Narrow-linewidth lasers with absolute frequency anchoring are essential for precision metrology, coherent sensing, and emerging quantum technologies beyond laboratory environments. Optical cavities and interferometers provide exceptional short-term spectral purity but lack intrinsic absolute frequency references. Atomic transitions, in contrast, provide stable frequency anchors but offer limited discrimination sensitivity. Recent hybrid approaches have demonstrated the combination of compact optical resonators with atomic references, yet achieving the Hz-level regime remains challenging. Here, we present a hybrid architecture that enables simultaneous realization of Hz-level linewidth and atomic-referenced frequency stability. An external-cavity diode laser is first stabilized to a fiber interferometer to achieve Hz-level spectral purity, while the interferometer is subsequently anchored to an 87Rb D2 transition via modulation transfer spectroscopy to suppress long-term drift and define the laser frequency relative to the atomic transition. This dual-stabilization scheme realizes a compact atomic-referenced laser with a 3.4-Hz linewidth (1-rad integrated-phase method), a minimum fractional frequency stability of 3.4x10-14 at 0.56 s, and 9x10-13 at 100 s. This architecture establishes a practical and scalable route toward compact and field-deployable atomic-referenced narrow-linewidth lasers for precision metrology and quantum technologies.
Narrow-linewidth lasers with absolute frequency anchoring are essential for precision metrology, coherent sensing, and emerging quantum technologies beyond laboratory environments. Optical cavities and interferometers provide exceptional short-term spectral purity but lack intrinsic absolute frequency references. Atomic transitions, in contrast, provide stable frequency anchors but offer limited discrimination sensitivity. Recent hybrid approaches have demonstrated the combination of compact optical resonators with atomic references, yet achieving the Hz-level regime remains challenging. Here, we present a hybrid architecture that enables simultaneous realization of Hz-level linewidth and atomic-referenced frequency stability. An external-cavity diode laser is first stabilized to a fiber interferometer to achieve Hz-level spectral purity, while the interferometer is subsequently anchored to an 87Rb D2 transition via modulation transfer spectroscopy to suppress long-term drift and define the laser frequency relative to the atomic transition. This dual-stabilization scheme realizes a compact atomic-referenced laser with a 3.4-Hz linewidth (1-rad integrated-phase method), a minimum fractional frequency stability of 3.4x10-14 at 0.56 s, and 9x10-13 at 100 s. This architecture establishes a practical and scalable route toward compact and field-deployable atomic-referenced narrow-linewidth lasers for precision metrology and quantum technologies.
Precision atomic and quantum experiments rely on ultra-stable narrow linewidth lasers constructed using table-top ultra-low expansion reference cavities. These experiments often require multiple lasers, operating at different wavelengths, to perform key steps used in state preparation and measurement required in quantum sensing and computing. This is traditionally achieved by disciplining a cavity-stabilized laser to a key atomic transition and then transferring the transition linewidth and stability to other lasers using the same reference cavity in combination with bulk-optic frequency shifting such as acousto-optic modulators. Transitioning such capabilities to a future potentially low-cost photonic-integrated platform will enable a wide range of portable, low power, scalable quantum experiments and applications. Yet, today’s bulk optic approaches pose challenges related to lack of cavity tunability, large free spectral range, and limited photonic integration potential. Here, we address these challenges with demonstration of an agile photonic-integrated 780 nm ultra-high-Q tunable silicon nitride reference cavity that performs multiple critical experimental steps including laser linewidth narrowing, high resolution rubidium spectroscopy, dual-stage stabilization to a rubidium transition, and stability transfer to other lasers. We achieve up to 20 dB of frequency noise reduction at 10 kHz offset, precision spectroscopy over a 250 MHz range, and dual-stage locking to rubidium with an Allan deviation of 8.5 × 10 −12 at 1 s and up to 40 dB frequency noise reduction at 100 Hz frequency offset. We further use the rubidium-disciplined cavity to provide atomic-referenced frequency stability to a second laser and demonstrate multi-wavelength Rydberg electrometry quantum sensing. These results pave the path for integrated, compact, and scalable solutions for quantum sensing, computing, and other atomic and trapped ion applications.
We demonstrate a method to simultaneously suppress the linewidths and stabilize the long-term frequency drifts of both 780-nm and 960-nm lasers to the 10-kHz level. We first use an iodine frequency stabilization laser as a frequency reference to stabilize the length of a tunable high-finesse transfer cavity (THFTC). Then two slave lasers of 780 nm and 960 nm are locked to this THFTC. In this way, the linewidths of slave lasers are suppressed to the order of 10 kHz, which are measured by delayed self-heterodyne measurements. Meanwhile, the long-term frequency drifts are stabilized to be less than 22 kHz for 10 h. With the locked lasers, we realize the coherent Rydberg excitation of a single Rb87 atom and keep the exciting stable and repeatable for 10 h, which is essential for Rydberg-mediated single-atom quantum information processing. This dual-laser frequency stabilization and transfer method can also be used in other high-resolution experiments in atomic physics, precision metrology, and molecular spectroscopy.
