Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2607.07614

Multi-stage Quantum Amplifier Readout Chain

Logan Howe, Andrea Giachero, Michael Vissers, Corwin Shiu, Shannon Duff, Jason Austermann, Johannes Hubmayr, Joel Ullom

quant-phSubmitted Jul 8, 2026• Announced Jul 9, 2026• 0 citations
arXivHTMLPDF

Abstract

Multi-stage cryogenic readout chains with a wide bandwidth and added noise within a few quanta of the quantum limit are frequently constructed using traveling-wave parametric amplifiers (TWPAs) as the first stage, and a semiconductor amplifier as the second stage. Unfortunately for highly-scaled superconducting detector arrays, or quantum information systems, and space-based observatories, the power dissipation of the semiconductor amplifier becomes problematic from the perspective of available cryogenic cooling power at \mbox{3~K to 4~K}. Here we demonstrate a readout chain based on a two-stage kinetic inductance TWPA (KTWPA). This quantum-amplifier-based-readout-chain (QARC) provides sufficient gain that a cryogenic semiconductor follow-on amplifier can be eliminated without degradation of the system noise. In this way, the QARC dissipates approximately three orders of magnitude less power than readout chains containing semiconductor amplifiers while adding noise of less than 2~quanta over a 1~GHz bandwidth. In addition, by leveraging the high power handling of kinetic inductance technology, the QARC maintains an input compression point of -93~dBm, which exceeds that of many contemporary Josephson-junction-based parametric amplifiers.

Related papers

A 4–8 GHz kinetic inductance traveling-wave parametric amplifier using four-wave mixing with near quantum-limited noise performance

Farzad Faramarzi, Ryan Stephenson, Sasha Sypkens +3 more

Kinetic inductance traveling-wave parametric amplifiers (KI-TWPAs) have a wide instantaneous bandwidth with a near quantum-limited noise performance and a relatively high dynamic range. Because of this, they are suitable readout devices for cryogenic detectors and superconducting qubits and have a variety of applications in quantum sensing. This work discusses the design, fabrication, and performance of a KI-TWPA based on four-wave mixing in a NbTiN microstrip transmission line. This device amplifies a signal band from 4 to 8 GHz without contamination from image tones, which are produced in a separate higher frequency band. The 4–8 GHz band is commonly used to read out cryogenic detectors, such as microwave kinetic inductance detectors and Josephson junction-based qubits. We report a measured maximum gain of over 20 dB using four-wave mixing with a 1 dB gain compression point of −58 dBm at 15 dB of gain over that band. The bandwidth and peak gain are tunable by adjusting the pump-tone frequency and power. Using a Y-factor method, we measure an amplifier-added noise of 0.5 ≤ Nadded ≤ 1.5 photons from 4.5 to 8 GHz.

arXiv:2402.11751•APL Quantum•Jul 11, 2024•25 citations

Operation of Unshielded Kinetic-Inductance Traveling-Wave Parametric Amplifiers in Multi-Tesla Fields

C. Boutan, E. Lentz, Corwin Shiu +12 more

Cryogenic parametric amplifiers are used to amplify radio-frequency signals for a range of applications in basic and applied science. Both Josephson Parametric Amplifiers and Josephson Traveling-Wave Parametric Amplifiers have been used as first-stage amplifiers enabling readout chains operating within a few quanta of the quantum limit. However, these devices are highly sensitive to magnetic fields, having critical current suppressed by the Fraunhofer effect, requiring substantial field-free zones. In a dark matter axion search experiment, axions convert to detectable microwave photons in the presence of a strong magnetic field, necessitating amplifiers that can reliably operate close to these environments. Kinetic-inductance Traveling-Wave Parametric Amplifiers (KTWPAs) may be the ideal candidate for this type of application having high critical magnetic field of the materials used throughout their construction. In this letter we demonstrate that KTWPAs can provide high gain (>20dB) over a multi-GHz bandwidth in spite of from multiple exposures to multi-Tesla fields. Further, we explore operational characteristics of these devices under harsh conditions as a function of overall field strength, device orientation within the field, applied bias current, and pump power & frequency. In so doing, we find KTWPA gain vanishes in devices oriented perpendicularly to a field of 0.02T, but gain values >10dB are achievable in fields over 1T when oriented near~parallel to the device plane, with peak gain achieved with an applied 0.25T to 0.5T field. It is our expectation that KTWPAs will expand the accessibility of quantum-limited RF measurements in the presence of Tesla-scale fields.

arXiv:2608.25328•Aug 26, 2026•0 citations

Compact Superconducting Kinetic Inductance Traveling Wave Parametric Amplifiers With On-Chip rf Components

