Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2602.10931

Probe-assisted Depopulation Pumping in Low-pressure Alkali-metal Vapor Cells for Magnetometry

M. E. Limes, J. Smoot, J. Perez, J. Freeman, C. Amano-Dolan, D. Peters, W. Lee

Published Feb 11, 2026• 0 citations
arXivHTMLPDF

Abstract

For precision atomic magnetometry, inert buffer gas is included in alkali-metal vapor cells to significantly broaden hyperfine transitions, which facilitates optical pumping and reduces diffusive relaxation, while also providing non-radiative excited state quenching. We show low-buffer gas pressure (below 50 Torr) alkali vapor cells with resolved hyperfine manifolds can also yield high-performance magnetometers. For high polarization in $^{87}$Rb, we optically pump $F=2$ states with narrow linewidth $σ_+$ light, while tuning a probe beam to depopulate $F=1$ states ($Δν= 6.8$ GHz from $F=2$). The probe tuning then also provides $F=2$ detection with high optical rotation and low probe broadening; we demonstrate top-bottom gradiometry, within a single 25 Torr, 0.5 cc cell, that yields an Earth's field free-precession magnetometer sensitivity of 18 fT/$\sqrt{\text{Hz}}$ with a 1 kHz bandwidth, as well as RF magnetometer sensitivity of 12 fT/$\sqrt{\text{Hz}}$ in a small band about 110 kHz.

DOI
10.48550/arxiv.2602.10931

Related papers

Influence of Buffer-Gas Pressure Inside Micro Alkali Vapor Cells on the Performance of Chip-Scale SERF Magnetometers

Lei Wu, Jintang Shang, Yu Ji +2 more

Spin-exchange-relaxation-free (SERF) optical atomic magnetometers are facing the challenges of dramatic decrease of sensitivity when the alkali vapor cells become small. This paper focuses on the sensitivity improvement of the chip-scale atomic magnetometer (CSAM) by changing buffer-gas pressures inside the microfabricated vapor cells. The rubidium vapor cells with three different buffer-gas pressures were tested in the SERF magnetometer. The influences of vapor cell temperature and pumping laser power on the device sensitivity are also characterized for further optimization. Results show that the three atomic vapor cells, with N2buffer-gas pressure of 0.20, 0.88, and 2.35 amg, have sensitivities of 900, 500, and 150 fT/Hz1/2, respectively. Results indicated that when the alkali vapor cells continue to be smaller, high buffer-gas pressure would provide an effective way to reduce the wall collision and improve the performance of CSAMs.

IEEE Transactions on Components Packaging and Manufacturing Technology•Dec 21, 2017•18 citations

Optical pumping of alkali-metal vapor in the quasi-high-pressure regime

Kezheng Yan, Jinbo Hu, Nan Zhao

Optical pumping is fundamental to high-precision measurement using thermal alkali-metal atoms in vapor cells. In applications such as atomic magnetometry, buffer gases (e.g., $\mathrm{N}_2$ or $\mathrm{He}$) at specific pressures are introduced to quench fluorescence and mitigate wall relaxation. In the high-pressure limit (e.g., the $\mathrm{N}_2$ pressure $p_{\mathrm{N}_2}> 1$~atm), where collisional broadening exceeds hyperfine splittings of the atoms, optical pumping theory provides a clear description of the angular momentum exchange between photons and atomic spins. However, in many magnetic sensing scenarios, the high-pressure approximation becomes inadequate as its pressure conditions are not strictly satisfied. Consequently, an explicit description of optical pumping under realistic pressures is critical for selecting operating points and enhancing system performance. To address this, we develop a unified theoretical framework of optical pumping in the quasi-high-pressure regime, where collisional broadening is comparable to the ground-state hyperfine splitting. We demonstrate that light absorption, spin polarization, and magnetic-resonance linewidth in this regime differ significantly from those predicted by the high-pressure limit and offer favorable operating conditions. Our study extends conventional modeling and offers critical guidance for atomic magnetometry operating under realistic buffer gas pressures.

physics.atom-phCross-listedarXiv:2603.05859•Physical Review A•Mar 9, 2026•0 citations

Optimizing longitudinal spin relaxation in miniaturized optically pumped magnetometers

A. McWilliam, S. Dyer, Dominic Hunter +7 more

The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micropill dispenser. We characterize the variation in the intrinsic longitudinal relaxation rate, γ 10 , and magnetic sensitivity, as a function of the resulting nitrogen buffer gas pressure. Measurements are conducted by employing an optically pumped magnetometer operating in a free-induction-decay configuration. γ 10 is extracted across a range of nitrogen pressures between 60 and 700 torr, measuring a minimum of 140 Hz at 115 torr. In addition, we achieve sensitivities as low as 130 fT / Hz at a bias field amplitude of about 50 μ T . With the optimal nitrogen buffer gas pressure now quantified and achievable post-fabrication, these mass-producible cells can be tailored to suit a variety of sensing applications, ensuring peak magnetometer performance. Published by the American Physical Society 2024

arXiv:2406.19178•Physical Review Applied•Dec 5, 2024•9 citations

Improving the sensitivity of optically pumped magnetometers by hyperfine repumping