We will describe a next-generation active atomic frequency reference based on super-radiant pulses of laser light from the ultra-narrow, 1 mHz linewidth, optical clock transition in an ensemble of cold 87Sr atoms. Light is stimulated from the millihertz linewidth transition by confining an ensemble of laser cooled atoms inside of a high finesse optical cavity. Such a light source has been proposed as a next-generation active atomic frequency reference, with the potential to enable high-precision optical frequency references to be used outside laboratory environments. We achieve a remarkable short term fractional frequency stability, 6.7 × 1016 at 1 s of averaging, absolute accuracy, 2 Hz (4 × 1015 fractional frequency), and high insensitivity to changes in the cavity length that limits the performance of todays more stable lasers. We will also discuss current work on cavity-enhanced dispersive measurements to perform high resolution spectroscopy and atom counting.
Abstract Lasers with high spectral purity can enable a diverse application space, including precision spectroscopy, coherent high‐speed communications, physical sensing, and manipulation of quantum systems. Already, meticulous design and construction of bench Fabry–Perot cavities has made possible dramatic achievements in active laser‐linewidth reduction, predominantly for optical‐atomic clocks. Yet, there is increasing demand for miniaturized laser systems operating with high performance in ambient environments. Here, a compact and robust photonic‐atomic laser comprising a 2.5 centimeter long, 20 000 finesse, monolithic Fabry–Perot cavity integrated with a micromachined rubidium vapor cell is presented. By leveraging the short‐time frequency stability of the cavity and the long‐time frequency stability of atoms, an ultranarrow‐linewidth laser that enables integration for extended measurements is realized. Specifically, the laser supports a fractional‐frequency stability of at an averaging time of 20 millisecond, at 300 second, an integrated linewidth of 25 Hz that results from thermal noise, frequency noise floor as low as 0.06 Hz2 Hz−1, and a passive vibration immunity as low as 10−10 g−1. The present work explores hybrid laser systems with monolithic photonic and atomic packages based on physical design.
Distributed Bragg reflector (DBR) lasers have found promising prospects in quantum sensing, cold atom physics, and precision spectroscopy. However, a broader implementation is challenged by their MHz-scale linewidths and the absence of autonomous atomic resonance alignment. Here, we demonstrate a turnkey 795 nm DBR laser system locked to the Rb 85 D 1 hyperfine transition. Our approach employs a dual-stage architecture: stage 1 utilizes the Faraday anomalous dispersion optical filter (FADOF) with optical feedback, achieving automatic frequency resonance and confinement to the vicinity of the Rb 85 D 1 line, while reducing the 1/ π integral linewidth from 461.8 kHz to 28.8 kHz, and the Lorentzian linewidth from 25.8 kHz to 426.9 Hz. This mechanism is quantitatively investigated using Lang–Kobayashi equations. Stage 2 applies modulation transfer spectroscopy (MTS) to further stabilize the frequency of the optically locked laser, which yields an Allan deviation of 3.29×10 −13 / τ . Our system unlocks DBR lasers’ potential in quantum precision measurements, offering a convenient, compact, low-noise light source for atomic clocks, magnetometers, and gyroscopes.
We demonstrate a straightforward frequency-locking technique that employs external modulation saturation absorption spectroscopy to achieve a high-performance 780 nm laser system. By externally modulating the laser frequency through a fiber electro-optic modulator, this scheme can stabilize multiple transitions of the 87Rb D2 line with excellent performance. Experimental results establish fractional frequency instability of 2.21 × 10-13 at 1 s with a linewidth of 1.46 kHz for the cycling transition 5S1/2(Fg = 2) → 5P3/2(Fe = 3). Notably, we have locked the system to the repumping transition 5S1/2(Fg = 1) → 5P3/2(Fe = 2), achieving a record-low instability of 1.98 × 10-12 at 1 s averaging time. This simplified laser system, featuring exceptional short-term frequency stability and multi-frequency locking capability, serves as a critical subsystem for the compact cold-atom optical clock, enabling advanced precision metrology applications. Furthermore, its metrological performance enables immediate applications in other quantum sensors, such as Rydberg electrometry, atomic magnetometry, and matter-wave interferometry.