Logan A. Howe, Andrea Giachero, Michael R. Vissers +4 more

Quantum computing systems and fundamental physics experiments using superconducting technologies frequently require signal amplification chains operating near the quantum limit of added noise. Both Josephson parametric amplifiers (JPAs) and traveling wave parametric amplifiers (TWPAs) have been used as first-stage amplifiers to enable readout chains operating within a few quanta or less of the quantum limit. These devices are also presently entering the commercial industry. However, nearly all demonstrations and existing products require bulky external microwave components for interconnection and application of requisite biases. These components – cabling interconnects, bias tees, directional couplers, and diplexers – increase the overall amplifier footprint, installation complexity, and reduce already limited available cryogenic volumes. Additionally, these components introduce loss and reflections which impact the measurement efficiency and readout system noise performance; thus making it more difficult to operate near the quantum limit. Here we present the design and validation of microfabricated bias tees and directional couplers for operating three-wave mixing kinetic inductance TWPAs (KITs). We report the performance of KITs integrated with the microfabricated rf components. Using these devices we demonstrate reduction in the amplifier installation footprint by a factor of nearly five and elimination of all external, lossy microwave components previously required to operate a KIT. Our device displays a 2.8 GHz 3 dB bandwidth with a median true gain of 17.5 dB and median system noise of 3.4 quanta. These efforts represent the first full integration of all rf components mandatory for TWPA operation on-chip. Our results mark significant progress towards the miniaturization and simplification of parametric amplifier setups and will aid in their more widespread applicability.

arXiv:2503.03608•IEEE Transactions on Applied Superconductivity•Mar 21, 2025•8 citations

Measurable Improvement in Multi-Qubit Readout Using a Kinetic Inductance Traveling Wave Parametric Amplifier

Manuel A. Castellanos-Beltran, Logan A. Howe, Andrea Giachero +4 more

Increasing the size and complexity of quantum information systems requires highly-multiplexed readout architectures, as well as amplifier chains operating near the quantum limit (QL) of added noise. While documented prior efforts in KI-TWPA integration in quantum systems are scarce, in this work we demonstrate integration of a KI-TWPA with a multiplexed-qubit device. To quantify the system noise improvement we perform an ac Stark shift calibration to precisely determine noise power levels on-chip (at each cavity's reference plane) and the total system gain. We then characterize the qubit state measurement fidelity and the corresponding signal-to-noise ratio (SNR). To conduct the most faithful measurement of the benefits offered by the KI-TWPA we perform these measurements for readout chains where the high electron mobility transistor (HEMT) amplifier is the first-stage amplifier (FSA) – with none of the external hardware required to operate the KI-TWPA – and with the KI-TWPA as the FSA. While some readout cavities fall outside the KI-TWPA bandwidth, for those inside the bandwidth we demonstrate a maximum improvement in the state measurement SNR by a factor of 1.45, and increase the fidelity from 96.2% to 97.8%. These measurements demonstrate a system noise below 5 quantareferenced on-chipand we bound the KI-TWPA excess noise to be below 4 quanta for the six cavities inside its bandwidth. These results show a promising path forward for realizing quantum-limited readout chains in large qubit systems using a single parametric amplifier.

arXiv:2501.01185•IEEE Transactions on Applied Superconductivity•Jan 2, 2025•4 citations

Kinetic Inductance Traveling Wave Parametric Amplifiers Near the Quantum Limit: Methodology and Characterization

Logan A. Howe, Andrea Giachero, Michael R. Vissers +7 more

We present a detailed simulation and design framework for realizing traveling wave parametric amplifiers (TWPAs) using the nonlinear kinetic inductance of disordered superconductors -- in our case niobium-titanium-nitride (NbTiN). These kinetic inductance TWPAs (KITs) operate via three-wave mixing (3WM) to achieve high broadband gain and near-quantum-limited (nQL) noise. Representative fabricated devices -- realized using an inverted microstrip (IMS), dispersion-engineered, artificial transmission line -- demonstrate power gains above 25 dB, bandwidths beyond 3 GHz, and achieve ultimate system noise levels of 1.1 quanta even when operated with no magnetic shielding. These performance metrics are competitive with state-of-the-art Josephson-junction-based TWPAs but involve simpler fabrication and able to providing three orders of magnitude higher dynamic range ($IIP_1 = -68$ dBm, $IIP_3 = -55$ dBm), and high magnetic field resilience -- making KITs an attractive technology for highly multiplexed readout of quantum information and superconducting detector systems.

