseline design while the other is a two-satellite, single baseline design. The third proposal is a two-satellite, single baseline design that uses single-photon transitions with Sr atoms. These three architectures are described in more detail in Section 2. There are a number of known technical issues that we have started to address using ground-based experiments. These issues include atom technology development needs such as, for example, lower ensemble temperature requirements and large momentum transfer (LMT) atom optics. To this end, we have built a 10-meter scale atom drop tower, where we can perform proof-of-principle demonstrations of the proposed AGIS detector in an environment that permits more than 2.5 seconds of free-fall time. This facility allows for demonstration of atom interferometry with long interrogation time (seconds) and large atom wavepacket
Abstract Currently planned and constructed terrestrial detectors for gravitational waves and dark matter based on differential light-pulse atom interferometry are designed around three primary strategies to enhance their sensitivity: (i) Resonant-mode enhancement using multiple diamonds, (ii) large-momentum-transfer (LMT) techniques to increase arm separation within the interferometer, and (iii) very-long baseline schemes that increase the distance between the two interferometers. Both resonant-mode enhancement and LMT techniques result in a greater number of light pulses, making high pulse fidelity during atom-light interactions imperative. At the same time, increasing the number of diamonds in vertical configurations leads to taller atomic fountains, which consequently reduces the available distance between interferometers. As a result, the number of diamonds, LMT pulses, and the fountain height are interdependent parameters that must be carefully balanced. In this work, we present optimal configurations for multi-diamond geometries in resonant mode, explicitly accounting for the spatial extent of a single interferometer, considering constraints imposed by the baseline dimensions and atomic losses due to imperfect pulses. For this optimization, we numerically scan the relevant parameters such as initial position and momentum of the atomic cloud, transferred momenta, and number of loops. For each parameter set, we verify whether the imposed conditions are met and evaluate the resulting sensitivities to identify optimal configurations. We provide practical analytical relations to estimate the optimal number of pulses that should be applied. Many proposals beyond demonstrator experiments require pulse numbers that demand efficiencies not yet demonstrated with state-of-the-art momentum transfer techniques. As a result, the observed sensitivity falls short of expectations—an effect caused by both arm separation and atom loss per pulse—highlighting the urgent need for research aimed at improving pulse fidelities.