Broadband Heterodyne Microwave Detection using Rydberg Atoms with High Sensitivity

Hsuan-Jui Su, Shao-Cheng Fang, Ting-An Li, Chen-Hao Chang, Yu-Chi Chen, Yi-Hsin Chen

physics.atom-phquant-phSubmitted Jan 27, 2026• Announced Jan 28, 2026• 0 citations
arXivHTMLPDF

Abstract

We present a Rydberg atom-based microwave electric field sensor that achieves extended dynamic range and enhanced sensitivity across a broad bandwidth. By characterizing the Autler-Townes (AT) splitting induced by a single-tone microwave field, we demonstrate a spectroscopic method that simultaneously extracts both the microwave frequency and electric field strength directly from the splitting pattern. We implement dual-tone heterodyne detection, achieving a minimum detectable field strength on the order of uV/cm and a sensitivity in the sub-uV/cm/Hz^1/2 regime, while extending the operational bandwidth up to 3 GHz. Through systematic characterization of frequency and power dependencies, we identify optimal operating conditions to minimize power broadening in the resonant AT regime and maximize sensitivity in the far-off-resonance AC Stark regime. The resulting platform combines high sensitivity, broad bandwidth, and a dynamic range of approximately 90 dB, establishing Rydberg atoms as practical sensors for precision electric field metrology.

Comments
8 pages, 5 figures

Related papers

Broadband Rydberg Atomic Microwave Sensing with 44.6$\,$MHz Instantaneous Bandwidth

Yuhan Yan, Xuejie Li, Jinyin 金银 Wan 万 +6 more

Rydberg atoms have become a promising novel type of microwave sensor due to their excellent physical properties -- broad frequency coverage and large electric dipole moments. High sensitivity and broad instantaneous bandwidth are two indispensable requirements for deployable Rydberg microwave sensors. However, enabling broadband operation while retaining high sensitivity has been a longstanding barrier limiting their applications. We propose and experimentally demonstrate a Rydberg microwave sensor whose instantaneous bandwidth is significantly enhanced via an auxiliary microwave field. By finely modulating the Rydberg energy levels with this field, we broaden the bandwidth substantially while retaining the sensor's inherent high sensitivity. An instantaneous bandwidth of 44.6$\,$MHz ($\pm$22.3$\,$MHz) with a sensitivity of 225.7$\,$nV$\,$cm$^{-1}\,$Hz$^{-1/2}$ is realized in a thermal \(^{87}\)Rb vapor with the local microwave frequency of 16.03$\,$GHz. Our work delivers concurrent broad instantaneous bandwidth and high sensitivity for Rydberg microwave sensors, paving a technically viable path for their practical deployment in broadband microwave metrology, radar, and wireless communication.

arXiv:2606.25555•Jun 24, 2026•0 citations

Continuous broadband microwave electric field measurement in Rydberg atoms based on the DC Stark effect

Kang Ouyang, Yuansheng Shi, Mingwei Lei +1 more

We demonstrate a method for broadband tunable continuous frequency electric field measurement based on the DC Stark effect in Rydberg atoms. In our experiment, we place a pair of parallel electrode plates inside the atomic vapor cell, utilizing the DC Stark effect to induce splitting and shifting of the Rydberg energy levels, thereby altering the resonance frequency of the Stark subpeaks. By employing the 52D5/2 Rydberg state, we achieve electric field measurements in the frequency range of 5.083–14.470 GHz. At an EDC of 3.45 V/cm and a resonant microwave frequency of 14.470 GHz, using heterodyne technology, the microwave electric field sensitivity is 538.89 μV/cm/√Hz, with a linear dynamic range of 23 dB. In comparison, a Rydberg heterodyne receiver with an EDC of 0 V/cm and a resonant microwave frequency of 5.083 GHz has a sensitivity of 5.43 μV/cm/√Hz and a linear dynamic range of 51 dB. This work will promote the study of atomic microwave receivers in continuous microwave frequency measurement.

