Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2506.15439

Satellite Signal Detection via Rydberg-Atom Receiver

Mignwei Lei, Zhang, Jianquan, Luo, Qun, Zhentao Zhang, Ming Wang, Meng Shi

Published Jun 18, 2025• 0 citations
arXivHTMLPDF

Abstract

Rydberg-atom receivers aim for ultra-high sensitivity to microwave fields through various techniques, but receiving satellite signals has remained a significant challenge, due to the difficulty of capturing weak microwaves over long distances. In this work, we introduce a high-gain antenna to focus satellite signals, and then apply into an atomic cell via a microwave cavity. Using microwave-enhanced coupling, the minimum detectable power of incident microwave is down to -128 dBm, and the corresponding sensitivity is estimated as 21 nV/cm/Hz1/2 at frequency of 3.80 GHz. Furthermore, beacon signal from geostationary satellites is captured with Rydberg sensors for the first time, without the need for a low-noise amplifier. And C-band modulated signals are read out with a signal-to-noise ratio of 8 dB. Our results mark a significant breakthrough in facilitating satellite communications using Rydberg-atom receivers.

DOI
10.48550/arxiv.2506.15439

Related papers

Satellite Microwave Detection via Cavity-Coupled Rydberg Atomic Receiver

Mingwei Lei, Meng Shi

Due to the small interaction region between Rydberg atoms and the microwave field, it is difficult to detect weak satellite signals using free-space-coupled atomic receivers. In this work, we introduce a cavity-coupled Rydberg atomic receiver to enhance the microwave field and combine it with a passive antenna to detect C-band satellite signals. Using microwave-atom enhanced coupling, the minimum detectable power of incident microwave is reduced to -128 dBm, and the corresponding sensitivity sensing by atoms is estimated as 21 nV/cm/Hz1/2at a frequency of 3.80 GHz. Furthermore, we also show the effectiveness of this scheme by capturing the beacon signal from a geostationary satellite, without the need for low-noise amplifiers often used in conventional detection. Besides, modulated satellite signals are received with a signal-to-noise ratio of 8 dB with a measurement bandwidth of 10 Hz. Our results demonstrate an advancement in facilitating satellite communications using cavity-coupled Rydberg-atom receivers.

IEEE Transactions on Quantum Engineering•Jan 1, 2026•1 citation

Sensitivity Enhancement of S-Band Rydberg Atom Microwave Receiver Using Resonant Cavity

Yipeng Xie, Xinbing Chen, Mingwei Lei +1 more

Rydberg atom-based microwave electric field sensing has attracted growing interest owing to its inherent advantages, such as absolute calibration, wideband operability, and compatibility with room-temperature devices. A critical bottleneck that limits sensitivity is the inefficient coupling between the Rydberg atoms and the incident microwave field, particularly when detecting weak signals propagating in free space. Here we propose and experimentally validate a scheme that integrates a horn antenna with a resonant microwave cavity to significantly improve this coupling for free-space signal reception in the S-band. Using a two-photon excitation scheme in a cesium vapor cell, we systematically characterize the sensing performance under three configurations: a bare cell, direct cavity injection, and a cavity coupled to a horn antenna that captures free-space microwave signals over a 1 m distance. In the antenna-coupled cavity configuration, we achieve an optimal sensitivity of 2.33 nV/cm/$\sqrt{\text{Hz}}$ at the receiving antenna, which corresponds to an enhancement of approximately 17.9 dB compared to the optimized bare vapor cell configuration. Our findings offer a practical and effective route to boost the sensitivity of Rydberg atomic sensors, facilitating their adoption in real-world microwave metrology and wireless communication applications where weak free-space electric fields must be reliably measured.

physics.atom-phCross-listedarXiv:2606.02669•Optics Express•Jun 2, 2026•0 citations

