Anderson Orthogonality as Measurement Backaction in Coupled Quantum Dots
Will Grant, Sarath Sankar, Elena Cornick, Vahid Movahed, Johann Drayne, Silvia Lüscher, Saeed Fallahi, Geoffrey C. Gardner, Michael J. Manfra, Eran Sela, Yigal Meir, Joshua Folk
Measurement perturbs a quantum system by coupling it to external degrees of freedom, but detector backaction depends on the physical mechanism of measurement itself. In solid-state devices, detectors driven far from equilibrium to enable faster measurements produce backaction that can often be understood as classical noise. However, a strong measurement can also induce backaction from quantum many-body correlations in the detector that are intrinsic to the measurement, even without shot noise. Here, we probe this near-equilibrium backaction through the effect of a quantum-dot charge sensor on tunnelling between a second quantum dot and its reservoirs. The measurement realizes the Anderson Orthogonality Catastrophe (AOC): electrons in the detector leads reorganize in response to an abrupt change in local scattering potential, suppressing resonant tunnelling while enabling inelastic processes that exchange energy with the detector. Changing the detector energy level tunes the AOC backaction from negligible to dominant in the tunnelling dynamics. More broadly, these results establish detector-induced many-body correlations as a controllable influence on quantum dynamics.
Measurement perturbs a quantum system by coupling it to external degrees of freedom, but detector backaction depends on the physical mechanism of measurement itself. In solid-state devices, detectors driven far from equilibrium to enable faster measurements produce backaction that can often be understood as classical noise. However, a strong measurement can also induce backaction from quantum many-body correlations in the detector that are intrinsic to the measurement, even without shot noise. Here, we probe this near-equilibrium backaction through the effect of a quantum-dot charge sensor on tunnelling between a second quantum dot and its reservoirs. The measurement realizes the Anderson Orthogonality Catastrophe (AOC): electrons in the detector leads reorganize in response to an abrupt change in local scattering potential, suppressing resonant tunnelling while enabling inelastic processes that exchange energy with the detector. Changing the detector energy level tunes the AOC backaction from negligible to dominant in the tunnelling dynamics. More broadly, these results establish detector-induced many-body correlations as a controllable influence on quantum dynamics.
We derive an analytical expression for the backaction dephasing rate, which characterizes the disturbance induced by coupling with an environment containing a quantum dot detector (QDD). In this paper, we show in an explicit form that the charge noise induces backaction dephasing. In equilibrium, this backaction dephasing induced by the charge noise can be explained as a relaxation by an inelastic electron-electron scattering in Fermi-liquid theory. Unlike the quantum point contact, the backaction dephasing rate increases or decreases with the bias at low bias and finite-temperature condition. This behavior depends on the QDD energy level with respect to the Fermi energy and the asymmetry of the QDD coupling to the reservoirs. In the high bias voltage regime, the dephasing rate becomes insensitive to the bias because of the saturation of the charge noise.
Quantum information processing is a key technology in the ongoing second quantum revolution, with a wide variety of hardware platforms competing toward its realization. An indispensable component of such hardware is a measurement device, i.e., a quantum detector that is used to determine the outcome of a computation. The act of measurement in quantum mechanics, however, is naturally invasive as the measurement apparatus becomes entangled with the system that it observes. This always leads to a disturbance in the observed system, a phenomenon called quantum measurement backaction, which should solely lead to the collapse of the quantum wave function and the physical realization of the measurement postulate of quantum mechanics. Here we demonstrate that backaction can fundamentally change the quantum system through the detection process. For quantum information processing, this means that the readout alters the system in such a way that a faulty measurement outcome is obtained. Specifically, we report a backaction-induced population switching, where the bare presence of weak, nonprojective measurements by an adjacent charge sensor inverts the electronic charge configuration of a semiconductor double quantum dot system. The transition region grows with measurement strength and is suppressed by temperature, in excellent agreement with our coherent quantum backaction model. Our result exposes backaction channels that appear at the interplay between the detector and the system environments, and opens new avenues for controlling and mitigating backaction effects in future quantum technologies.
The current revolution in quantum technologies relies on the ability to isolate, coherently control, and measure the state of quantum systems. The act of measurement in quantum mechanics, however, is naturally invasive as the measurement apparatus becomes entangled with the system that it observes. Even for ideal detectors, the measurement outcome always leads to a disturbance in the observed system, a phenomenon called quantum measurement backaction. Here we report a profound change in the many-body properties of the measured system due to quantum measurements. We observe this backaction-induced transition in a mesoscopic double quantum-dot in the Coulomb-blockade regime, where we switch the electron population through measurement with a charge sensor dot. Our finding showcases the important changes in behaviour that can arise due to quantum detectors, which are ubiquitous in quantum technologies.
