Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2602.22498

Stabilization of Rydberg Dissipative Time Crystals Using a Scanning Fabry Perot Interferometer Transfer Lock

Darmindra Arumugam, Brook Feyissa

physics.atom-phquant-phSubmitted Feb 26, 2026• Announced Feb 27, 2026• 0 citations
arXivHTMLPDF

Abstract

Stabilization of laser frequencies is critical for sensitive Rydberg measurements, including in applications such as dissipative time crystal (DTC) dynamics, yet conventional approaches often require complex or costly hardware. We demonstrate a compact, low cost stabilization method using a scanning Fabry Perot interferometer (SFPI) to transfer lock a 960nm coupler laser to an 852nm probe. The lock suppresses coupler multi MHz free running drift and improves the Allan deviation by up to an order of magnitude, reaching <75kHz at 66s. Applied to DTC oscillations using a Rb 2 photon D2 transition, the second harmonic generated 480nm (from 960nm lock) reduces DTC frequency drift from >20kHz to a few kHz and lowers instability by more than an order of magnitude with a minimum Allan deviation of 0.2kHz at <10s. These results establish SFPI-based transfer locking as a practical and accurate approach for scalable multi laser Rydberg experiments requiring long-term stability in a compact and low cost system.

Related papers

Stabilization of Rydberg dissipative time crystals using a scanning Fabry–Pérot interferometer transfer lock

Darmindra D. Arumugam, Brook Feyissa

Stabilization of laser frequencies is critical for sensitive Rydberg measurements, including in applications such as dissipative time-crystal (DTC) dynamics, yet conventional approaches often require complex or costly hardware. We demonstrate a compact, low-cost stabilization method using a scanning Fabry–Pérot interferometer (SFPI) to transfer lock a 960 nm coupler laser to an 852 nm Cs reference laser. The lock suppresses coupler multi-MHz free-running drift and improves the Allan deviation by up to an order of magnitude, reaching <75 kHz at τ ∼ 66 s. Applied to DTC oscillations using a Rb 2-photon D2 transition, the second harmonic generated at 480 nm (from 960 nm lock) reduces DTC frequency drift from >20 kHz to a few kHz and lowers instability by more than an order of magnitude with a minimum Allan deviation of 0.2 kHz at τ < 10 s. These results establish SFPI-based transfer locking as a practical and accurate approach for scalable multi-laser Rydberg experiments that require long-term stability in a compact and low-cost system.

Applied Physics Letters•Mar 9, 2026•1 citation

Fizeau wavemeter stabilized Rydberg dissipative time crystals

Darmindra D. Arumugam

Sustained dissipative time crystal (DTC) oscillations are demonstrated in a room-temperature Rb-87 vapor cell enabled by stabilization of the coupler laser to a Fizeau wavemeter. The ladder scheme employs a 780 nm probe on the D2 transition and a 960 nm coupler (frequency-doubled to 480 nm) driving the 5P3/2→63D3/2 Rydberg transition. The 960 nm coupler, locked via feedback from a commercial Fizeau interferometric wavemeter, achieves frequency stability with Allan deviation <33kHz for τ>10s. This stabilization reproducibly generates DTC oscillations near 31kHz, while free-running operation leads to rapid decay, drift, or low-Q modes. Allan deviation of the DTC oscillation frequency itself confirms ∼20 Hz stability for τ>100s. These results demonstrate that stabilization using a widely available commercial wavemeter satisfies the laser frequency-stability requirements for accessing long-duration Rydberg dissipative time-crystal dynamics.

Optics Continuum•Jan 22, 2026•2 citations

Rydberg-state hopping in a wavemeter-locked dissipative time crystal system

Darmindra D. Arumugam

Rydberg-state hopping is demonstrated in a wavemeter-locked two-photon rubidium system (Rb D2 probe at 780 and 480 nm coupler), enabling rapid and repeatable switching between the 65S1/2 and 63D5/2 states without a high-finesse cavity or frequency-comb stabilization. A Fizeau-interferometer wavemeter provides the error signal for a digital feedback loop that simultaneously stabilizes the coupler and commands discrete Rydberg-state changes. The lock achieves sub-MHz frequency stability and acquisition rates up to 6.5 GHz s−1 (0.4283 GHz engaged in 66 ms), extrapolating to ∼0.93 s for a ∼6 GHz 65S ↔ 63D transition. Time resolved spectra reveal re-emergent dissipative time crystal (DTC) oscillations after each hop, with distinct state-dependent fundamentals and harmonics. This approach addresses the need for dynamically reconfigurable Rydberg-state control for on-resonant multi-band field detection, while the DTC frequency reconfigurability enables adaptive, low-frequency E-field sensing in compact architectures.

