Phase-Sensitive Crystal-Edge Effects in Linear Optical Parametric Oscillators: Why Nominally Identical Squeezers Behave Differently

Jonas Junker, Donghwa Lee, Reda Louahaj, Oscar Cordero, Romain Brunel, Jens A. H. Nielsen, Ulrik L. Andersen, Jonas S. Neergaard-Nielsen

quant-phSubmitted May 29, 2026• Announced Jun 2, 2026• 0 citations
arXivHTMLPDF

Abstract

Efficient and reproducible squeezed-light sources are essential for quantum information processing and precision metrology. Compact linear standing-wave optical parametric oscillators (OPOs) are attractive because they combine low optical loss, low pump-power requirements, and large longitudinal mode spacing. In doubly resonant cavities, however, the nonlinear interaction is not determined solely by bulk phase matching: forward- and backward-generated fields recombine coherently, making the effective gain sensitive to crystal-edge termination, wavelength-dependent coating phases, and the cavity resonance condition. Here, we show that these microscopic phase contributions can produce large threshold variations between nominally similar OPOs. We combine double-pass second-harmonic generation with OPO threshold measurements to extract the relevant crystal-cavity phases and analyse three linear OPO systems. The observed devices exhibit threshold variations of up to nearly six-fold, traced to the phase-dependent nonlinear-gain envelope at accessible doubly resonant operating points. Our results establish a phase-aware framework for compact linear OPOs and provide design guidelines for reproducible low-threshold squeezed-light sources in scalable photonic quantum systems.

Comments
10 pages, 9 figures

Related papers

Design of optical parametric cavity for broadband squeezed light field

Junping Wang, Wenhui Zhang, Ruixin Li +3 more

The field of squeezed state is an important quantum resource in the study of quantum optics. In the application of quantum information, the spectrum bandwidth of the squeezed light field is an important index to limit the information transmission capacity. Currently, the optical parametric oscillator (OPO) is one of the most efficient ways to generate high squeezed non-classical optical fields. In this paper, the degenerate singly-resonant and doubly-resonant OPO structures are introduced. Both OPOs are composed of concave mirrors and periodically poled potassium titanyl phosphate crystals (PPKTP). The length of PPKTP crystal is 10 mm. The curvature radius of the curved surface is 12 mm, and it has high reflectivity at 1550 nm and 775 nm. The plane surface is coated with anti-reflection coating. The air gap length is 21 mm. The concave mirror is an output coupling mirror, and its radius of curvature is 25 mm. In the singly-resonant OPO, only the signal light resonates in the cavity, and the pump light passes through the nonlinear crystal twice and then outputs out of the cavity. The reflectivity of OPO output coupling mirror to the wavelength of 1550 nm is 88%. The linewidth of the corresponding fundamental frequency wave is 77.4 MHz. For doubly-resonant OPO, both the signal light and the pump light resonate simultaneously in the cavity. The reflectivity of OPO output coupling mirror to 1550 nm and 775 nm is 85% and 97.5%, respectively. The linewidth of the corresponding fundamental frequency wave and harmonic is 97.1 MHz and 15.6 MHz, respectively. Then the threshold of OPO is calculated. The threshold pump power of OPO increases with signal light transmittance increasing, but the threshold value of doubly-resonant OPO is obviously smaller than that of singly-resonant OPO. After that, the variation of the squeezing bandwidth of the squeezed light field generated by OPO with the transmittance of the signal is analyzed. Finally, we complete the design of quantum squeezer with low threshold (18 mW), broadband (84.2 MHz) and high stability (the standard deviation of locking baseline is 0.32 MHz) experimentally. The results show that compared with the singly-resonant optical parametric oscillator, the doubly-resonant cavity has the characteristics of low threshold and high stability, which is more suitable for the preparation and practical application of broadband squeezed light field.

Acta Physica Sinica•Jan 1, 2020•3 citations

Squeezed amplification with cavity detunings: noise behavior

Ke-Xun Sun, Jeffrey H. Shapiro

Optical parametric amplifiers (OPA's) and optical parametric oscillators (OPO's) can exhibit squeezed amplification when an injected signal beam is used to elicit small-signal gain saturation. This paper extends previous work on OPA/OPO noise behavior under signal injection. Doubly resonant and triply resonant, single-ended cavities are considered in the good-cavity limit. Owing to the nonlinear coupling between the signal and idler beams within the cavity, both are sensitive to the detuning of each beam from its respective resonance. Signal and idler output noise spectra are found by linearizing the quantum coupled-mode equations about the classical mean-field solutions. Cavity detunings lead to frequency dependent phase shifts between the low-noise and high-noise quadratures of both the signal and idler beams. Moreover, the phase of the low-noise quadrature need not coincide with that of the corresponding mean field. The resulting large-signal, signal-to-noise ratio improvement afforded by squeezed amplification is therefore sensitive to the cavity detunings. The effects of classical excess noise on the pump beam and the injected signal beam are also considered.