Cavity-Enhanced Rydberg Atom Microwave Receiver

Bang Liu, Lihua Zhang, Qifeng Wang +11 more

Abstract Developing microwave electric field sensing based on Rydberg atoms has received significant attention due to its unique advantages. However, achieving effective coupling between Rydberg atoms and the microwave electric field in the sensing process is a challenging problem that greatly impacts the sensitivity. To address this, we propose using a microwave resonant cavity to enhance the effective coupling between the Rydberg atoms and the microwave electric field. In our experiment, Rydberg atoms are prepared via a three-photon excitation scheme, and the electric fields are measured without and with a microwave cavity in which the vapor cell is placed inside, respectively. As a result, we achieved an 18 dB enhancement of power sensitivity by adding the cavity, which is an effective enhancement in electric field pulse signal detection. This experimental testing provides a promising direction for enhancing the sensitivity of Rydberg atomic electric field sensors and paves the way for their application in precision electric field measurements.

arXiv:2404.06915•Chinese Physics Letters•Apr 7, 2025•26 citations

Cavity-enhanced Rydberg atomic superheterodyne receiver

Yukang Liang, Qinxia Wang, Zhi‐Hui Wang +7 more

High-sensitivity measurements of the microwave electric field are important in applications of communication and metrology. The sensitivity of traditional Rydberg superheterodyne receivers in free space is effectively determined by the signal-to-noise ratio (SNR), which is often considered equivalent to sensitivity in practical sensing applications. In this work, we demonstrate a cavity-enhanced receiver, where an optical cavity significantly amplifies the interaction between the probe light and cesium atoms, which substantially improves the signal-to-noise ratio via enhancing the expansion coefficient κ . Here, κ is the edge slope of the single peak obtained by fitting the double-peak EIT-AT spectrum, characterizing the response of the probe light to the frequency detuning of the coupling laser. The sensitivity is thus boosted by a factor of approximately 19 dB. This study highlights the pivotal role of optical cavities in advancing Rydberg-based detection systems, offering a promising approach for high-sensitivity microwave electric field measurements.

arXiv:2502.20792•Optics Express•Mar 4, 2025•7 citations

High-Sensitivity Rydberg Atom-Based Field Sensing Enhancement Using Miniaturized Resonator

Aojie Zhou, Yi Lin, Ruiqi Mao +4 more

High-sensitivity amplitude and frequency detection of microwave electric fields is of significant importance in various fields, including communications, microwave quantum technology, aerospace, medicine, and meteorology. Rydberg atom-based sensors promise traceable standards and high sensitivity for detecting weak electric fields and enhancing sensing sensitivity, mainly by using superheterodyne technology and resonant structures. Detecting high-frequency (HF) band fields with high sensitivity using Rydberg atom sensors is a significant challenge due to the requirement of exciting atoms to extremely high energy states for resonant detection. We demonstrate the off-resonant Rydberg atomic superheterodyne architecture with additional resonators for greatly enhancing the sensing sensitivity to HF band fields. In this approach, we propose a miniaturized square spiral resonator with an electrical size of$0.011~\lambda $at 15.54 MHz. To reduce the electric-field-screening effect of the adsorption of alkali metal atoms, we use a monocrystalline sapphire cesium (Cs) vapor cell. By utilizing the off-resonant alternating current (ac) Stark effect, the initial sensitivity of the Rydberg atom sensor without the resonator is measured to be$10.39~\mu \text {V/cm}\sqrt {\text {Hz}}$at room temperature. With the addition of the miniaturized square spiral resonator, the sensitivity significantly improved to$2.60~\text {nV/cm}\sqrt {\text {Hz}}$, which has been inaccessible so far with atomic sensors. Here, we provide an enhancement of 72 dB, which is three orders of magnitude improvement in sensitivity than when the resonator is not used. This enhancement resonator extends Rydberg atomic high-sensitivity sensing to the HF band and shows great potential, especially in shortwave radio reception.

