arXiv:2507.10386 · Journal of Applied Physics

Optimization and characterization of laser excitation for quantum sensing with single nitrogen-vacancy centers

Alejandro Martínez-Méndez, Jesús Moreno-Meseguer, Mariusz Mrózek, Adam M. Wojciechowski, Raúl González Brouwer, Priya Balasubramanian, Fedor Jelezko, Javier Prior

Published Feb 5, 2026• 2 citations
arXivHTMLPDF

Abstract

In this work, we present a comprehensive method of characterization and optimization of laser irradiation within a confocal microscope tailored to quantum sensing experiments using nitrogen-vacancy (NV) centers. While confocal microscopy is well-suited for such experiments, precise control and understanding of several optical parameters are essential for reliable single-emitter studies. We investigate the laser beam intensity profile, single-photon emission statistics, fluorescence response under varying polarization and saturation conditions, spectral characteristics, and the temporal profiles of readout and reinitialization pulses. The beam quality is assessed using the beam propagation factor M2, determined via the razorblade technique. An optical fluorescence spectrum is recorded to confirm NV center emission. To confirm single-emitter operation, we measure second-order autocorrelation function g(2)(τ). Saturation behavior is analyzed by varying laser power and recording the corresponding fluorescence, while polarization dependence is studied using a half-wave (λ/2) plate. A temporal laser pulse profile is examined by modulating the power of an acousto-optic modulator. After optimizing all relevant parameters, we demonstrate the microscope’s capabilities in driving spin transitions of a single NV center. This work establishes a straightforward and effective protocol for laser excitation optimization, enhancing the performance and reliability of NV-based quantum sensors.

DOI
10.1063/5.0293773

Related papers

Setup of a Confocal Fluorescence Microscope for the Detection and Characterization of Single NV Centers in Diamond

Manuel Riedmann, Lucas Kirchbach, Andreas Stute

Single nitrogen vacancy (NV) centers in diamond serve as a photonic platform for quantum sensing and computing applications. They can be created deterministically using femtosecond laser pulses. Such writing process requires high-resolution fluorescence detection with a high signal-to-noise ratio, which is accomplished by setting up a homebuilt confocal fluorescence microscope. The microscope shall monitor the fluorescence of newly formed NV centers during the writing process. In addition, it will be used to characterize the NV centers’ spin coherence times, orientation in the diamond lattice and single-emitter characteristics via the intensity correlation function g(2)(tau). In the future, this setup is also planned to be employed for STED-microscopy of twin NV centers.

•Feb 5, 2026•0 citations

Photoluminescence characterization of NV centers in CVD diamond as a function of different nitrogen doping levels for quantum sensing applications

Sierra Gómez, Javier, Silva Neto, José Vieira da, Trava Airoldi, Vladimir Jesus +1 more

Nitrogen-vacancy (NV) centers in single-crystal CVD diamond are promising candidates for quantum sensing due to their remarkable optical and spin properties [1]. These defects exhibit stable photoluminescence (PL), long spin coherence times, and high sensitivity to external fields [2]. In this study, we present a room-temperature PL characterization of NV centers excited with a 532 nm laser. The setup was optimized for high signal-to-noise ratio and spectral resolution. Key parameters analyzed include emission intensity, zero-phonon line (ZPL) at ~637 nm, phonon sidebands, and the charge state distribution between NV⁰ and NV⁻. The NV⁻ state, crucial for spin-based sensing, is evaluated to understand its stability under different nitrogen doping conditions [3]. The relative intensities of NV⁰ and NV⁻ provide insights into nitrogen incorporation and vacancy formation. These results contribute to optimizing synthesis conditions for enhanced NV⁻ concentration, supporting the advancement of diamond-based quantum sensing technologies.

•Jan 1, 2025•0 citations

Magnetometry based on the excited-state lifetimes of a single nitrogen-vacancy center in diamond

Felix M. Stürner, Yan Liu, Pierre-Olivier Colard +2 more

So far most well-established quantum sensing techniques based on the negatively charged nitrogen-vacancy (NV) center in diamond utilize the recorded fluorescence intensity to detect the electronic spin states. However, the fluorescence intensity of a NV center is not only dependent on its spin state, but also affected by measurement issues, such as fluctuations of the excitation laser power and charge state transformation of the NV center. Instabilities in terms of output power or polarization changes in the laser source as well as sample drifts during a measurement are common factors that weaken the precision. Here, we demonstrate proof-of-principle of a sensing method making use of the excited-state lifetimes of a NV center for magnetometry experiments.