arXiv:2507.07706•Jul 10, 2025•0 citations

Detector Array Readout with Traveling Wave Amplifiers

Andrea Giachero, C. Barone, M. Borghesi +35 more

Abstract Reducing noise to the quantum limit over a large bandwidth is a fundamental requirement for future applications operating at millikelvin temperatures, such as the neutrino mass measurement, the next-generation X-ray observatory, the CMB measurement, the dark matter and axion detection, and the rapid high-fidelity readout of superconducting qubits. The read out sensitivity of arrays of microcalorimeter detectors, resonant axion-detectors, and qubits, is currently limited by the noise temperature and bandwidth of the cryogenic amplifiers. The Detector Array Readout with Traveling Wave Amplifiers project has the goal of developing high-performing innovative traveling wave parametric amplifiers with a high gain, a high saturation power, and a quantum-limited or nearly quantum-limited noise. The practical development follows two different promising approaches, one based on the Josephson junctions and the other one based on the kinetic inductance of a high-resistivity superconductor. In this contribution, we present the aims of the project, the adopted design solutions and preliminary results from simulations and measurements.

arXiv:2111.01512•Journal of Low Temperature Physics•Aug 12, 2022•17 citations
Multi-stage cryogenic readout chains with a wide bandwidth and added noise within a few quanta of the quantum limit are frequently constructed using traveling-wave parametric amplifiers (TWPAs) as the first stage, and a semiconductor amplifier as the second stage. Unfortunately for highly-scaled superconducting detector arrays, or quantum information systems, and space-based observatories, the power dissipation of the semiconductor amplifier becomes problematic from the perspective of available cryogenic cooling power at \mbox{3K to 4K}. Here we demonstrate a readout chain based on a two-stage kinetic inductance TWPA (KTWPA). This quantum-amplifier-based-readout-chain (QARC) provides sufficient gain that a cryogenic semiconductor follow-on amplifier can be eliminated without degradation of the system noise. In this way, the QARC dissipates approximately three orders of magnitude less power than readout chains containing semiconductor amplifiers while adding noise of less than 2quanta over a 1GHz bandwidth. In addition, by leveraging the high power handling of kinetic inductance technology, the QARC maintains an input compression point of -93~dBm, which exceeds that of many contemporary Josephson-junction-based parametric amplifiers.
Kinetic inductance traveling-wave parametric amplifiers (KI-TWPAs) have a wide instantaneous bandwidth with a near quantum-limited noise performance and a relatively high dynamic range. Because of this, they are suitable readout devices for cryogenic detectors and superconducting qubits and have a variety of applications in quantum sensing. This work discusses the design, fabrication, and performance of a KI-TWPA based on four-wave mixing in a NbTiN microstrip transmission line. This device amplifies a signal band from 4 to 8 GHz without contamination from image tones, which are produced in a separate higher frequency band. The 4–8 GHz band is commonly used to read out cryogenic detectors, such as microwave kinetic inductance detectors and Josephson junction-based qubits. We report a measured maximum gain of over 20 dB using four-wave mixing with a 1 dB gain compression point of −58 dBm at 15 dB of gain over that band. The bandwidth and peak gain are tunable by adjusting the pump-tone frequency and power. Using a Y-factor method, we measure an amplifier-added noise of 0.5 ≤ Nadded ≤ 1.5 photons from 4.5 to 8 GHz.
Cryogenic parametric amplifiers are used to amplify radio-frequency signals for a range of applications in basic and applied science. Both Josephson Parametric Amplifiers and Josephson Traveling-Wave Parametric Amplifiers have been used as first-stage amplifiers enabling readout chains operating within a few quanta of the quantum limit. However, these devices are highly sensitive to magnetic fields, having critical current suppressed by the Fraunhofer effect, requiring substantial field-free zones. In a dark matter axion search experiment, axions convert to detectable microwave photons in the presence of a strong magnetic field, necessitating amplifiers that can reliably operate close to these environments. Kinetic-inductance Traveling-Wave Parametric Amplifiers (KTWPAs) may be the ideal candidate for this type of application having high critical magnetic field of the materials used throughout their construction. In this letter we demonstrate that KTWPAs can provide high gain (>20dB) over a multi-GHz bandwidth in spite of from multiple exposures to multi-Tesla fields. Further, we explore operational characteristics of these devices under harsh conditions as a function of overall field strength, device orientation within the field, applied bias current, and pump power & frequency. In so doing, we find KTWPA gain vanishes in devices oriented perpendicularly to a field of 0.02T, but gain values >10dB are achievable in fields over 1T when oriented near~parallel to the device plane, with peak gain achieved with an applied 0.25T to 0.5T field. It is our expectation that KTWPAs will expand the accessibility of quantum-limited RF measurements in the presence of Tesla-scale fields.