arXiv:2603.18055•APL Photonics•May 1, 2026•0 citations

Injection locking of Rydberg dissipative time crystals

Darmindra D. Arumugam

Non-equilibrium Rydberg gases exhibit exotic many-body phases stabilized by the interplay of coherent interactions and dissipation. Strong Rydberg interactions drive sustained limit cycle oscillations, whose robustness, long-range temporal order, and spontaneous time-translation symmetry breaking establish a dissipative time crystal (DTC). Collective self-entrainment in driven ensembles leads to global synchronization and a dominant oscillation frequency. Here, injection locking of a Rydberg DTC is demonstrated using a radio-frequency (RF) electric field that gradually pulls the intrinsic oscillation toward the injected frequency. Above a critical threshold, full synchronization occurs, with the locking bandwidth scaling linearly with RF amplitude. This includes synchronization of higher-order harmonics, revealing entrainment of the system’s nonlinear temporal dynamics. The phenomenon parallels injection locking in classical nonlinear systems, but emerges here in a strongly interacting quantum medium. This approach establishes a new method for stabilizing and controlling time-crystalline temporal order, with applications in precision sensing, quantum metrology, and timekeeping. Non-equilibrium Rydberg gases exhibit unique many-body phases arising from the interplay of coherent interactions and dissipation, yet controlling their temporal order remains challenging. This work demonstrates injection locking of a Rydberg dissipative time crystal using a radio-frequency electric field, achieving full synchronization and revealing dynamical behavior relevant to precision sensing and quantum metrology.

arXiv:2504.16210•Communications Physics•Mar 18, 2026•7 citations

Aircraft-level vibration effects on hyperfine laser locks for Rydberg electric-field sensing

Darmindra D. Arumugam, Brook Feyissa, Devin Willey

We present a subsystem-isolated study of aircraft-level vibration coupling to a hyperfine laser lock and its propagation to a two-photon Rydberg superheterodyne RF sensor. Here, the probe laser is stabilized to an atomic hyperfine transition, and RF electric fields are detected via a Rydberg-atom superheterodyne process that down-converts the signal to an optical readout. A compact Doppler-free saturated-absorption spectroscopy (SAS) module probing the 87 Rb 5 S 1/2 →5 P 3/2 hyperfine manifold was driven to NASA DC-8 in-flight vibration levels (<2kHz) to investigate the effects of vibration on the stabilization of a 780 nm laser. The stabilized 780 nm probe was combined with a 480 nm coupling laser to excite a room-temperature Rydberg sensor to the 63 D 5/2 state and driven for the RF superheterodyne detection via a ∼8.35GHz local oscillator coupling to the 64 P 3/2 state (RF 100 kHz detuned). Under nominal PID settings, vibration introduced low-frequency noise but did not cause the laser to unlock nor did it degrade the atomic RF readout. Probe wavemeter Allan deviations remain ⟨60kHzat τ ⟩20s at with and without vibration, indicating no loss of lock or MHz-scale drift. Independent frequency-noise-density measurements show no measurable difference between vibration and no-vibration conditions under nominal PID settings. The Rydberg spectrum showed <10% RF-amplitude deviation and a sensitivity of ∼1.5×10 −5 Vm −1 Hz −1/2 . Increasing integral gain by >10 3 transferred vibration noise to the servo, elevating low-frequency noise in the atomic RF spectrum, but with no measurable degradation of the RF sensing at 100 kHz detuning.