Applied Physics Letters•Dec 25, 2023•27 citations

Broadband Rydberg atom-based radio-frequency field sensor

Jiao Yue-Chun, Jianming Zhao, Jia Suo-Tang

Significant progress has been made in atom-based measurements of length, time, gravity and electromagnetic fields in recently years. Rydberg atom-based microwave electric field measurement, using electromagnetically induced transparency (EIT) in room temperature alkali-metal vapors, has been extensively investigated and aroused the broad interest. This approach may establish a new standard for the measurements of microwave (MW) and radio frequency (RF) electric fields.In this review, we describe the work on a new method of measuring electric fields based on quantum interference by using either cesium or rubidium atoms contained in a dielectric vapor cell. Rydberg atoms with principal quantum number n >>1 have large direct current (DC) polarizabilities and microwave transition dipole moments, thereby making them extremely sensitive to external electric fields. Using the Rydberg three-level EIT to detect the level splitting and shift that is induced by the external field, we can realize a rapid and robust self-calibration method of measuring the electric field in a frequency range from 0.01 GHz to 1000 GHz. For the MW electric field (frequency range > 1 GHz), the MW field causes the Rydberg states to split, known as an Autler-Townes splitting (A-T) effect when the applied microwave can resonate with adjacent Rydberg states. The MW coupled A-T splitting is proportional to the applied electric field strength, from which the field strength is measured. Using the EIT window, a high sensitivity of 3 μV·cm-1·Hz-1/2 and small electric field of 1 μV/cm are expected to be achieved with a modest setup, and the limitations of the sensitivity are also addressed in the review. For the RF field at frequency mj EIT lines, and avoided crossings formed with the fine-structure levels of equal mj and different J's, which is used to calibrate and measure the RF field amplitude. On the other hand, the dependence of the EIT-line strength on the RF field polarization provides a fast and robust polarization measurement of RF fields based on matching experimental data with a theoretical simulation. The measurements of minimum strengths and sensitivity of RF fields based on Rydberg atoms are one order magnitude below the values obtained by traditional antenna methods. The atom-based field measurement paves the way for determining fields through calibration-free, invariable atomic properties and miniaturization. We also propose its various potential applications in the future.

Acta Physica Sinica•Jan 1, 2018•7 citations

Continuously tunable radio frequency electrometry with Rydberg atoms

Jinlian Hu, Huaqiang Li, Rong Song +4 more

We demonstrate a continuously tunable electric field measurement based on the far off-resonant AC stark effect in a Rydberg atomic vapor cell. In this configuration, a strong far off-resonant field, denoted as a local oscillator (LO) field, acts as a gain to shift the Rydberg level to a high sensitivity region. An incident weak signal field with a few hundreds of kHz difference from the LO field is mixed with the LO field in the Rydberg system to generate an intermediate frequency signal, which is read out by Rydberg electromagnetically induced transparency (Rydberg-EIT) spectroscopy. Not like resonant EIT-Autler–Townes spectra, we realize the electric field measurement of the signal frequency from 2 to 5 GHz using a single Rydberg state. The detectable field strength is down to 2.25 μV/cm with sensitivity of the electrometry 712 nV cm−1 Hz−1/2, and a linear dynamic range is over 65 dB. The detectable field strength is comparable with a resonant microwave-dressed Rydberg heterodyne receiver using the same system, which is 0.96 μV/cm with sensitivity of 304 nV cm–1 Hz−1/2. We also show the system has an inherent polarization selectivity feature. Our method can provide high sensitivity of electric field measurement and be extended to arbitrary frequency measurements.

arXiv:2201.10068•Applied Physics Letters•Jul 4, 2022•97 citations

Extending bandwidth sensitivity of Rydberg-atom-based microwave electrometry using an auxiliary microwave field

Yue Cui, Feng-Dong Jia, Jianhai Hao +13 more

We demonstrate the use of an auxiliary microwave field to extend the bandwidth sensitivity of Rydberg-atom-based microwave electrometry. Electromagnetically induced transparency (EIT) and Autler-Townes (AT) splitting in Rydberg atom microwave electrometry provide advantageous sensitivity for the resonant detection of microwave (MW) fields because the Stark shift of the target Rydberg state takes the linear form of AT splitting. However, the sensitivity is reduced by several orders of magnitude for detuned MW fields because the Stark shift of the target Rydberg state depends on a weak nonlinear effect. We show that the auxiliary microwave field with appropriate Rabi frequency or detuning could shift the atomic energy levels to bring a particular Rydberg-Rydberg transition of interest for microwave sensing into resonance with the target microwave field. Using the atomic superheterodyne method, we verified the general method that regulates Rydberg energy levels using an auxiliary microwave field. The experimental results of this study confirm that this technique works efficiently for detecting microwave fields detuned by up to 100 MHz from resonance with the field-free Rydberg-Rydberg transition used for sensing. The measurement sensitivity of the detuned target field is increased by a factor of 10 compared with that achieved without the application of the auxiliary dressing field.