IEEE Transactions on Antennas and Propagation•Aug 13, 2025•9 citations

Enhancing sensitivity of atomic microwave receiver combining laser arrays

Bo Wu, Ruiqi Mao, Liu, Yi +5 more

Rydberg atom,which exhibits a strong response to weak electric(E) fields,is regarded as a promising atomic receiver to surpass sensitivity of conventional receivers. However, its sensitivity is strongly limited by the noise coming from both classical and quantum levels and how to enhance it significantly remains challenging. Here we experimentally prove that the sensitivity of Rydberg atomic receiver can be increased to 23 nV/cm/Hz1/2 by combining laser arrays. Theoretically, we demonstrate that multiple beams illuminating on a PD perform better than multiple PDs for laser arrays.In our experiment,10 dB SNR enhancement is achieved by utilizing 2 * 2 probe beam arrays, compared to the performance of a laser beam,and it can be enhanced further just by adding a resonator. The results could offer an avenue for the design and optimization of ultrahigh-sensitivity Rydberg atomic receivers and promote applications in cosmology, meteorology, communication, and microwave quantum technology.

arXiv:2403.14132•Mar 21, 2024•0 citations
Rydberg-atom receivers aim for ultra-high sensitivity to microwave fields through various techniques, but receiving satellite signals has remained a significant challenge, due to the difficulty of capturing weak microwaves over long distances. In this work, we introduce a high-gain antenna to focus satellite signals, and then apply into an atomic cell via a microwave cavity. Using microwave-enhanced coupling, the minimum detectable power of incident microwave is down to -128 dBm, and the corresponding sensitivity is estimated as 21 nV/cm/Hz1/2 at frequency of 3.80 GHz. Furthermore, beacon signal from geostationary satellites is captured with Rydberg sensors for the first time, without the need for a low-noise amplifier. And C-band modulated signals are read out with a signal-to-noise ratio of 8 dB. Our results mark a significant breakthrough in facilitating satellite communications using Rydberg-atom receivers.
Due to the small interaction region between Rydberg atoms and the microwave field, it is difficult to detect weak satellite signals using free-space-coupled atomic receivers. In this work, we introduce a cavity-coupled Rydberg atomic receiver to enhance the microwave field and combine it with a passive antenna to detect C-band satellite signals. Using microwave-atom enhanced coupling, the minimum detectable power of incident microwave is reduced to -128 dBm, and the corresponding sensitivity sensing by atoms is estimated as 21 nV/cm/Hz1/2at a frequency of 3.80 GHz. Furthermore, we also show the effectiveness of this scheme by capturing the beacon signal from a geostationary satellite, without the need for low-noise amplifiers often used in conventional detection. Besides, modulated satellite signals are received with a signal-to-noise ratio of 8 dB with a measurement bandwidth of 10 Hz. Our results demonstrate an advancement in facilitating satellite communications using cavity-coupled Rydberg-atom receivers.
Rydberg atom-based microwave electric field sensing has attracted growing interest owing to its inherent advantages, such as absolute calibration, wideband operability, and compatibility with room-temperature devices. A critical bottleneck that limits sensitivity is the inefficient coupling between the Rydberg atoms and the incident microwave field, particularly when detecting weak signals propagating in free space. Here we propose and experimentally validate a scheme that integrates a horn antenna with a resonant microwave cavity to significantly improve this coupling for free-space signal reception in the S-band. Using a two-photon excitation scheme in a cesium vapor cell, we systematically characterize the sensing performance under three configurations: a bare cell, direct cavity injection, and a cavity coupled to a horn antenna that captures free-space microwave signals over a 1 m distance. In the antenna-coupled cavity configuration, we achieve an optimal sensitivity of 2.33 nV/cm/Hz\sqrt{\text{Hz}}Hz​ at the receiving antenna, which corresponds to an enhancement of approximately 17.9 dB compared to the optimized bare vapor cell configuration. Our findings offer a practical and effective route to boost the sensitivity of Rydberg atomic sensors, facilitating their adoption in real-world microwave metrology and wireless communication applications where weak free-space electric fields must be reliably measured.