Applied Optics•May 1, 2026•0 citations

Stabilizing dual laser with a tunable high-finesse transfer cavity for single-atom Rydberg excitation

Yong Zeng, Kunpeng Wang, Yangyang Liu +5 more

We demonstrate a method to simultaneously suppress the linewidths and stabilize the long-term frequency drifts of both 780-nm and 960-nm lasers to the 10-kHz level. We first use an iodine frequency stabilization laser as a frequency reference to stabilize the length of a tunable high-finesse transfer cavity (THFTC). Then two slave lasers of 780 nm and 960 nm are locked to this THFTC. In this way, the linewidths of slave lasers are suppressed to the order of 10 kHz, which are measured by delayed self-heterodyne measurements. Meanwhile, the long-term frequency drifts are stabilized to be less than 22 kHz for 10 h. With the locked lasers, we realize the coherent Rydberg excitation of a single Rb87 atom and keep the exciting stable and repeatable for 10 h, which is essential for Rydberg-mediated single-atom quantum information processing. This dual-laser frequency stabilization and transfer method can also be used in other high-resolution experiments in atomic physics, precision metrology, and molecular spectroscopy.

Journal of the Optical Society of America B•Feb 1, 2018•25 citations
Stabilization of laser frequencies is critical for sensitive Rydberg measurements, including in applications such as dissipative time crystal (DTC) dynamics, yet conventional approaches often require complex or costly hardware. We demonstrate a compact, low cost stabilization method using a scanning Fabry Perot interferometer (SFPI) to transfer lock a 960nm coupler laser to an 852nm probe. The lock suppresses coupler multi MHz free running drift and improves the Allan deviation by up to an order of magnitude, reaching <75kHz at 66s. Applied to DTC oscillations using a Rb 2 photon D2 transition, the second harmonic generated 480nm (from 960nm lock) reduces DTC frequency drift from >20kHz to a few kHz and lowers instability by more than an order of magnitude with a minimum Allan deviation of 0.2kHz at <10s. These results establish SFPI-based transfer locking as a practical and accurate approach for scalable multi laser Rydberg experiments requiring long-term stability in a compact and low cost system.
Stabilization of laser frequencies is critical for sensitive Rydberg measurements, including in applications such as dissipative time-crystal (DTC) dynamics, yet conventional approaches often require complex or costly hardware. We demonstrate a compact, low-cost stabilization method using a scanning Fabry–Pérot interferometer (SFPI) to transfer lock a 960 nm coupler laser to an 852 nm Cs reference laser. The lock suppresses coupler multi-MHz free-running drift and improves the Allan deviation by up to an order of magnitude, reaching <75 kHz at τ ∼ 66 s. Applied to DTC oscillations using a Rb 2-photon D2 transition, the second harmonic generated at 480 nm (from 960 nm lock) reduces DTC frequency drift from >20 kHz to a few kHz and lowers instability by more than an order of magnitude with a minimum Allan deviation of 0.2 kHz at τ < 10 s. These results establish SFPI-based transfer locking as a practical and accurate approach for scalable multi-laser Rydberg experiments that require long-term stability in a compact and low-cost system.
Sustained dissipative time crystal (DTC) oscillations are demonstrated in a room-temperature Rb-87 vapor cell enabled by stabilization of the coupler laser to a Fizeau wavemeter. The ladder scheme employs a 780 nm probe on the D2 transition and a 960 nm coupler (frequency-doubled to 480 nm) driving the 5P3/2→63D3/2 Rydberg transition. The 960 nm coupler, locked via feedback from a commercial Fizeau interferometric wavemeter, achieves frequency stability with Allan deviation <33kHz for τ>10s. This stabilization reproducibly generates DTC oscillations near 31kHz, while free-running operation leads to rapid decay, drift, or low-Q modes. Allan deviation of the DTC oscillation frequency itself confirms ∼20 Hz stability for τ>100s. These results demonstrate that stabilization using a widely available commercial wavemeter satisfies the laser frequency-stability requirements for accessing long-duration Rydberg dissipative time-crystal dynamics.