Annual Meeting Optical Society of America•Jan 1, 1992•0 citations

Watt-level single-frequency optical parametric oscillator around 2 µm

Nicola Coluccelli, Giovanni Cichelli, M. Polastri +3 more

A single-frequency optical parametric oscillator (OPO) operating in the wavelength range around 2 µm is reported. The OPO comprises a periodically poled LiNbO 3 (PPLN) crystal for quasi-phase matching and a four-mirror ring-cavity resonant to the signal. The OPO signal and idler are tuned from 1.89 to 2.05 µm and from 2.21 to 2.42 µm, respectively, by changing the crystal temperature. Output powers in excess of 2 W are demonstrated at a pump power of 9 W for both the signal and idler over all of the respective tuning ranges. A detailed characterization of the intensity and frequency noise is presented. The OPO exhibits an integrated intensity noise below 0.1% and a linewidth of ∼58 kHz for an observation time of 1 ms. The reported performance makes this source an ideal candidate for the generation of squeezed light around 2 µm via cascaded second-harmonic generation (SHG) and parametric downconversion (PDC).

Optics Letters•Sep 20, 2024•5 citations

Nonclassical effects in a mode-locked optical parametric oscillator

Robert M. Shelby, M. D. Levenson, Stephen H. Perlmutter

We have constructed a mode-locked optical parametric oscillator (OPO), synchronously pumped by the second harmonic of a continuously mode-locked Nd:YAG laser and based on type II phase matching in a KTP crystal. The two subharmonics (signal and idler waves) are nearly degenerate in frequency but are distinct orthogonal polarization states, and the oscillator is thus a nondegenerate OPO. Above threshold, the intensities of the signal and idler output beams should be highly correlated, as recently demonstrated for a similar single-frequency OPO.1 Ideally, the quantum noise on the corresponding photocurrent difference signal is completely suppressed for frequencies that are small compared to the OPO cavity bandwidth. Since this configuration produces intense light beams with potentially very good noise suppression, it is an important prototype for possible applications, e.g., to spectroscopy. Initial results with our OPO show an excess uncorrelated polarization noise, possibly due to depolarized light scattering in the KTP crystal. When the OPO cavity is stabilized with the signal and idler degenerate in frequency, they can be mixed to form a superposition by manipulating their polarization. When the oscillator is pumped below threshold, a pulsed squeezed vacuum state is produced in two such mixtures.2 When the polarizations are mixed inside the OPO cavity by a Faraday rotator, the backaction evasion necessary for a quantum nondemolition (QND) measurement of one of the field quadratures of an externally injected beam is obtained.3 The pulsed local oscillator used in observing the squeezing or QND effects is derived from the fundamental output of the pump laser. Progress in implementing these experiments with our mode-locked OPO is described as well as possible applications to time-domain measurements with noise below the shot-noise limit.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations

Pump noise in an optical parametric oscillator operated above threshold

K. W. Leong, N. C. Wong, Jeffrey H. Shapiro

A cw optical parametric oscillator (OPO) operated above threshold is of particular interest in current squeezing experiments. Quadrature squeezing in the signal and idler modes and in the pump mode is predicted. Intensity squeezing in the difference intensity of the signal and idler is predicted and has recently been observed.1 We have built a doubly resonant cw OPO with a magnesium oxide- doped lithium niobate crystal that is single-pass-pumped with the 530.9-nm line of a kryptonion laser. Mode hopping instability near degeneracy puts stringent requirements on the frequency stability of the pump laser and the mechanical stability of the OPO cavity. We have oberved such instability near degeneracy and determined the stability requirements for this OPO. Stable operation can be obtained as the OPO is operated away from degeneracy but at a higher threshold. Classically the single-pass pump output is predicted to be clamped at the threshold value so that the OPO in this configuration acts as a pump power limiter. Quantum mechanically, we have found that the pump intensity noise is enhanced. Measurements on the pump intensity noise spectrum in this particular configuration have been made and compared to our theoretical predictions.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations

Generation of squeezed light with a monolithic optical parametric oscillator: Simultaneous achievement of phase matching and cavity resonance by temperature control

Hidehiro Yonezawa, Koyo Nagashima, Akira Furusawa

We generate squeezed state of light at 860 nm with a monolithic optical parametric oscillator. The optical parametric oscillator consists of a periodically poled KTiOPO(4) crystal, both ends of which are spherically polished and mirror-coated. We achieve both phase matching and cavity resonance by controlling only the temperature of the crystal. We observe up to -8.0±0.2 dB of squeezing with the bandwidth of 142 MHz. Our technique makes it possible to drive many monolithic cavities simultaneously by a single laser. Hence our monolithic optical parametric oscillator is quite suitable to continuous-variable quantum information experiments where we need a large number of highly squeezed light beams.

arXiv:1007.2995•Optics Express•Sep 7, 2010•27 citations
Efficient and reproducible squeezed-light sources are essential for quantum information processing and precision metrology. Compact linear standing-wave optical parametric oscillators (OPOs) are attractive because they combine low optical loss, low pump-power requirements, and large longitudinal mode spacing. In doubly resonant cavities, however, the nonlinear interaction is not determined solely by bulk phase matching: forward- and backward-generated fields recombine coherently, making the effective gain sensitive to crystal-edge termination, wavelength-dependent coating phases, and the cavity resonance condition. Here, we show that these microscopic phase contributions can produce large threshold variations between nominally similar OPOs. We combine double-pass second-harmonic generation with OPO threshold measurements to extract the relevant crystal-cavity phases and analyse three linear OPO systems. The observed devices exhibit threshold variations of up to nearly six-fold, traced to the phase-dependent nonlinear-gain envelope at accessible doubly resonant operating points. Our results establish a phase-aware framework for compact linear OPOs and provide design guidelines for reproducible low-threshold squeezed-light sources in scalable photonic quantum systems.
The field of squeezed state is an important quantum resource in the study of quantum optics. In the application of quantum information, the spectrum bandwidth of the squeezed light field is an important index to limit the information transmission capacity. Currently, the optical parametric oscillator (OPO) is one of the most efficient ways to generate high squeezed non-classical optical fields. In this paper, the degenerate singly-resonant and doubly-resonant OPO structures are introduced. Both OPOs are composed of concave mirrors and periodically poled potassium titanyl phosphate crystals (PPKTP). The length of PPKTP crystal is 10 mm. The curvature radius of the curved surface is 12 mm, and it has high reflectivity at 1550 nm and 775 nm. The plane surface is coated with anti-reflection coating. The air gap length is 21 mm. The concave mirror is an output coupling mirror, and its radius of curvature is 25 mm. In the singly-resonant OPO, only the signal light resonates in the cavity, and the pump light passes through the nonlinear crystal twice and then outputs out of the cavity. The reflectivity of OPO output coupling mirror to the wavelength of 1550 nm is 88%. The linewidth of the corresponding fundamental frequency wave is 77.4 MHz. For doubly-resonant OPO, both the signal light and the pump light resonate simultaneously in the cavity. The reflectivity of OPO output coupling mirror to 1550 nm and 775 nm is 85% and 97.5%, respectively. The linewidth of the corresponding fundamental frequency wave and harmonic is 97.1 MHz and 15.6 MHz, respectively. Then the threshold of OPO is calculated. The threshold pump power of OPO increases with signal light transmittance increasing, but the threshold value of doubly-resonant OPO is obviously smaller than that of singly-resonant OPO. After that, the variation of the squeezing bandwidth of the squeezed light field generated by OPO with the transmittance of the signal is analyzed. Finally, we complete the design of quantum squeezer with low threshold (18 mW), broadband (84.2 MHz) and high stability (the standard deviation of locking baseline is 0.32 MHz) experimentally. The results show that compared with the singly-resonant optical parametric oscillator, the doubly-resonant cavity has the characteristics of low threshold and high stability, which is more suitable for the preparation and practical application of broadband squeezed light field.
Optical parametric amplifiers (OPA's) and optical parametric oscillators (OPO's) can exhibit squeezed amplification when an injected signal beam is used to elicit small-signal gain saturation. This paper extends previous work on OPA/OPO noise behavior under signal injection. Doubly resonant and triply resonant, single-ended cavities are considered in the good-cavity limit. Owing to the nonlinear coupling between the signal and idler beams within the cavity, both are sensitive to the detuning of each beam from its respective resonance. Signal and idler output noise spectra are found by linearizing the quantum coupled-mode equations about the classical mean-field solutions. Cavity detunings lead to frequency dependent phase shifts between the low-noise and high-noise quadratures of both the signal and idler beams. Moreover, the phase of the low-noise quadrature need not coincide with that of the corresponding mean field. The resulting large-signal, signal-to-noise ratio improvement afforded by squeezed amplification is therefore sensitive to the cavity detunings. The effects of classical excess noise on the pump beam and the injected signal beam are also considered.