A sensitive technique for the readout of the state of a qubit is based on the measurement of the conductance through a proximal sensor quantum dot (SQD). Here, we theoretically study the coherent backaction of such a measurement on a coupled SQD-charge-qubit system. We derive Markovian kinetic equations for the ensemble-averaged state of the SQD-qubit system, expressed in the coupled dynamics of two charge-state occupations of the SQD and two qubit isospin vectors, one for each SQD charge state. We find that aside from introducing dissipation, the detection also renormalizes the coherent evolution of the SQD-qubit system. Basically, if the electron on the detector has time to probe the qubit, then it also has time to fluctuate and thereby renormalize the system parameters. In particular, this induces torques on the qubit isospins, similar to the spin torque generated by the spintronic exchange field in noncollinear spin-valve structures. Second, we show that for a consistent description of the detection, one must also include the renormalization effects in the next-to-leading order in the electron tunneling rates, especially at the point of maximal sensitivity of the detector. Although we focus on a charge-qubit model, our findings are generic for qubit readout schemes that are based on spin-to-charge conversion using a quantum dot detector. Furthermore, our study of the stationary current through the SQD, a test measurement verifying that the qubit couples to the detector current, already reveals various significant effects of the isospin torques on the qubit. Our kinetic equations provide a starting point for further studies of the time evolution in charge-based qubit readout. Finally, we provide a rigorous sum rule that constrains such approximate descriptions of the qubit isospin dynamics and show that it is obeyed by our kinetic equations.
We theoretically investigate the backaction of a sensor quantum dot with strong local Coulomb repulsion on the transient dynamics of a qubit that is probed capacitively. We show that the measurement backaction induced by the noise of electron cotunneling through the sensor is surprisingly mitigated by the recently identified coherent backaction [M. Hell, M. R. Wegewijs, and D. P. DiVincenzo, Phys. Rev. B 89, 195405 (2014)] arising from quantum fluctuations. This indicates that a sensor with quantized states may be switched off better than naively expected. This renormalization effect is missing in semiclassical stochastic fluctuator models and typically also in Born-Markov approaches, which try to avoid the calculation of the nonstationary, nonequilibrium state of the qubit plus sensor. Technically, we integrate out the current-carrying electrodes to obtain kinetic equations for the joint, nonequilibrium detector-qubit dynamics. We show that the sensor current response, level renormalization, cotunneling broadening, and leading non-Markovian corrections always appear together and cannot be turned off individually in an experiment or ignored theoretically. We analyze the backaction on the reduced qubit state---capturing the full non-Markovian effects imposed by the sensor quantum dot on the qubit---by applying a Liouville-space decomposition into quasistationary and rapidly decaying modes. Importantly, the sensor cannot be eliminated completely even in the simplest high-temperature, weak-measurement limit since the qubit state experiences an initial slip depending on the initial preparation of qubit plus sensor quantum dot. The slip persists over many qubit cycles, i.e., also on the time scale of the qubit decoherence induced by the backaction. A quantum-dot sensor can thus not be modeled as usual as a ``black box'' without accounting for its dynamical variables; it is part of the quantum circuit. We furthermore find that the Bloch vector relaxes (rate 1/T1) along an axis that is not orthogonal to the plane in which the Bloch vector dephases (rate 1/T2), blurring the notions of relaxation and dephasing times. Moreover, the precessional motion of the Bloch vector is distorted into an ellipse in the tilted dephasing plane.
We investigate a tunnel contact coupled to a double quantum dot (DQD) and employed as a charge monitor for the latter. We consider both the classical limit and the quantum regime. In the classical case, we derive measurement correlations from conditional probabilities, yielding quantitative statements about the parameter regime in which the detection scheme works well. Moreover, we demonstrate that not only the DQD occupation but also the corresponding current may strongly correlate with the detector current. The quantum-mechanical solution, obtained with a Bloch-Redfield master equation, shows that the backaction of the measurement tends to localize the DQD electrons, and thus significantly reduces the DQD current. Moreover, it provides the effective parameters of the classical treatment. It turns out that already the classical description is adequate for most operating regimes.