Rydberg-state hopping is demonstrated in a wavemeter-locked two-photon rubidium system (Rb D2 probe at 780 and 480 nm coupler), enabling rapid and repeatable switching between the 65S1/2 and 63D5/2 states without a high-finesse cavity or frequency-comb stabilization. A Fizeau-interferometer wavemeter provides the error signal for a digital feedback loop that simultaneously stabilizes the coupler and commands discrete Rydberg-state changes. The lock achieves sub-MHz frequency stability and acquisition rates up to 6.5 GHz s−1 (0.4283 GHz engaged in 66 ms), extrapolating to ∼0.93 s for a ∼6 GHz 65S ↔ 63D transition. Time resolved spectra reveal re-emergent dissipative time crystal (DTC) oscillations after each hop, with distinct state-dependent fundamentals and harmonics. This approach addresses the need for dynamically reconfigurable Rydberg-state control for on-resonant multi-band field detection, while the DTC frequency reconfigurability enables adaptive, low-frequency E-field sensing in compact architectures.
Non-equilibrium Rydberg gases exhibit exotic many-body phases stabilized by the interplay of coherent interactions and dissipation. Strong Rydberg interactions drive sustained limit cycle oscillations, whose robustness, long-range temporal order, and spontaneous time-translation symmetry breaking establish a dissipative time crystal (DTC). Collective self-entrainment in driven ensembles leads to global synchronization and a dominant oscillation frequency. Here, injection locking of a Rydberg DTC is demonstrated using a radio-frequency (RF) electric field that gradually pulls the intrinsic oscillation toward the injected frequency. Above a critical threshold, full synchronization occurs, with the locking bandwidth scaling linearly with RF amplitude. This includes synchronization of higher-order harmonics, revealing entrainment of the system’s nonlinear temporal dynamics. The phenomenon parallels injection locking in classical nonlinear systems, but emerges here in a strongly interacting quantum medium. This approach establishes a new method for stabilizing and controlling time-crystalline temporal order, with applications in precision sensing, quantum metrology, and timekeeping. Non-equilibrium Rydberg gases exhibit unique many-body phases arising from the interplay of coherent interactions and dissipation, yet controlling their temporal order remains challenging. This work demonstrates injection locking of a Rydberg dissipative time crystal using a radio-frequency electric field, achieving full synchronization and revealing dynamical behavior relevant to precision sensing and quantum metrology.
We present a subsystem-isolated study of aircraft-level vibration coupling to a hyperfine laser lock and its propagation to a two-photon Rydberg superheterodyne RF sensor. Here, the probe laser is stabilized to an atomic hyperfine transition, and RF electric fields are detected via a Rydberg-atom superheterodyne process that down-converts the signal to an optical readout. A compact Doppler-free saturated-absorption spectroscopy (SAS) module probing the 87 Rb 5 S 1/2 →5 P 3/2 hyperfine manifold was driven to NASA DC-8 in-flight vibration levels (<2kHz) to investigate the effects of vibration on the stabilization of a 780 nm laser. The stabilized 780 nm probe was combined with a 480 nm coupling laser to excite a room-temperature Rydberg sensor to the 63 D 5/2 state and driven for the RF superheterodyne detection via a ∼8.35GHz local oscillator coupling to the 64 P 3/2 state (RF 100 kHz detuned). Under nominal PID settings, vibration introduced low-frequency noise but did not cause the laser to unlock nor did it degrade the atomic RF readout. Probe wavemeter Allan deviations remain ⟨60kHzat τ ⟩20s at with and without vibration, indicating no loss of lock or MHz-scale drift. Independent frequency-noise-density measurements show no measurable difference between vibration and no-vibration conditions under nominal PID settings. The Rydberg spectrum showed <10% RF-amplitude deviation and a sensitivity of ∼1.5×10 −5 Vm −1 Hz −1/2 . Increasing integral gain by >10 3 transferred vibration noise to the servo, elevating low-frequency noise in the atomic RF spectrum, but with no measurable degradation of the RF sensing at 100 kHz detuning.
We demonstrate a method to simultaneously suppress the linewidths and stabilize the long-term frequency drifts of both 780-nm and 960-nm lasers to the 10-kHz level. We first use an iodine frequency stabilization laser as a frequency reference to stabilize the length of a tunable high-finesse transfer cavity (THFTC). Then two slave lasers of 780 nm and 960 nm are locked to this THFTC. In this way, the linewidths of slave lasers are suppressed to the order of 10 kHz, which are measured by delayed self-heterodyne measurements. Meanwhile, the long-term frequency drifts are stabilized to be less than 22 kHz for 10 h. With the locked lasers, we realize the coherent Rydberg excitation of a single Rb87 atom and keep the exciting stable and repeatable for 10 h, which is essential for Rydberg-mediated single-atom quantum information processing. This dual-laser frequency stabilization and transfer method can also be used in other high-resolution experiments in atomic physics, precision metrology, and molecular spectroscopy.