Physical Review A•Apr 3, 2023•47 citations

A read-out enhancement for microwave electric field sensing with Rydberg atoms

Harald Kübler, James P. Shaffer

We have shown that Rydberg atoms can be used for high-sensitivity, absolute sensing of radio frequency (RF) electric fields. We achieved a sensitivity of 3 μVcm-1Hz-1/2 for two read-out strategies. Results using a Mach-Zehnder interferometer2 and frequency modulated spectroscopy both achieve similar photon shot noise limited sensitivity. Fundamental limits to the sensitivity of the Rydberg atom-based RF electric field sensing have been addressed. Depending on the spectral resolution of the read-out, either the RF induced transmission line frequency splitting, the Autler-Townes regime, or a change in the on-resonant absorption, the amplitude regime, can be used to determine the RF electric field. Here, we present theoretical results of a 3-photon read-out scheme which enables the Autler-Townes regime of Rydberg atom-based RF electrometry to be extended to lower RF electric field strengths. We show that the residual Doppler shifts can, in principle, be reduced to ~11.8 kHz, on the order of the Rydberg atom natural lindewidths, using the approach.

SPIE Quantum Technologies•May 21, 2018•33 citations
We present a Rydberg atom-based microwave electric field sensor that achieves extended dynamic range and enhanced sensitivity across a broad bandwidth. By characterizing the Autler-Townes (AT) splitting induced by a single-tone microwave field, we demonstrate a spectroscopic method that simultaneously extracts both the microwave frequency and electric field strength directly from the splitting pattern. We implement dual-tone heterodyne detection, achieving a minimum detectable field strength on the order of uV/cm and a sensitivity in the sub-uV/cm/Hz^1/2 regime, while extending the operational bandwidth up to 3 GHz. Through systematic characterization of frequency and power dependencies, we identify optimal operating conditions to minimize power broadening in the resonant AT regime and maximize sensitivity in the far-off-resonance AC Stark regime. The resulting platform combines high sensitivity, broad bandwidth, and a dynamic range of approximately 90 dB, establishing Rydberg atoms as practical sensors for precision electric field metrology.
Broadband Rydberg Atomic Microwave Sensing with 44.6 \,MHz Instantaneous Bandwidth
Rydberg atoms have become a promising novel type of microwave sensor due to their excellent physical properties -- broad frequency coverage and large electric dipole moments. High sensitivity and broad instantaneous bandwidth are two indispensable requirements for deployable Rydberg microwave sensors. However, enabling broadband operation while retaining high sensitivity has been a longstanding barrier limiting their applications. We propose and experimentally demonstrate a Rydberg microwave sensor whose instantaneous bandwidth is significantly enhanced via an auxiliary microwave field. By finely modulating the Rydberg energy levels with this field, we broaden the bandwidth substantially while retaining the sensor's inherent high sensitivity. An instantaneous bandwidth of 44.6 \,MHz ($\pm22.322.322.3\,MHz)withasensitivityof225.7MHz) with a sensitivity of 225.7MHz)withasensitivityof225.7\,nVnVnV\,cmcmcm^{-1}\,HzHzHz^{-1/2}$ is realized in a thermal 87^{87}87Rb vapor with the local microwave frequency of 16.03 \,GHz. Our work delivers concurrent broad instantaneous bandwidth and high sensitivity for Rydberg microwave sensors, paving a technically viable path for their practical deployment in broadband microwave metrology, radar, and wireless communication.
We demonstrate a method for broadband tunable continuous frequency electric field measurement based on the DC Stark effect in Rydberg atoms. In our experiment, we place a pair of parallel electrode plates inside the atomic vapor cell, utilizing the DC Stark effect to induce splitting and shifting of the Rydberg energy levels, thereby altering the resonance frequency of the Stark subpeaks. By employing the 52D5/2 Rydberg state, we achieve electric field measurements in the frequency range of 5.083–14.470 GHz. At an EDC of 3.45 V/cm and a resonant microwave frequency of 14.470 GHz, using heterodyne technology, the microwave electric field sensitivity is 538.89 μV/cm/√Hz, with a linear dynamic range of 23 dB. In comparison, a Rydberg heterodyne receiver with an EDC of 0 V/cm and a resonant microwave frequency of 5.083 GHz has a sensitivity of 5.43 μV/cm/√Hz and a linear dynamic range of 51 dB. This work will promote the study of atomic microwave receivers in continuous microwave frequency measurement.
