Quantum-enhanced interferometry is often discussed in terms of ideal resources and asymptotic scalings, whereas in practice its performance is set by a delicate interplay between losses, state imbalance, and photon number. We address this interplay in a folded Franson interferometer fed with partially entangled N00N states, treating asymmetric losses and tunable input imbalance on equal footing. From exact detection probabilities we obtain closed-form expressions for the fringe visibility and the Fisher information, and show that these two figures of merit respond very differently to imperfections. In particular, we demonstrate that perfect interference contrast can always be recovered by compensating loss asymmetry with an appropriate input imbalance, while the Fisher information generally peaks at a distinct operating point, reflecting the irreducible trade-off between coherence restoration and signal attenuation. By determining the exact optima and benchmarking against single-photon strategies, we identify the critical loss and minimum entanglement required to maintain a genuine quantum advantage over optimized single-photon strategies under identical loss conditions, and establish their scaling with the photon number N . Beyond delineating the fundamental trade-offs between loss, entanglement, and sensitivity, this work establishes a comprehensive theoretical framework that both underpins and extends the experimental demonstration of quantum advantage reported in [1], providing a unified description of the relevant operating regimes.
Quantum-enhanced interferometry is often discussed in terms of ideal resources and asymptotic scalings, whereas in practice its performance is set by a delicate interplay between losses, state imbalance, and photon number. We address this interplay in a folded Franson interferometer fed with partially entangled N00N states, treating asymmetric losses and tunable input imbalance on equal footing. From exact detection probabilities we obtain closed-form expressions for the fringe visibility and the Fisher information, and show that these two figures of merit respond very differently to imperfections. In particular, we demonstrate that perfect interference contrast can always be recovered by compensating loss asymmetry with an appropriate input imbalance, while the Fisher information generally peaks at a distinct operating point, reflecting the irreducible trade-off between coherence restoration and signal attenuation. By determining the exact optima and benchmarking against single-photon strategies, we identify the critical loss and minimum entanglement required to maintain a genuine quantum advantage over optimized single-photon strategies under identical loss conditions, and establish their scaling with the photon number N . Beyond delineating the fundamental trade-offs between loss, entanglement, and sensitivity, this work establishes a comprehensive theoretical framework that both underpins and extends the experimental demonstration of quantum advantage reported in [1], providing a unified description of the relevant operating regimes.
Quantum metrology employs quantum resources to enhance the measurement sensitivity beyond that can be achieved classically. While multiphoton entangled N00N states can in principle beat the shot-noise limit and reach the Heisenberg limit, high N00N states are difficult to prepare and fragile to photon loss which hinders them from reaching unconditional quantum metrological advantages. Here, we combine the idea of unconventional nonlinear interferometers and stimulated emission of squeezed light, previously developed for the photonic quantum computer Jiuzhang, to propose and realize a new scheme that achieves a scalable, unconditional, and robust quantum metrological advantage. We observe a 5.8(1)-fold enhancement above the shot-noise limit in the Fisher information extracted per photon, without discounting for photon loss and imperfections, which outperforms ideal 5-N00N states. The Heisenberg-limited scaling, the robustness to external photon loss, and the ease-of-use of our method make it applicable in practical quantum metrology at a low photon flux regime.
We investigate an optimal distance of two components in an entangled coherent state for quantum phase estimation in lossy interferometry. The optimal distance is obtained by an economical point, representing the quantum Fisher information that we can extract per input energy. Maximizing the formula of the quantum Fisher information over an input mean photon number, we show that, as the losses of the interferometer increase, it can be more beneficial to prepare an initially entangled coherent state that is less entangled. This represents that the optimal distance of the two-mode components decreases with more loss in the interferometry. Under the constraint of the input mean photon number, we obtain that the optimal entangled coherent state is more robust than a separable coherent state, even in a high photon loss rate. The optimal entangled coherent state preserves quantum advantage over the standard interferometric limit of the separable coherent state. We also show that the corresponding optimal measurement requires correlation measurement bases.