Applied Physics Letters•Sep 27, 2021•27 citations

Temporal filtered quantum sensing with the nitrogen-vacancy center in diamond

Florian Boehm, Yan Liu, Chengliang Yue +5 more

Nitrogen vacancy centers in diamond are among the leading solid state quantum platforms, offering exceptional spatial resolution and sensitivity for applications such as magnetic field sensing, thermometry, and bioimaging. However, in high background environments,such as those encountered in in vitro diagnostics, the performance of NV based sensors can be compromised by strong background fluorescence, particularly from substrates such as nitrocellulose. In this work, we analytically and experimentally investigate the use of pulsed laser excitation combined with time gating techniques to suppress background fluorescence and enhance the signal to noise ratio in NV based quantum sensing, with an emphasis on spin enhanced biosensing. Through experimental studies using mixed ensembles of silicon vacancy and NV centers in bulk diamond, as well as fluorescent nanodiamonds on NC substrates, we demonstrate significant improvements in NV spin resonance visibility, demonstrated by an increase of the SNR by up to 4x, and a resulting measurement time reduction by 16x. The presented technique and results here can help significantly increase the readout efficiency and speed in future applications of NV centers in high background environments, such as in IVD, where the NV centers are used as a fluorescent label for biomolecules.

quant-pharXiv:2511.02369•Nov 5, 2025

Purcell and Pulse Induced Impact for Measurement Based on Nitrogen-Vacancy Centers in Diamond

Lu Min Ji, Li Ye Zhao, Yu Hai Wang

Nitrogen-vacancy (NV) color centers in diamond serve as promising atomic spin systems for measurement applications requiring high accuracy and sensitivity. A key challenge in NV-based quantum sensing is minimizing spin readout noise to approach the standard quantum limit (SQL). Based on a six-level model, this work analyze the dependence of NV-based quantum sensing performance, including spin state readout noise and signal-to-noise ratio (SNR), on controllable parameters such as the Purcell factor and excitation laser pulse characteristics. This study demonstrates that a shorter excitation pulse duration results in a higher saturation value of ground-state spin polarization, while the total time required for the polarization process remains constant. Additionally, the spin readout noise does not improve monotonically with decreasing excitation pulse duration; instead, it initially decreases and subsequently increases as the pulse duration varies. The spin readout noise reaches its optimal level when the pulse duration is 3 ns. Furthermore, no positive correlation exists between the signal-to-noise ratio (SNR) and the Purcell factor, and there is also an optimal value for SNR. When the pulse duration ranges from 1 ns to 40 ns, the variation in SNR is relatively insignificant. This research offers a novel perspective for enhancing the performance of quantum sensing based on diamond defects, such as nitrogen-vacancy (NV) centers.

Key engineering materials•Nov 25, 2025•0 citations

Charge state dynamics during excitation and depletion of the nitrogen vacancy center in Diamond

Luke Hacquebard

The nitrogen-vacancy (NV) defect center in diamond shows great promise for many applications in quantum information processing and precision sensing. The NV center naturally occurs in two different charge states (NV0 and NV-), which have very different optical and spin properties. Understanding laser-induced switching between these charge states is essential for taking advantage of the NV center's properties in many contexts. Reducing the amount of optically-induced ionization is often important for increasing SNR and spin-coherence times. On the other hand charge state switching can be taken advantage of through spin-to-charge conversion techniques, enhancing optical spin-state readout of the NV center [1].A method for charge state initialization and readout using yellow (594 nm) laser illumination was used to investigate the ionization and recombination processes from other laser sources. The commonly used CW green (532 nm) laser was found to follow a simple two-level process at low powers while deviation occurred at higher powers, resulting in an unexpected peak in NV- population. This unexpected behaviour was found to be associated with an unknown process relaxing in the dark with a lifetime of 8.8 ± 0.6 µs. A spin-dependence in ionization was also observed due to the reduced ionization rate out of the metastable singlet state in NV- at this wavelength.Pulsed green (531 nm) and red (766 nm) illumination were used to study the charge state dynamics during excitation and depletion processes. Red illumination is known to cause depletion of NV- fluorescence, but it was initially unclear how much of this reduction is due to stimulated emission and how much is from charge state ionization, as both are non-radiative processes. By simultaneously modeling the measured excitation, fluorescence depletion, and charge state switching of the pulsed lasers, we were able to quantitatively extract the relative rates of excitation, ionization, and stimulated emission for the two colors of pulsed laser. The models developed through these measurements were used to calculate the amount of expected spin-polarization after a single excitation then depletion pulse sequence. These results have implications for stimulated emission depletion (STED) microscopy [2], laser threshold magnetometry [3] and spin to charge conversion [1,4].