Abstract Developing microwave electric field sensing based on Rydberg atoms has received significant attention due to its unique advantages. However, achieving effective coupling between Rydberg atoms and the microwave electric field in the sensing process is a challenging problem that greatly impacts the sensitivity. To address this, we propose using a microwave resonant cavity to enhance the effective coupling between the Rydberg atoms and the microwave electric field. In our experiment, Rydberg atoms are prepared via a three-photon excitation scheme, and the electric fields are measured without and with a microwave cavity in which the vapor cell is placed inside, respectively. As a result, we achieved an 18 dB enhancement of power sensitivity by adding the cavity, which is an effective enhancement in electric field pulse signal detection. This experimental testing provides a promising direction for enhancing the sensitivity of Rydberg atomic electric field sensors and paves the way for their application in precision electric field measurements.
High-sensitivity measurements of the microwave electric field are important in applications of communication and metrology. The sensitivity of traditional Rydberg superheterodyne receivers in free space is effectively determined by the signal-to-noise ratio (SNR), which is often considered equivalent to sensitivity in practical sensing applications. In this work, we demonstrate a cavity-enhanced receiver, where an optical cavity significantly amplifies the interaction between the probe light and cesium atoms, which substantially improves the signal-to-noise ratio via enhancing the expansion coefficient κ . Here, κ is the edge slope of the single peak obtained by fitting the double-peak EIT-AT spectrum, characterizing the response of the probe light to the frequency detuning of the coupling laser. The sensitivity is thus boosted by a factor of approximately 19 dB. This study highlights the pivotal role of optical cavities in advancing Rydberg-based detection systems, offering a promising approach for high-sensitivity microwave electric field measurements.
High-sensitivity amplitude and frequency detection of microwave electric fields is of significant importance in various fields, including communications, microwave quantum technology, aerospace, medicine, and meteorology. Rydberg atom-based sensors promise traceable standards and high sensitivity for detecting weak electric fields and enhancing sensing sensitivity, mainly by using superheterodyne technology and resonant structures. Detecting high-frequency (HF) band fields with high sensitivity using Rydberg atom sensors is a significant challenge due to the requirement of exciting atoms to extremely high energy states for resonant detection. We demonstrate the off-resonant Rydberg atomic superheterodyne architecture with additional resonators for greatly enhancing the sensing sensitivity to HF band fields. In this approach, we propose a miniaturized square spiral resonator with an electrical size of$0.011~\lambda $at 15.54 MHz. To reduce the electric-field-screening effect of the adsorption of alkali metal atoms, we use a monocrystalline sapphire cesium (Cs) vapor cell. By utilizing the off-resonant alternating current (ac) Stark effect, the initial sensitivity of the Rydberg atom sensor without the resonator is measured to be10.39 μV/cmHz10.39~\mu \text {V/cm}\sqrt {\text {Hz}}10.39 μV/cmHz​at room temperature. With the addition of the miniaturized square spiral resonator, the sensitivity significantly improved to2.60 nV/cmHz2.60~\text {nV/cm}\sqrt {\text {Hz}}2.60 nV/cmHz​, which has been inaccessible so far with atomic sensors. Here, we provide an enhancement of 72 dB, which is three orders of magnitude improvement in sensitivity than when the resonator is not used. This enhancement resonator extends Rydberg atomic high-sensitivity sensing to the HF band and shows great potential, especially in shortwave radio reception.
Rydberg atom,which exhibits a strong response to weak electric(E) fields,is regarded as a promising atomic receiver to surpass sensitivity of conventional receivers. However, its sensitivity is strongly limited by the noise coming from both classical and quantum levels and how to enhance it significantly remains challenging. Here we experimentally prove that the sensitivity of Rydberg atomic receiver can be increased to 23 nV/cm/Hz1/2 by combining laser arrays. Theoretically, we demonstrate that multiple beams illuminating on a PD perform better than multiple PDs for laser arrays.In our experiment,10 dB SNR enhancement is achieved by utilizing 2 * 2 probe beam arrays, compared to the performance of a laser beam,and it can be enhanced further just by adding a resonator. The results could offer an avenue for the design and optimization of ultrahigh-sensitivity Rydberg atomic receivers and promote applications in cosmology, meteorology, communication, and microwave quantum technology.