Quantum computing systems and fundamental physics experiments using superconducting technologies frequently require signal amplification chains operating near the quantum limit of added noise. Both Josephson parametric amplifiers (JPAs) and traveling wave parametric amplifiers (TWPAs) have been used as first-stage amplifiers to enable readout chains operating within a few quanta or less of the quantum limit. These devices are also presently entering the commercial industry. However, nearly all demonstrations and existing products require bulky external microwave components for interconnection and application of requisite biases. These components – cabling interconnects, bias tees, directional couplers, and diplexers – increase the overall amplifier footprint, installation complexity, and reduce already limited available cryogenic volumes. Additionally, these components introduce loss and reflections which impact the measurement efficiency and readout system noise performance; thus making it more difficult to operate near the quantum limit. Here we present the design and validation of microfabricated bias tees and directional couplers for operating three-wave mixing kinetic inductance TWPAs (KITs). We report the performance of KITs integrated with the microfabricated rf components. Using these devices we demonstrate reduction in the amplifier installation footprint by a factor of nearly five and elimination of all external, lossy microwave components previously required to operate a KIT. Our device displays a 2.8 GHz 3 dB bandwidth with a median true gain of 17.5 dB and median system noise of 3.4 quanta. These efforts represent the first full integration of all rf components mandatory for TWPA operation on-chip. Our results mark significant progress towards the miniaturization and simplification of parametric amplifier setups and will aid in their more widespread applicability.
Increasing the size and complexity of quantum information systems requires highly-multiplexed readout architectures, as well as amplifier chains operating near the quantum limit (QL) of added noise. While documented prior efforts in KI-TWPA integration in quantum systems are scarce, in this work we demonstrate integration of a KI-TWPA with a multiplexed-qubit device. To quantify the system noise improvement we perform an ac Stark shift calibration to precisely determine noise power levels on-chip (at each cavity's reference plane) and the total system gain. We then characterize the qubit state measurement fidelity and the corresponding signal-to-noise ratio (SNR). To conduct the most faithful measurement of the benefits offered by the KI-TWPA we perform these measurements for readout chains where the high electron mobility transistor (HEMT) amplifier is the first-stage amplifier (FSA) – with none of the external hardware required to operate the KI-TWPA – and with the KI-TWPA as the FSA. While some readout cavities fall outside the KI-TWPA bandwidth, for those inside the bandwidth we demonstrate a maximum improvement in the state measurement SNR by a factor of 1.45, and increase the fidelity from 96.2% to 97.8%. These measurements demonstrate a system noise below 5 quantareferenced on-chipand we bound the KI-TWPA excess noise to be below 4 quanta for the six cavities inside its bandwidth. These results show a promising path forward for realizing quantum-limited readout chains in large qubit systems using a single parametric amplifier.
We present a detailed simulation and design framework for realizing traveling wave parametric amplifiers (TWPAs) using the nonlinear kinetic inductance of disordered superconductors -- in our case niobium-titanium-nitride (NbTiN). These kinetic inductance TWPAs (KITs) operate via three-wave mixing (3WM) to achieve high broadband gain and near-quantum-limited (nQL) noise. Representative fabricated devices -- realized using an inverted microstrip (IMS), dispersion-engineered, artificial transmission line -- demonstrate power gains above 25 dB, bandwidths beyond 3 GHz, and achieve ultimate system noise levels of 1.1 quanta even when operated with no magnetic shielding. These performance metrics are competitive with state-of-the-art Josephson-junction-based TWPAs but involve simpler fabrication and able to providing three orders of magnitude higher dynamic range (IIP1=−68IIP_1 = -68IIP1​=−68 dBm, IIP3=−55IIP_3 = -55IIP3​=−55 dBm), and high magnetic field resilience -- making KITs an attractive technology for highly multiplexed readout of quantum information and superconducting detector systems.
Abstract Reducing noise to the quantum limit over a large bandwidth is a fundamental requirement for future applications operating at millikelvin temperatures, such as the neutrino mass measurement, the next-generation X-ray observatory, the CMB measurement, the dark matter and axion detection, and the rapid high-fidelity readout of superconducting qubits. The read out sensitivity of arrays of microcalorimeter detectors, resonant axion-detectors, and qubits, is currently limited by the noise temperature and bandwidth of the cryogenic amplifiers. The Detector Array Readout with Traveling Wave Amplifiers project has the goal of developing high-performing innovative traveling wave parametric amplifiers with a high gain, a high saturation power, and a quantum-limited or nearly quantum-limited noise. The practical development follows two different promising approaches, one based on the Josephson junctions and the other one based on the kinetic inductance of a high-resistivity superconductor. In this contribution, we present the aims of the project, the adopted design solutions and preliminary results from simulations and measurements.