A single-frequency optical parametric oscillator (OPO) operating in the wavelength range around 2 µm is reported. The OPO comprises a periodically poled LiNbO 3 (PPLN) crystal for quasi-phase matching and a four-mirror ring-cavity resonant to the signal. The OPO signal and idler are tuned from 1.89 to 2.05 µm and from 2.21 to 2.42 µm, respectively, by changing the crystal temperature. Output powers in excess of 2 W are demonstrated at a pump power of 9 W for both the signal and idler over all of the respective tuning ranges. A detailed characterization of the intensity and frequency noise is presented. The OPO exhibits an integrated intensity noise below 0.1% and a linewidth of ∼58 kHz for an observation time of 1 ms. The reported performance makes this source an ideal candidate for the generation of squeezed light around 2 µm via cascaded second-harmonic generation (SHG) and parametric downconversion (PDC).
We have constructed a mode-locked optical parametric oscillator (OPO), synchronously pumped by the second harmonic of a continuously mode-locked Nd:YAG laser and based on type II phase matching in a KTP crystal. The two subharmonics (signal and idler waves) are nearly degenerate in frequency but are distinct orthogonal polarization states, and the oscillator is thus a nondegenerate OPO. Above threshold, the intensities of the signal and idler output beams should be highly correlated, as recently demonstrated for a similar single-frequency OPO.1 Ideally, the quantum noise on the corresponding photocurrent difference signal is completely suppressed for frequencies that are small compared to the OPO cavity bandwidth. Since this configuration produces intense light beams with potentially very good noise suppression, it is an important prototype for possible applications, e.g., to spectroscopy. Initial results with our OPO show an excess uncorrelated polarization noise, possibly due to depolarized light scattering in the KTP crystal. When the OPO cavity is stabilized with the signal and idler degenerate in frequency, they can be mixed to form a superposition by manipulating their polarization. When the oscillator is pumped below threshold, a pulsed squeezed vacuum state is produced in two such mixtures.2 When the polarizations are mixed inside the OPO cavity by a Faraday rotator, the backaction evasion necessary for a quantum nondemolition (QND) measurement of one of the field quadratures of an externally injected beam is obtained.3 The pulsed local oscillator used in observing the squeezing or QND effects is derived from the fundamental output of the pump laser. Progress in implementing these experiments with our mode-locked OPO is described as well as possible applications to time-domain measurements with noise below the shot-noise limit.
A cw optical parametric oscillator (OPO) operated above threshold is of particular interest in current squeezing experiments. Quadrature squeezing in the signal and idler modes and in the pump mode is predicted. Intensity squeezing in the difference intensity of the signal and idler is predicted and has recently been observed.1 We have built a doubly resonant cw OPO with a magnesium oxide- doped lithium niobate crystal that is single-pass-pumped with the 530.9-nm line of a kryptonion laser. Mode hopping instability near degeneracy puts stringent requirements on the frequency stability of the pump laser and the mechanical stability of the OPO cavity. We have oberved such instability near degeneracy and determined the stability requirements for this OPO. Stable operation can be obtained as the OPO is operated away from degeneracy but at a higher threshold. Classically the single-pass pump output is predicted to be clamped at the threshold value so that the OPO in this configuration acts as a pump power limiter. Quantum mechanically, we have found that the pump intensity noise is enhanced. Measurements on the pump intensity noise spectrum in this particular configuration have been made and compared to our theoretical predictions.
We generate squeezed state of light at 860 nm with a monolithic optical parametric oscillator. The optical parametric oscillator consists of a periodically poled KTiOPO(4) crystal, both ends of which are spherically polished and mirror-coated. We achieve both phase matching and cavity resonance by controlling only the temperature of the crystal. We observe up to -8.0±0.2 dB of squeezing with the bandwidth of 142 MHz. Our technique makes it possible to drive many monolithic cavities simultaneously by a single laser. Hence our monolithic optical parametric oscillator is quite suitable to continuous-variable quantum information experiments where we need a large number of highly squeezed light beams.