•Jan 1, 2018•0 citations
In this work, we present a comprehensive method of characterization and optimization of laser irradiation within a confocal microscope tailored to quantum sensing experiments using nitrogen-vacancy (NV) centers. While confocal microscopy is well-suited for such experiments, precise control and understanding of several optical parameters are essential for reliable single-emitter studies. We investigate the laser beam intensity profile, single-photon emission statistics, fluorescence response under varying polarization and saturation conditions, spectral characteristics, and the temporal profiles of readout and reinitialization pulses. The beam quality is assessed using the beam propagation factor M2, determined via the razorblade technique. An optical fluorescence spectrum is recorded to confirm NV center emission. To confirm single-emitter operation, we measure second-order autocorrelation function g(2)(τ). Saturation behavior is analyzed by varying laser power and recording the corresponding fluorescence, while polarization dependence is studied using a half-wave (λ/2) plate. A temporal laser pulse profile is examined by modulating the power of an acousto-optic modulator. After optimizing all relevant parameters, we demonstrate the microscope’s capabilities in driving spin transitions of a single NV center. This work establishes a straightforward and effective protocol for laser excitation optimization, enhancing the performance and reliability of NV-based quantum sensors.
Single nitrogen vacancy (NV) centers in diamond serve as a photonic platform for quantum sensing and computing applications. They can be created deterministically using femtosecond laser pulses. Such writing process requires high-resolution fluorescence detection with a high signal-to-noise ratio, which is accomplished by setting up a homebuilt confocal fluorescence microscope. The microscope shall monitor the fluorescence of newly formed NV centers during the writing process. In addition, it will be used to characterize the NV centers’ spin coherence times, orientation in the diamond lattice and single-emitter characteristics via the intensity correlation function g(2)(tau). In the future, this setup is also planned to be employed for STED-microscopy of twin NV centers.
Nitrogen-vacancy (NV) centers in single-crystal CVD diamond are promising candidates for quantum sensing due to their remarkable optical and spin properties [1]. These defects exhibit stable photoluminescence (PL), long spin coherence times, and high sensitivity to external fields [2]. In this study, we present a room-temperature PL characterization of NV centers excited with a 532 nm laser. The setup was optimized for high signal-to-noise ratio and spectral resolution. Key parameters analyzed include emission intensity, zero-phonon line (ZPL) at ~637 nm, phonon sidebands, and the charge state distribution between NV⁰ and NV⁻. The NV⁻ state, crucial for spin-based sensing, is evaluated to understand its stability under different nitrogen doping conditions [3]. The relative intensities of NV⁰ and NV⁻ provide insights into nitrogen incorporation and vacancy formation. These results contribute to optimizing synthesis conditions for enhanced NV⁻ concentration, supporting the advancement of diamond-based quantum sensing technologies.
So far most well-established quantum sensing techniques based on the negatively charged nitrogen-vacancy (NV) center in diamond utilize the recorded fluorescence intensity to detect the electronic spin states. However, the fluorescence intensity of a NV center is not only dependent on its spin state, but also affected by measurement issues, such as fluctuations of the excitation laser power and charge state transformation of the NV center. Instabilities in terms of output power or polarization changes in the laser source as well as sample drifts during a measurement are common factors that weaken the precision. Here, we demonstrate proof-of-principle of a sensing method making use of the excited-state lifetimes of a NV center for magnetometry experiments.