Significant progress has been made in atom-based measurements of length, time, gravity and electromagnetic fields in recently years. Rydberg atom-based microwave electric field measurement, using electromagnetically induced transparency (EIT) in room temperature alkali-metal vapors, has been extensively investigated and aroused the broad interest. This approach may establish a new standard for the measurements of microwave (MW) and radio frequency (RF) electric fields.In this review, we describe the work on a new method of measuring electric fields based on quantum interference by using either cesium or rubidium atoms contained in a dielectric vapor cell. Rydberg atoms with principal quantum number n >>1 have large direct current (DC) polarizabilities and microwave transition dipole moments, thereby making them extremely sensitive to external electric fields. Using the Rydberg three-level EIT to detect the level splitting and shift that is induced by the external field, we can realize a rapid and robust self-calibration method of measuring the electric field in a frequency range from 0.01 GHz to 1000 GHz. For the MW electric field (frequency range > 1 GHz), the MW field causes the Rydberg states to split, known as an Autler-Townes splitting (A-T) effect when the applied microwave can resonate with adjacent Rydberg states. The MW coupled A-T splitting is proportional to the applied electric field strength, from which the field strength is measured. Using the EIT window, a high sensitivity of 3 μV·cm-1·Hz-1/2 and small electric field of 1 μV/cm are expected to be achieved with a modest setup, and the limitations of the sensitivity are also addressed in the review. For the RF field at frequency mj EIT lines, and avoided crossings formed with the fine-structure levels of equal mj and different J's, which is used to calibrate and measure the RF field amplitude. On the other hand, the dependence of the EIT-line strength on the RF field polarization provides a fast and robust polarization measurement of RF fields based on matching experimental data with a theoretical simulation. The measurements of minimum strengths and sensitivity of RF fields based on Rydberg atoms are one order magnitude below the values obtained by traditional antenna methods. The atom-based field measurement paves the way for determining fields through calibration-free, invariable atomic properties and miniaturization. We also propose its various potential applications in the future.
We demonstrate a continuously tunable electric field measurement based on the far off-resonant AC stark effect in a Rydberg atomic vapor cell. In this configuration, a strong far off-resonant field, denoted as a local oscillator (LO) field, acts as a gain to shift the Rydberg level to a high sensitivity region. An incident weak signal field with a few hundreds of kHz difference from the LO field is mixed with the LO field in the Rydberg system to generate an intermediate frequency signal, which is read out by Rydberg electromagnetically induced transparency (Rydberg-EIT) spectroscopy. Not like resonant EIT-Autler–Townes spectra, we realize the electric field measurement of the signal frequency from 2 to 5 GHz using a single Rydberg state. The detectable field strength is down to 2.25 μV/cm with sensitivity of the electrometry 712 nV cm−1 Hz−1/2, and a linear dynamic range is over 65 dB. The detectable field strength is comparable with a resonant microwave-dressed Rydberg heterodyne receiver using the same system, which is 0.96 μV/cm with sensitivity of 304 nV cm–1 Hz−1/2. We also show the system has an inherent polarization selectivity feature. Our method can provide high sensitivity of electric field measurement and be extended to arbitrary frequency measurements.
We demonstrate the use of an auxiliary microwave field to extend the bandwidth sensitivity of Rydberg-atom-based microwave electrometry. Electromagnetically induced transparency (EIT) and Autler-Townes (AT) splitting in Rydberg atom microwave electrometry provide advantageous sensitivity for the resonant detection of microwave (MW) fields because the Stark shift of the target Rydberg state takes the linear form of AT splitting. However, the sensitivity is reduced by several orders of magnitude for detuned MW fields because the Stark shift of the target Rydberg state depends on a weak nonlinear effect. We show that the auxiliary microwave field with appropriate Rabi frequency or detuning could shift the atomic energy levels to bring a particular Rydberg-Rydberg transition of interest for microwave sensing into resonance with the target microwave field. Using the atomic superheterodyne method, we verified the general method that regulates Rydberg energy levels using an auxiliary microwave field. The experimental results of this study confirm that this technique works efficiently for detecting microwave fields detuned by up to 100 MHz from resonance with the field-free Rydberg-Rydberg transition used for sensing. The measurement sensitivity of the detuned target field is increased by a factor of 10 compared with that achieved without the application of the auxiliary dressing field.
We have shown that Rydberg atoms can be used for high-sensitivity, absolute sensing of radio frequency (RF) electric fields. We achieved a sensitivity of 3 μVcm-1Hz-1/2 for two read-out strategies. Results using a Mach-Zehnder interferometer2 and frequency modulated spectroscopy both achieve similar photon shot noise limited sensitivity. Fundamental limits to the sensitivity of the Rydberg atom-based RF electric field sensing have been addressed. Depending on the spectral resolution of the read-out, either the RF induced transmission line frequency splitting, the Autler-Townes regime, or a change in the on-resonant absorption, the amplitude regime, can be used to determine the RF electric field. Here, we present theoretical results of a 3-photon read-out scheme which enables the Autler-Townes regime of Rydberg atom-based RF electrometry to be extended to lower RF electric field strengths. We show that the residual Doppler shifts can, in principle, be reduced to ~11.8 kHz, on the order of the Rydberg atom natural lindewidths, using the approach.