V. Schultze, Theo Scholtes, R.P.J. IJsselsteijn +1 more

Most optically pumped magnetometers based on alkali atom vapor cells and pumped by a single narrow-band laser suffer from a loss of signal since atoms become trapped in the ground hyperfine states that are not coupled to the laser beam. This can be counteracted by additional optical repumping of these ground-state levels. We study hyperfine repumping using cesium vapor cells with partly overlapped ground-state splitting due to their nitrogen buffer-gas filling. We implement two methods of repumping and compare them to the conventional case of F=4 pumping: F=3 repumping with an additional repumper laser and combined pumping/repumping in the light-narrowing mode, where a single high-power laser is tuned near the F=3 transitions. All these modes are investigated for two different methods of spin-phase synchronization: the Mx and intensity modulation methods. For both methods, any kind of repumping results in a clear improvement of the magnetometer sensitivity compared to no repumping, but in the Mx mode it is more pronounced (about 50 versus 200 fT/√Hz for a 50 mm3 Cs vapor cell). The mechanisms responsible for the distinct results in the different working modes are discussed.

Journal of the Optical Society of America B•Apr 2, 2015•20 citations

Improvement of Sensitivity by Using Microfabricated Spherical Alkali Vapor Cells for Chip-Scale Atomic Magnetometers

Yu Ji, Jintang Shang, Qi Gan +2 more

The designs of microfabricated alkali vapor cells play an important role when the atomic magnetometers are developing toward on-chip integration. This paper presents microfabricated spherical alkali vapor cells with improved sensitivity for chip-scale atomic magnetometers. A microfabricated spherical rubidium vapor cell and a traditional microfabricated planar rubidium vapor cell are designed for comparison, which are of the same volume and interconnected by a microchannel to acquire equal inner buffer gas pressure. In chip-scale spin-exchange relaxation-free (SERF) atomic magnetometers, the rubidium polarization lifetimes of three pairs of spherical and planar vapor cells at different buffer gas pressures of 0.35, 0.73, and 2.00 amg are measured, respectively. The sensitivity of SERF atomic magnetometers using the vapor cells at a 0.35-amg buffer gas pressure is also measured. The results show that the transverse polarization lifetime of the spherical vapor cell is 2.46, 1.44, and 1.05 times that of the planar one at 0.35-, 0.73-, and 2.00-amg buffer gas pressures, respectively. Combining the improved polarization lifetime and increased optical path length, chip-scale SERF atomic magnetometer using the microspherical vapor cell has the sensitivity of 60 fT/Hz1/2from 5 to 15 Hz, while that based on the planar one is demonstrated with the sensitivity of 400 fT/Hz1/2from 5 to 15 Hz.

IEEE Transactions on Components Packaging and Manufacturing Technology•Sep 3, 2018•22 citations

Spin-exchange relaxation-free magnetometry using elliptically polarized light

Vishal Shah, Michael V. Romalis

Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of $7\text{ }\text{fT}/\sqrt{\text{Hz}}$ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.