We optimize two-mode entangled number states of light in the presence of loss in order to maximize the extraction of the available phase information in an interferometer. Our approach optimizes over the entire available input Hilbert space with no constraints, other than fixed total initial photon number. We optimize to maximize the Fisher information, which is equivalent to minimizing the phase uncertainty. We find that in the limit of zero loss, the optimal state is the maximally path-entangled (so-called N00N) state, for small loss, the optimal state gradually deviates from the N00N state, and in the limit of large loss, the optimal state converges to a generalized two-mode coherent state, with a finite total number of photons. The results provide a general protocol for optimizing the performance of a quantum optical interferometer in the presence of photon loss, with applications to quantum imaging, metrology, sensing, and information processing.
A quantum-enhanced telescope (interferometer) can have significant advantages in precisely measuring the angular position of remote objects through sending out ancillary quantum entanglement pairs alongside the large baselines of telescopes. In principle, the larger the baseline, the higher the expected measurement resolution. However, the well-known major problem of photon transmission loss would drastically undermine the practical application of all quantum-enhanced telescopes and optical interferometers that transmit photons along the baseline, especially for the large baselines required for high angular resolution. Here, we propose a photon-transmission-loss-independent quantum-enhanced interferometer that is robust to the transmission loss and keeps its advantages unchanged given whatever large baseline. This removes the well-known barrier to the practical application of quantum-enhanced telescopes. Moreover, in contrast to the previous results of quantum-entanglement-enhanced telescopes requesting sophisticated resources—perfect single-photon entanglement, photon-number-resolving detectors, or quantum memories—our method requires only threshold detectors and tunable coherent-state or two-mode squeezed-state sources, which are mature technologies nowadays, and it does not need any quantum memory. We demonstrate the high performance of our method using Fisher information. For the phase difference of weak light from a remote star, the high-quality result of Fisher information remains constant under arbitrarily large transmission loss, and hence all the advantageous results and the performance of our method are actually independent of transmission loss.
With the goal of designing interferometers and interferometer sensors, e.g., LADARs with enhanced sensitivity, resolution, and phase estimation, states using quantum entanglement are discussed. These states include N00N states, plain M and M states (PMMSs), and linear combinations of M and M states (LCMMS). Closed form expressions for the optimal detection operators; visibility, a measure of the state’s robustness to loss and noise; a resolution measure; and phase estimate error, are provided in closed form. The optimal resolution for the maximum visibility and minimum phase error are found. For the visibility, comparisons between PMMSs, LCMMS, and N00N states are provided. For the minimum phase error, comparisons between LCMMS, PMMSs, N00N states, separate photon states (SPSs), the shot noise limit (SNL), and the Heisenberg limit (HL) are provided. A representative collection of computational results illustrating the superiority of LCMMS when compared to PMMSs and N00N states is given. It is found that for a resolution 12 times the classical result LCMMS has visibility 11 times that of N00N states and 4 times that of PMMSs. For the same case, the minimum phase error for LCMMS is 10.7 times smaller than that of PMMS and 29.7 times smaller than that of N00N states.
Non-Gaussian operations can reshape the photon statistics of continuous-variable probes, but their metrological advantage is meaningful only when heralding probability and photon-number resources are counted consistently. We compare photon subtraction, photon addition, and photon catalysis as input-side heralding operations in a balanced SU(1,1) interferometer with parity detection. A unified finite-transmissivity map supplies closed conditional moments and the corresponding quantum Fisher information at arbitrary operation order; internal loss is absorbed into a single effective parity observable whose lossless limit recovers the ideal pulled-back measurement. At fixed preparation parameters, single-photon subtraction and addition improve the conditional phase information over the Gaussian reference across most of the high-transmissivity regime, while multi-photon catalysis opens useful low-transmissivity windows. However, when the coherent--squeezed allocation is independently optimized at fixed conditional-probe energy and fixed interferometer gain, the success-weighted Fisher information of all three non-Gaussian operations remains below the optimized Gaussian benchmark. This conclusion is subject to the tested constraints: single-photon operations, a coherent-plus-squeezed-vacuum Gaussian family, fixed gain, and parity readout. Photon catalysis separately generates a conditional branch with high local quantum Fisher information that dark-point parity extracts poorly, identifying a measurement mismatch rather than a state-preparation failure. The result draws a sharp boundary between conditional non-Gaussian enhancement and practically available precision under explicitly stated resource constraints.