Nitrogen vacancy centers in diamond are among the leading solid state quantum platforms, offering exceptional spatial resolution and sensitivity for applications such as magnetic field sensing, thermometry, and bioimaging. However, in high background environments,such as those encountered in in vitro diagnostics, the performance of NV based sensors can be compromised by strong background fluorescence, particularly from substrates such as nitrocellulose. In this work, we analytically and experimentally investigate the use of pulsed laser excitation combined with time gating techniques to suppress background fluorescence and enhance the signal to noise ratio in NV based quantum sensing, with an emphasis on spin enhanced biosensing. Through experimental studies using mixed ensembles of silicon vacancy and NV centers in bulk diamond, as well as fluorescent nanodiamonds on NC substrates, we demonstrate significant improvements in NV spin resonance visibility, demonstrated by an increase of the SNR by up to 4x, and a resulting measurement time reduction by 16x. The presented technique and results here can help significantly increase the readout efficiency and speed in future applications of NV centers in high background environments, such as in IVD, where the NV centers are used as a fluorescent label for biomolecules.
Nitrogen-vacancy (NV) color centers in diamond serve as promising atomic spin systems for measurement applications requiring high accuracy and sensitivity. A key challenge in NV-based quantum sensing is minimizing spin readout noise to approach the standard quantum limit (SQL). Based on a six-level model, this work analyze the dependence of NV-based quantum sensing performance, including spin state readout noise and signal-to-noise ratio (SNR), on controllable parameters such as the Purcell factor and excitation laser pulse characteristics. This study demonstrates that a shorter excitation pulse duration results in a higher saturation value of ground-state spin polarization, while the total time required for the polarization process remains constant. Additionally, the spin readout noise does not improve monotonically with decreasing excitation pulse duration; instead, it initially decreases and subsequently increases as the pulse duration varies. The spin readout noise reaches its optimal level when the pulse duration is 3 ns. Furthermore, no positive correlation exists between the signal-to-noise ratio (SNR) and the Purcell factor, and there is also an optimal value for SNR. When the pulse duration ranges from 1 ns to 40 ns, the variation in SNR is relatively insignificant. This research offers a novel perspective for enhancing the performance of quantum sensing based on diamond defects, such as nitrogen-vacancy (NV) centers.
The nitrogen-vacancy (NV) defect center in diamond shows great promise for many applications in quantum information processing and precision sensing. The NV center naturally occurs in two different charge states (NV0 and NV-), which have very different optical and spin properties. Understanding laser-induced switching between these charge states is essential for taking advantage of the NV center's properties in many contexts. Reducing the amount of optically-induced ionization is often important for increasing SNR and spin-coherence times. On the other hand charge state switching can be taken advantage of through spin-to-charge conversion techniques, enhancing optical spin-state readout of the NV center [1].A method for charge state initialization and readout using yellow (594 nm) laser illumination was used to investigate the ionization and recombination processes from other laser sources. The commonly used CW green (532 nm) laser was found to follow a simple two-level process at low powers while deviation occurred at higher powers, resulting in an unexpected peak in NV- population. This unexpected behaviour was found to be associated with an unknown process relaxing in the dark with a lifetime of 8.8 ± 0.6 µs. A spin-dependence in ionization was also observed due to the reduced ionization rate out of the metastable singlet state in NV- at this wavelength.Pulsed green (531 nm) and red (766 nm) illumination were used to study the charge state dynamics during excitation and depletion processes. Red illumination is known to cause depletion of NV- fluorescence, but it was initially unclear how much of this reduction is due to stimulated emission and how much is from charge state ionization, as both are non-radiative processes. By simultaneously modeling the measured excitation, fluorescence depletion, and charge state switching of the pulsed lasers, we were able to quantitatively extract the relative rates of excitation, ionization, and stimulated emission for the two colors of pulsed laser. The models developed through these measurements were used to calculate the amount of expected spin-polarization after a single excitation then depletion pulse sequence. These results have implications for stimulated emission depletion (STED) microscopy [2], laser threshold magnetometry [3] and spin to charge conversion [1,4].