arXiv:0903.2447•Physical Review A•Jul 24, 2009•273 citations
For precision atomic magnetometry, inert buffer gas is included in alkali-metal vapor cells to significantly broaden hyperfine transitions, which facilitates optical pumping and reduces diffusive relaxation, while also providing non-radiative excited state quenching. We show low-buffer gas pressure (below 50 Torr) alkali vapor cells with resolved hyperfine manifolds can also yield high-performance magnetometers. For high polarization in 87^{87}87Rb, we optically pump F=2F=2F=2 states with narrow linewidth σ+σ_+σ+​ light, while tuning a probe beam to depopulate F=1F=1F=1 states (Δν=6.8Δν= 6.8Δν=6.8 GHz from F=2F=2F=2). The probe tuning then also provides F=2F=2F=2 detection with high optical rotation and low probe broadening; we demonstrate top-bottom gradiometry, within a single 25 Torr, 0.5 cc cell, that yields an Earth's field free-precession magnetometer sensitivity of 18 fT/Hz\sqrt{\text{Hz}}Hz​ with a 1 kHz bandwidth, as well as RF magnetometer sensitivity of 12 fT/Hz\sqrt{\text{Hz}}Hz​ in a small band about 110 kHz.
Spin-exchange-relaxation-free (SERF) optical atomic magnetometers are facing the challenges of dramatic decrease of sensitivity when the alkali vapor cells become small. This paper focuses on the sensitivity improvement of the chip-scale atomic magnetometer (CSAM) by changing buffer-gas pressures inside the microfabricated vapor cells. The rubidium vapor cells with three different buffer-gas pressures were tested in the SERF magnetometer. The influences of vapor cell temperature and pumping laser power on the device sensitivity are also characterized for further optimization. Results show that the three atomic vapor cells, with N2buffer-gas pressure of 0.20, 0.88, and 2.35 amg, have sensitivities of 900, 500, and 150 fT/Hz1/2, respectively. Results indicated that when the alkali vapor cells continue to be smaller, high buffer-gas pressure would provide an effective way to reduce the wall collision and improve the performance of CSAMs.
Optical pumping is fundamental to high-precision measurement using thermal alkali-metal atoms in vapor cells. In applications such as atomic magnetometry, buffer gases (e.g., N2\mathrm{N}_2N2​ or He\mathrm{He}He) at specific pressures are introduced to quench fluorescence and mitigate wall relaxation. In the high-pressure limit (e.g., the N2\mathrm{N}_2N2​ pressure pN2>1p_{\mathrm{N}_2}> 1pN2​​>1~atm), where collisional broadening exceeds hyperfine splittings of the atoms, optical pumping theory provides a clear description of the angular momentum exchange between photons and atomic spins. However, in many magnetic sensing scenarios, the high-pressure approximation becomes inadequate as its pressure conditions are not strictly satisfied. Consequently, an explicit description of optical pumping under realistic pressures is critical for selecting operating points and enhancing system performance. To address this, we develop a unified theoretical framework of optical pumping in the quasi-high-pressure regime, where collisional broadening is comparable to the ground-state hyperfine splitting. We demonstrate that light absorption, spin polarization, and magnetic-resonance linewidth in this regime differ significantly from those predicted by the high-pressure limit and offer favorable operating conditions. Our study extends conventional modeling and offers critical guidance for atomic magnetometry operating under realistic buffer gas pressures.
The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micropill dispenser. We characterize the variation in the intrinsic longitudinal relaxation rate, γ 10 , and magnetic sensitivity, as a function of the resulting nitrogen buffer gas pressure. Measurements are conducted by employing an optically pumped magnetometer operating in a free-induction-decay configuration. γ 10 is extracted across a range of nitrogen pressures between 60 and 700 torr, measuring a minimum of 140 Hz at 115 torr. In addition, we achieve sensitivities as low as 130 fT / Hz at a bias field amplitude of about 50 μ T . With the optimal nitrogen buffer gas pressure now quantified and achievable post-fabrication, these mass-producible cells can be tailored to suit a variety of sensing applications, ensuring peak magnetometer performance. Published by the American Physical Society 2024
Most optically pumped magnetometers based on alkali atom vapor cells and pumped by a single narrow-band laser suffer from a loss of signal since atoms become trapped in the ground hyperfine states that are not coupled to the laser beam. This can be counteracted by additional optical repumping of these ground-state levels. We study hyperfine repumping using cesium vapor cells with partly overlapped ground-state splitting due to their nitrogen buffer-gas filling. We implement two methods of repumping and compare them to the conventional case of F=4 pumping: F=3 repumping with an additional repumper laser and combined pumping/repumping in the light-narrowing mode, where a single high-power laser is tuned near the F=3 transitions. All these modes are investigated for two different methods of spin-phase synchronization: the Mx and intensity modulation methods. For both methods, any kind of repumping results in a clear improvement of the magnetometer sensitivity compared to no repumping, but in the Mx mode it is more pronounced (about 50 versus 200 fT/√Hz for a 50 mm3 Cs vapor cell). The mechanisms responsible for the distinct results in the different working modes are discussed.
The designs of microfabricated alkali vapor cells play an important role when the atomic magnetometers are developing toward on-chip integration. This paper presents microfabricated spherical alkali vapor cells with improved sensitivity for chip-scale atomic magnetometers. A microfabricated spherical rubidium vapor cell and a traditional microfabricated planar rubidium vapor cell are designed for comparison, which are of the same volume and interconnected by a microchannel to acquire equal inner buffer gas pressure. In chip-scale spin-exchange relaxation-free (SERF) atomic magnetometers, the rubidium polarization lifetimes of three pairs of spherical and planar vapor cells at different buffer gas pressures of 0.35, 0.73, and 2.00 amg are measured, respectively. The sensitivity of SERF atomic magnetometers using the vapor cells at a 0.35-amg buffer gas pressure is also measured. The results show that the transverse polarization lifetime of the spherical vapor cell is 2.46, 1.44, and 1.05 times that of the planar one at 0.35-, 0.73-, and 2.00-amg buffer gas pressures, respectively. Combining the improved polarization lifetime and increased optical path length, chip-scale SERF atomic magnetometer using the microspherical vapor cell has the sensitivity of 60 fT/Hz1/2from 5 to 15 Hz, while that based on the planar one is demonstrated with the sensitivity of 400 fT/Hz1/2from 5 to 15 Hz.
Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of 7 fT/Hz7\text{ }\text{fT}/\sqrt{\text{Hz}}7 fT/Hz​ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.